Drill/driver Overload
This drill/driver is fitted with an overload protection. If the drill/driver is excessively forced,
or the task being performed is too great for the drill/driver, the drill/driver will automatically
go into an overload mode. When the drill/driver goes into overload, the drill/driver will
automatically and suddenly STOP. To reset the overload, simply release the trigger. When the
trigger is pressed again, the drill/driver will restart. Resume work after the overload has been
reset, but reduce the load by using a smaller drill bit or re-sharpen the existing drill bit and
reduce the amount of force placed on the drill/driver. If the drill/driver is set to HIGH speed on
the gear selector, consider changing to LOW speed selection.
CAUTION! Do not continue to overload the drill and constantly reset the overload. Doing
this will cause the battery cells to overheat.
Temperature Cut Out
If the drill/driver is constantly overloaded, or the drill/driver is used constantly at maximum
rating in high temperatures, the battery cells may overheat causing the battery pack to shut
down.
When this occurs you will need to immediately stop drilling and allow the battery cells to
reduce in temperature.
Note The drill/driver will not restart until the battery pack has cooled.
To reduce the temperature of the cells remove the battery pack from the drill/driver and place
the battery pack in a free air environment, out of direct sunlight or any other heat source.
DO NOT force-cool the pack in any way. Do not place in refrigerators or freezers.
When the battery pack has cooled down it can again be used to operate the drill/driver,
as long as the load or the conditions causing the original excessive temperature has been
corrected.