598871
10
Verklein
Vergroot
Pagina terug
1/16
Pagina verder
1817
MASSAGING (WHOLE BODY SENSOR AUTOMATIC COURSE)
7
Adjust the strength of massage. (See page 18)
Massages according to the stiffness.
Adjusts the operation and strength of standard massaging
according to the measured degree of stiffness.
Massaging operation and the display of remote control.
(See page 18)
Finishes the massaging automatically by timer operation.
Massaging rollers are moved to the upper position, and stop massaging automatically.
The buzzer sounds and the lamp on the remote control will turn off.
The massaging time differs according to the detected stiffness, but the maximum is
approx. 20 minutes.
6
Starts massaging automatically.
Measure the position of shoulder.
Start sensor massage.
Measures the degree of stiffness in each part of body with the
sensor and informs of the degree of stiffness.
Massaging operation and the display of remote control.
(See page 18)
Check if the position of shoulder is correct. If not, adjust the position using
the POSITION ADJUST button. (See page18)
Explanation with an example of STIFFNESS
SENSOR MASSAGE
Massaging according to the degree of stiffness
Displays the position where the
stiffness has been detected.
Shiatsu massaging
Massage in relaxed condition as much as possible during massage. The degree of stiffness may
not be measured correctly when the user is given stimulation other than sensor massage.
Examples of this are if the user massages immediately after taking a bath or while watching TV.
The measurement result indicates the stiffness according to the body's biological reaction (the
amount of perspiration from fingers or plus) to the sensor massage, so it may differ from the
stiffness the user actually feels.
NOTE
If you have felt abnormal physical sensation or want to stop the massager immediately
To stop the massage during massaging operation.
Press the OPERATION ON/OFF button.
The massaging that corresponds to the pressed
button will stop.
(The Massaging rollers will stop at that point.)
All the massaging will stop and the chair will be
automatically brought to its home position.
(The massaging rollers are moved to the upper
position and remain in that position.)
Press the INSTANT STOP button.
All the massaging will stop and the lamp of the remote control
will turn off.
When you want to restart massaging, press the OPERATION
ON/OFF button. (The massaging rollers move to the upper
position and remain in that position.)
After the movement, repeat the operation from the beginning
of each massage.
Press the button for the current operation.
If you continue to press the "WEAK ( )" button until the illumination of the
lower body strength scale turns off, you can turn off the massaging of the
lower body. If you press the "STRONG ( )" button, the massaging will resume.
When adjusting the strength of massage
When it is felt that the massaging on the soles or calves is too strong even when setting the
strength of lower body (air) massaging to "weak," put a towel etc. on those massaged parts.
NOTE
Displays the aim of massaging positions, the type
of massaging, the stiffness, body pressure and the
remaining massaging time on the remote control.
Massaging operation and display of remote control
Each time the UPPER BODY STRENGTH ADJUST button is pressed,
the strength of upper body massaging can be adjusted in five stages.
(The strength is displayed by the lamp on the remote control.)
Each time the LOWER BODY STRENGTH ADJUST button is pressed,
the strength of lower body massaging (air) can be adjusted in three stages.
(The strength is displayed by the lamp on the remote control.)
Measure the position of shoulder and
match the position of massaging rollers
to that of shoulder.
Measurement of shoulder position
Massaging rollers move up and down
to measure the position of shoulder.
(Sit deeply on the massage chair and raise your
head slightly. The matching of the position of
shoulders may not be possible if the head is
leaning on the back rest.)
Massaging operation at recognized
position of shoulder.
Check that massaging rollers match
the position of your shoulder.
If not, when the lamp of is
flickering (a buzzer sounds),
adjust the position by pressing
the POSITION ADJUST button.
The massaging rollers are
moved up or down by 1cm
each time the POSITION
ADJUST button is pressed.
When it is difficult to
adjust with POSITION
ADJUST button, move
your body for adjustment.
The height that can be
adjusted is between
approx. 150cm to 180cm.
Decides the position of shoulder.
Position too high
Position too low
Appropriate position
Massaging
rollers
(Remote control display)
Measurement of the degree of stiffness.
The sensor will display the positions of stiffness (those
where stiffness has been felt) by measuring the amount
of perspiration from fingers and pulse in reaction to
sensor massage.
When measuring the degree of stiffness, the result is
displayed by the ring around the REPEAT! (See page 7)
When the measurement is over, a buzzer sounds.
Downloaded from www.Manualslib.com manuals search engine
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sanyo HEC-DR7700 Massager Chair bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sanyo HEC-DR7700 Massager Chair in de taal/talen: Engels als bijlage per email.

De handleiding is 2,67 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info