4. FUNCTIONING
After setting the DIP-SWITCHES of the charger, by connecting the device to the
battery and to the mains, it signals the operating status with LEDs of different colors.
According to the model there could be 3 or 5 LED indicators, as shown in the
following pictures:
The LEDs on the charger give the following indications:
Battery charger with 3 LEDs
LED status Indication
Constant or
flashing RED
Battery with inverted poles or
too high voltage
Constant
YELLOW
On charge
Flashing
YELLOW
Battery disconnected or too low
voltage
Constant
GREEN
Battery charged
Battery charger with 5 LEDs
LED status Indication
Flashing RED Battery with too high voltage
Constant RED Battery with inverted poles
Constant ORANGE Battery disconnected
Flashing ORANGE Self-diagnosis of the charger failed
Constant ORANGE +
YELLOW
On charge
Constant YELLOW Capacity of the battery on charge
Constant GREEN Full-loaded battery
5
PF2405S – 24V 5A
Description Technical Features
Input voltage 100VAC – 240VAC ±10% Universal
Frequency 50Hz - 60Hz
Output - Boost Charge 28,8V (2,4V/Cell)
Output - Float Charge 27V - 27,8V (2,27V/Cell)
Output current 5A ±0,5A
Short-circuit protection Auto reset at the end of short-circuit condition
Reverse polarity protection Auto reset at the end of reverse polarity condition
Additional protections Safe connection without sparkles on output and input
Thermal protection against overtemperature
Dimensions L106 x W128 x H56 mm
Weight 0,9 kg (cables excluded)
PF2408 – 24V 8A
Description Technical Features
Input voltage 100VAC – 240VAC ±10% Universal
Frequency 50Hz - 60Hz
Output - Boost Charge 28,8V (2,4V/Cell)
Output - Float Charge 27V - 27,8V (2,27V/Cell)
Output current 8A ±0,5A
Short-circuit protection Auto reset at the end of short-circuit condition
Reverse polarity protection Auto reset at the end of reverse polarity condition
Additional protections Safe connection without sparkles on output and input
Thermal protection against overtemperature
Dimensions L190 x W145 x H65 mm
Weight 1,7 kg (cables excluded)