PFC1200-24CH30S – 24V 30A
Description Technical Features
Input voltage 100VAC – 240VAC ±10% Universal
Frequency 50Hz - 60Hz
Output - Boost Charge 28,8V (2,4V/Cell)
Output - Float Charge 27V - 27,8V (2,27V/Cell)
Output current 30A ±0,5A
Short-circuit protection Auto reset at the end of short-circuit condition
Reverse polarity protection Auto reset at the end of reverse polarity condition
Additional protections Safe connection without sparkles on output and input
Thermal protection against overtemperature
Dimensions L280 x W134 x H77.2 mm
Weight 3,13kg (cables excluded)
PF36CH25S – 36V 25A
Description Technical Features
Input voltage 100VAC – 240VAC ±10% Universal
Frequency 50Hz - 60Hz
Output - Boost Charge 43,2V (2,4V/Cell)
Output - Float Charge 40,5V – 41,7V (2,27V/Cell)
Output current 25A ±0,5A
Short-circuit protection Auto reset at the end of short-circuit condition
Reverse polarity protection Auto reset at the end of reverse polarity condition
Additional protections Safe connection without sparkles on output and input
Thermal protection against overtemperature
Dimensions L280 x W134 x H77.2 mm
Weight 3,13kg (cables excluded)
13
1. INTRODUCTION
This manual contains important operating and safety instructions, please read and
understand it before using the device.
1.1 SAFETY NOTES
– Before each use please check the battery charger, the connection cable and the
connector. If any malfunction is detected do not use it! It is strictly forbidden to
open the device. Repairs may only be carried out by qualified technicians using
original spare parts. A charger, a cable and / or a damaged connector increases
the risk of fatal electric shocks.
– Do not place the charger on highly flammable surfaces or environments (ex .:
paper, cloth etc ...). The overheating of the device during the charging phases
can increase the risk of fire.
– During operation the device should be placed in a well-ventilated place.
– If the power supply cable is damaged it must be replaced by a qualified
technician to eliminate the risk of accidents.
1.2 WARNING
– NEVER charge a cold or non-rechargeable battery!
– Keep the device out of the reach of children
– The device must be protected from sunlight or direct heat sources to prevent
overheating.
– To reduce the risk of malfunctions do not block the ventilation bores.
– DO NOT install the unit in a sealed environment, otherwise it may overheat.
– To avoid the risk of electric shock and / or fire, make sure that the power
supply system is in good condition.
– DO NOT use the charger with damaged cables and / or with inadequate
section.
– DO NOT use the battery charger in an environment with high humidity or in
direct contact with splashes of water and / or other liquid or in the rain.