Press the On-/O-/M-Button
3
to end the treatment. Pressing the On-/O-/M-Button
3
again switches the de-
vice o.
The device has an automatic load detection at all set intensities above level 5. If the electrodes are not properly
applied to the skin or another connection problem appears, the device will automatically switch to level 0, while
the symbol „A“ or „B“ ashes. The device then switches back to standby mode.
If the battery voltage is too low, the „low battery“ symbol
t
ashes. Stop the application and replace the batteries.
Troubleshooting
Use of the electrodes
The supplied electrodes may only be used with the medisana TT 200 3-in-1 electro-therapy
device. Make sure that the device is switched o before applying and removing the electro-
des.
If you want to reposition the electrodes during the application, turn the device o rst.
The usage of electrodes may lead to skin irritations. If you experience such skin irritations,
e.g. redness, blistering or itching, discontinue using them. Do not use the stimulator per-
manently on the same body part, as this may also lead to skin irritations.
Never use the electrodes together with other people.
The electrodes must connect entirely to the skin surface to prevent hot spots, which may
lead to skin burns.
Do not use the electrode pads for more than 10 times, as connection between the electro-
des and the skin deteriorates over time.
The adhesive force of the electrodes depends on the skin properties, storage condition,
and the number of applications. If your electrode pads are no longer fully sticking to the
skin surface, replace them with new ones. Stick the electrode pads back onto the protec-
tive foil after use and store them in the storage bag to prevent them from drying out. This
retains the adhesive force for a longer period.
Before applying the electrode, it is recommended for users to wash and degrease the skin,
and then dry it.
Never remove the electrodes from the skin while the device is still on.
Use only original electrodes recommended by the manufacturer. Other electrodes could
cause injury.
Everyone reacts dierently to electrical nerve stimulation. There may be individual devi-
ations in the correct placement of the electrodes. Contact your doctor to nd out which
placement is best for you.
Do not use any adhesive electrodes with a size smaller than those the original manufactu-
rer attached. Otherwise the current density may be too high and cause injuries.
The size of the adhesive pads may not be changed, e.g. by clipping o parts.
Make sure that the area where the pain comes from is completely covered with the electro-
de pads. For painful muscle groups, all aected muscles must be reached by the electro-
des.
Notes on the TENS application
If you feel the output intensity too strong, you can press „-“ button
8
to decrease it;
If you don‘t feel any discomfort during the treatment, we advise you to use the device until
the session ends. Normally, the pain relief occurs after 5~10 mins of treatment;
We recommend 1 to 2 treatments per day and one week as period of treatment;
If pain relief is not achieved or the pain gets even worse after that period of treatment, ple-
ase consult your doctor.
Notes on the EMS application
Place the electrodes correctly as described in this manual;
We recommend 1 to 2 treatments per day and one week as period of treatment;
If you feel discomfort during treatment, you can either pause the session or decrease the
intensity of the output.
Maintenance and cleaning
To ensure a trouble-free and long-term functional safety of the device, the following points should be considered:
Remove the electrodes from the device and clean the device with a soft, slightly damp cloth. In case of heavier
dirt, you may also apply a mild detergent.
Protect the device from humidity. Do not hold the appliance under running water nor submerge it in water or
other liquids.
Do not place the device on hot surfaces and do not expose it to direct sunlight.
Clean the surface of the electrode pads with a slightly damp cloth. Make sure that the device has been switched
o before cleaning!
For hygienic reasons, each user should use his/her own set of electrodes.
Do not use aggressive substances or chemical cleaners to clean the device.
Make sure that no liquid penetrates into the device. Do not use the device until it has completely dried.
Never clean the device during operation. Before cleaning, make sure that the device is switched o and the
batteries have been removed!
Maintenance
The manufacturer can not be held responsible for damage caused by unauthorized repairs. If your device has
a technical problem, contact the customer service.
Do not try to do repairs on your own.
Opening the device will void the warranty.
Your device has been tested before sale and requires no calibration or regular maintenance. If you have any
questions, please contact the customer service.
Problem Possible reasons Countermeasures
No display after
replacing the batteries.
Batteries not inserted correctly or
foreign matter in the battery com-
partment.
Battery type may be wrong.
1. Check and clean the compartment.
2. Insert new batteries of the correct type.
Pay attention to the correct polarity!
No or too
weak stimulation
- Electrodes not correctly positioned
on the skin
- Connection to the device is not
optimal
- Used batteries
- Too dry skin
1. Check that the electrodes have been
correctly placed on the skin and that the
cable connection to the device is optimal.
2. Replace the batteries.
3. Wipe your skin and the electrodes with a
damp cotton cloth.
The skin tickles or
burns during the
application
- Application time too long.
- Electrodes are not placed
correctly on the skin or the contact
is not optimal
- The skin is hypersensitive
1. Apply once a day and shorten the period
of use.
2. Check that the electrodes are correctly
applied to the skin.
3. Wipe o your skin and electrodes with a
damp cotton cloth.
4. For hypersensitive skin consult your
doctor.
The device stops
during the
application
- Electrodes are not placed
correctly on the skin or the contact
is not optimal
- Used batteries
1. Check that the electrodes are correctly
applied to the skin.
2. Replace the batteries.
Storage
Turn o the device and remove the cables. Place the electrodes on the carrier foil and package them together
with the device and the cables in their original packaging. Observe the storage conditions in the technical data!
If you do not use the device for a long time, remove the batteries from the battery compartment.
Program tables
Mode
Part of the
body
Frequency
Hz
Impulse
width µs
Therapy duration
min.
Curve form
Neck 80-120 120-100
Default: 30
Adjustable: 5-90
Modulation
Shoulder 80-100 100
Default: 30
Adjustable: 5-90
Modulation
Arm 2-60 260-160
Default: 30
Adjustable: 5-90
Modulation
Hand 100 100
Default: 30
Adjustable: 5-90
Continue
Back
60/50/45/10
/50/35
200
Default: 30
Adjustable: 5-90
Modulation
Abdomen 120 55
Default: 30
Adjustable: 5-90
Continue
Hip 100 150
Default: 30
Adjustable: 5-90
Burst
Leg 40/6/50 250
Default: 30
Adjustable: 5-90
Modulation
Foot 80-120 100-120
Default: 30
Adjustable: 5-90
Modulation
Joints 120 100-120
Default: 30
Adjustable: 5-90
Modulation
Neck 30 200
Default: 30
Adjustable: 5-90
Synchronous
Shoulder 45 200
Default: 30
Adjustable: 5-90
Synchronous
Arm 50 150
Default: 30
Adjustable: 5-90
Synchronous
Hand 4 200
Default: 30
Adjustable: 5-90
Synchronous
Back 60 200
Default: 30
Adjustable: 5-90
Synchronous
Abdomen 20 200
Default: 30
Adjustable: 5-90
Synchronous
Hip 30 150
Default: 30
Adjustable: 5-90
Synchronous
Leg 80 200
Default: 30
Adjustable: 5-90
Synchronous
Foot 20 200
Default: 30
Adjustable: 5-90
Synchronous
Knead 28-44 120~250 30 Modulation
Rub 25-79 120~250 30 Modulation
Tap 49-97 100~240 30 Modulation
TENS
EMS
MASSAGE
Disposal
This device may not be disposed of in the household garbage. Every consumer is required by
law to dispose of electric or electronic equipment, regardless whether or not they contain
hazardous substances at a collection point in his/her city or at the retail outlet so that they can
be disposed of in an environmentally-friendly manner.
Remove the batteries before you dispose of the unit. Do not dispose of used batteries in the
household garbage, instead dispose of them as special waste or at a battery collection point in
a specialist outlet. Contact your local administration or vendor with respect to disposal.
Accessories
Cable set - article number 88359
8 self-adhesive electrodes - article number 88349
Technical specications
Name and model:
Model no.:
Power supply:
Channels:
Curve form:
Output:
Intensity:
Output precision:
Treatment modes:
Number of programs:
Impulse width:
Frequency:
Application time:
Automatic switch-o:
Operating conditions:
Storage conditions:
Dimensions approx.:
Size of electrode pads approx.:
Weight approx.:
Article no.:
EAN number:
medisana 3-in-1 Electro Therapy Device TT 200
R-C4B
3 x 1.5V , Micro batteries (AAA)
2
Bi-phase square-wave pulse
Max. 120mA (at 500 Ohm load)
0 to 40 levels, adjustable
±20% for all parameters
TENS, EMS and MASSAGE
TENS: 10; EMS: 9; MASSAGE: 3
55 - 260 μs, depending on the program
2 – 120 Hz, depending on the program
5 - 90 minutes, adjustable, depending on the program
after 1 minute
+5°C to +40°C at 15% to 93% rel. humidity,
atmospheric pressure from 700 hPa to 1060 hPa
-10°C to +55°C at 10% to 95% rel. humidity,
atmospheric pressure from 700 hPa to 1060 hPa
109 x 54.5 x 23 mm
50 x 50 mm
76 g
88347
4001690 88347 4
The current version of this instruction manual can be found under www.medisana.com
In accordance with our policy of continual product improvement, we reserve the right to make technical and
visual changes without notice.
Warranty and repair terms
Please contact your dealer or the service centre in case of a claim under the warranty. If you have to return the
unit, please enclose a copy of your receipt and state what the defect is.
The following warranty terms apply:
1. The warranty period for medisana products is three years from date of purchase. In case of a warranty
claim, the date of purchase has to be proven by means of the sales receipt or invoice.
2. Defects in material or workmanship will be removed free of charge within the warranty period.
3. Repairs under warranty do not extend the warranty period either for the unit or for the replacement parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. non-observance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the consumer or during transport
to the service centre.
d. Accessories which are subject to normal wear and tear.
5. Liability for direct or indirect consequential losses caused by the unit are excluded even if the damage to
the unit is accepted as a warranty claim.
Shenzhen Roundwhale Technology Co., Ltd.
Add: 202, 2/F, Building 27, Dafa Industrial Park, longxi community,
longgang street, longgang district, Shenzhen, China.
Email: info@roovjoy.com
Shanghai International Holding Corp. GmbH (Europe)
Address: Eiestr. 80, 20537 Hamburg, Germany
imported & distributed by:
medisana GmbH, Jagenbergstr. 19, 41468 NEUSS, GERMANY
The service centre address is shown on the attached leaet.
EC REP
GB
GB
Instruction manual
3-in-1 Electro Therapy Device TT 200
Device and controls
IMPORTANT
Non-observance of these instructions
can result in serious injury or damage
to the device.
WARNING
These warning notes must be observed
to prevent any injury to the user.
CAUTION
These notes must be observed to pre-
vent any damage to the device.
NOTE
These notes give you useful additional
information on the installation or opera-
tion.
Device classication: Type BF
LOT number
Protection rating against foreign objects
and water
Authorized representative in the EC
Manufacturer
Date of manufacture
Explanation of symbols
IP22
2460
EC REP
1
2
3
4
5
6
7
8
9
0
q
w
e
r
t
z
u
i
o
p
a s d
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Medisana TT 200 - 88347 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Medisana TT 200 - 88347 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 3,99 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info