8. Initial operation
8.5 Express programming
Test run (only necessary after resetting)
Before carrying out the express programming procedure,
the drive system (with the gate coupled up) must be
driven to the factory default OPEN and CLOSED gate
positions using the (+) and (-) buttons.
• Carry out a test run (MASTER and SLAVE).
Express programming
The basic functions of the operator system are set
during the express programming procedure.
MASTER:
- Gate position GATE OPEN
- Gate position GATE CLOSED
- Remote controls
SLAVE (only for double wing gates):
- Gate position GATE OPEN
- Gate position GATE CLOSED
The programming procedure is a consecutive process.
It is essential that this procedure be carried out.
After express programming has been completed and a
learning run has been carried out to set the automatic
cut-out at the OPEN and CLOSED gate positions, the
operator system is ready for operation.
8.5.1 General notes on express programming
Advice:
When programming the OPEN and
CLOSED gate positions, the reference
point must be passed.
8.5.2 Programming buttons
The controls are programmed using the plus (+),
minus (-) and (P) buttons.
If no buttons are pressed within 120 seconds while in
programming mode, the controls revert to operating
mode.
A corresponding message is displayed.
Reference:
The messages are explained in
Section 10.
Advice:
For proper initial operation of the
operator system, the express
programming procedure must be
carried out.
• Carry out the express programming according to the
following procedure.
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
30 Operating Instructions, Comfort 580 GB (#91636)