English Page 76
H. Connection of the operator
Advice:
- If CES is connected:
- CES CLOSE function is always active.
- CES OPEN function is learned when end position is
programmed.
- If several contact bars in the same travel direction are
connected, they have to be connected in series.
F Circuit board CES resistance evaluation (Art.-No.: 48069) CLOSE
G Circuit board CES resistance evaluation (Art.-No.: 48069) OPEN
H1 LED green Display of function
- glows when ready for operation
H2 LED yellow Display of error
- glows when contact bar is interrupted or at faulty end
resistance
H3 LED red Display of error
- glows when closing edge safety device is actuated
and when cut-out due to testing function
H4 LED yellow Display of function (for Pos. G without function)
- glows when static current circuit is closed
X30 System socket
H Circuit board comb. - CES OPEN / CLOSE (Art.-No.: 46143)
S1 Selector switch for static current circuit (stop function)
- if existing, normal position: Z
A: Connection of stop function via X32 or X32A
Z: Connection of stop function via X30 oder X30A
X30 Input closing edge safety device CLOSE system socket
X30A Input closing edge safety device CLOSE screw terminals
X31 Exit CES – signal OPEN and CLOSE system socket
X32 Input closing edge safety device OPEN system socket
X32A Input closing edge safety device OPEN screw terminals
I System cable 6 pol.
K Connection to control unit (system cable 6 pol.)
L Operator / control unit with connection socket for CES OPEN and CLOSE
M Short-circuit bridge (remove it by all means, if S6 is connected!)
S6 Switch for STOP – function (wicket door contact or similar) if existing
X1 Connecting terminals on door leaf
English Page 17
E. Hand transmitter
GB
Hand transmitter - Operation and accessories
A Battery - transmission control light
B Operating buttons
C Battery cover
D Battery 3V CR 2032
E Coding plug
• Please open the cover to change or insert the battery.
Observe right poling when changing the battery (fig. E.2).
13
Caution!
- Only operate the hand transmitter after you have made sure
that there are neither persons nor objects in the operating
range of the door.
- Children are not allowed to play with hand transmitters!
Advice:
Batteries are excluded from warranty.
Fixing accessories for hand transmitter:
Attachment clip, suitable to fix the hand transmitter to a visor
in the car (fig. E.3).