D. Installation
Operational check:
After the operator has been mounted, the following tests have to
be carried out:
- In 'close' direction the door runs against an obstacle of 50 mm
that lies on the floor:
-> The door has to reverse.
For operators for doors with openings in the door wing
(diameter of the opening > 50 mm):
- A load of 20 kg is put to the middle of the bottom door edge:
-> The door stops as soon as the open command is given.
Separate door from operator
• Pull the cable (A) downward to the stop in order to separate the door
from the operator (Fig. D.22).
Connect door and operator again
• Push the red release pin (B) back in the direction of the arrow (D.24).
• Start the door operator.
The symbols on the downward side of the carriage show the actual situation:
The door is separated from the operator.
->The front edge of the movable slide element (C) is above the arrow
of the symbol 'lock open' (fig. D.23).
The door is connected to the operator or will be connected automatically
after the next door travel.
->The front edge of the movable slide element (C) is above the arrow
of the symbol 'lock closed' (fig. D.24).
GB
English Page 77
I. Connection and initial operation of the extension units
Travel limit signals (relay)
Function: As soon as the end-of-travel position DOOR OPEN / DOOR CLOSED
is reached, the respective relay switches.
Connection of the relay circuit board (Art.No. 153 044)
34
Attention!
Please always plug on the flat cable plug in such a way, that the
cable is bent in direction of the edge of circuit board!
• Connect relay circuit board and control unit by means of enclosed flat cable.
Relay circuit board: Plug connection X4
Control unit: Plug connection X8a (33)
Detailed wiring diagram travel limit signals (relay):
Legend:
D1 Control light DOOR CLOSED
D2 Control light DOOR OPEN
H1 Signal light DOOR CLOSED
H2 Signal light DOOR OPEN
K1 Relay DOOR CLOSED
K2 Relay DOOR OPEN
Plug connections:
X4 Relay control
X8a Travel limit relay
(in control unit)