English Page 84
M. Technical details
Garage door operator
Comfort 257
Connected loads:
230 V
250 W (operation with lighting)
3,9 W (at standstill without lighting)
Door travel speed:
0,14 m/s
0,08 m/s
Push and pull force:
700 N / 1.000 N
Excess travel stop:
88 sec.
Lighting
1 x 40 W, E14,
Automatic closing timer:
with additional signal lights and
driveway photocell
Warning time can be set from 2 to
70 sec.
Open time can be set from
5 - 255 sec.
Control voltage:
Low voltage below 24 V DC.
Automatic cut-out:
Electronic power limit through
microprocessor and voltage sensor.
Anti-block system:
Through microprocessor
and rpm sensor.
Device to prevent forced opening
of door:
Through microprocessor
and rpm-sensor.
Protection category:
Only for dry buildings.
English Page 9
D. Installation
GB
Connect boom with the operator unit
• Push the adapter sleeve (A) to the stop onto the fine toothed gear shaft
(fig. D.3).
If you turn the operator unit by 90°, the installation depth is lessened by
150 mm. For this the reference point switch (B) has to be turned as well to
the foreseen position (fig. D.4).
• Put the boom in its right position to the adapter sleeve.
• Align the boom laterally.
• Push the boom onto the operator unit using slight pressure (fig. D.5).
4
Attention!
Do not use force!
If the boom is aligned parallel to the surface of the operator unit,
a short pull on the carriage is sufficient to lower the boom onto
the operator unit without force.
• Screw the boom to the operator unit using two clamp brackets (C) and
four hex screws SW 8 (D) (fig. D.6).
Mount suspension clamp to boom
• Mount the suspension clamp to the boom (for function and position of the
suspension clamp please look up point 3).
5