English Page 82
K. Error numbers
Error 6:
Photocell is active.
Error 7:
Programming cancelled.
Error 8:
Reference point not OK.
Error 9:
Rpm detection defective /
Anti-block device is active.
Error 10:
Power limit is active.
Error 11:
Excess travel stop
is active.
Error 15:
Testing photocell not OK.
Error 16:
Testing power sensor
not OK.
Error 26:
Voltage monitoring is
active.
Error 28:
Learned power limit is
active.
Error 35:
Electronics defective.
Error 36:
Static current circuit is
interrupted.
GB
English Page 11
D. Installation
• Connect two door link brackets (B) to the door connector (C).
• Screw this to the centre of the upper edge of the door leaf using 4 screws
(drill ø 5 mm).
• Insert the door link (D) together with the bolt (F) into the carriage (E).
• Fix it with 2 screws.
• Connect the door link and the door link bracket.
Advice!
Remove the door locks or put them out of function!
Garage door operator with sectional door
• Screw the lintel joining plate (A) with boom to the lintel or ceiling, so that
the upper lamella of the door lies approx. 10 mm below the horizontal
downward boom edge - measured from the highest point of the opening
course (see as well point 3).
• Put the motor unit on a trestle or another suitable object until it is fixed later
to the ceiling.
• Join two door link brackets (B) to the door connector (C).
• Screw this to the centre of the upper edge of the door leaf using 4 screws
(drill ø 5 mm).
If necessary, the motor unit can be installed 200 mm off-centre.
• For wooden sectional doors please use wood-screws Ø 5 x 35 mm (drill ø 3 mm).
• Turn two self-tapping screws (D) so far into the door connector, until the
points of the screws are in front of the lamella.
9