Function
Through the pulse zone input and the accepted or altered max. pulse a
pulse zone monitoring is activated. If you fall below the preset training pul-
se by 11 beats, the lettering "LO" appears; if you exceed it by 11 be-
ats, the display will show "HI". The "LO" monitoring is active, if the pre-
set training pulse is reached for the first time when pedalling. If the pe-
dal speed falls to zeros, the "LO" function will become active again
when reaching the preset training pulse. The "HI" monitoring is always
active.
The value which is displayed with the % symbol is the comparison bet-
ween current pulse value and max. pulse value.
If you do not enter any max. pulse value, the % pulse display is not active.
4.4.4 Pulse value monitoring
This input is possible with the +/- keys in the range of 40 - 188.
Function
The "HI" and "LO" display functions as described under 4.4.3. The %
pulse display is not available.
Switch the pulse value monitoring off: "OFF" display, all pulse monitoring
functions are de-activated.
Note
Previously set pulse values in the HRC program are accepted and appe-
ar in the display.
In this mode, the training pulse has no influence on the performance.
(Such a function is offered by the HRC program.)
4.4.5 Completion of preset data
If you press the set key after the last preset value (except in the programs
1-6), all preset values (except preset pulses) will be displayed. The gra-
phics field will read the lettering "Ready" (Fig. 22).
Possibilities of preset training values in the program types:
Count-up
Standard values:
• KM (distance): 0.0 km
• Time (training time): 0:00 min.
• Kilojoule (energy consumption): 0 kJ
• Training pulse: - -
• Max. pulse: - -
• Performance: 25 Watt
Possibilities of preset values in the sequence:
• Age
• Max. pulse
• Pulse zones Fat 65%, Fit 75% and Man. - - %
• Performance
Count-down
Standard values:
• KM (distance): 0 km
• Time (training time): 0:00 min.
• Kilojoule (energy consumption): 0 kJ
• Training pulse: - -
• Max. pulse: - -
• Performance: 25 Watt
Possibilities of preset values in the sequence:
• KM (distance)
• Time (training time)
• Kilojoule
• Age
• Max. pulse
• Pulse zones Fat 65%, Fit 75% and Man. - - %
• Performance
Note:
At least preset the training distance or training time or energy consumpti-
on, otherwise the electronic system will start in count-up mode when taking
up training.
If training time, training distance and energy consumption have been
counted down to zero, the display will change into count-up mode. Now,
the values will again count up from the preset values.
Programs 1-6
Standard values:
• KM (distance): 0.0 km
• Time (training time): depending on program
• Kilojoule (energy consumption): 0 kJ
• Training pulse: - -
• Max. pulse: - -
• Performance: depending on program
Possibilities of preset values in the sequence:
• Age
• Max. pulse
• Pulse zones Fat 65%, Fit 75% and Man. - - %
Performance (not in programs that include a performance range from 25 -
400 Watt)
The adjustment will cause the increase or decrease of the stored program
flow.
Note:
If the training time has been set to zero, the display will change into count-
up mode. Even the time value will count up now.
Pulse controlled program (HRC)
Standard values:
• KM (distance): 0.0 km
• Time (training time): 0:00 min.
• Kilojoule (energy consumption): 0 kJ
• Training pulse: 60 or the training pulse indicated last in the HRC pro-
gram
• Performance: 25 Watt or the starting performance indicated last in the
HRC program
Possibilities of preset values in the sequence:
• KM (distance)
• Time (training time)
• Kilojoule
• Age
• Max. pulse
• Pulse zones Fat 65%, Fit 75% and Man. - - %
• Performance
Note:
For the HRC program KETTLER recommend pulse measuring with the ear-
clip or the cardio pulse set.
The difference between given training pulse and current pulse determines
the performance adjustment. At the beginning of training, the performan-
ce will be increased from the given value until the preset pulse is reached.
If the value is exceeded, the performance will be reduced.
Starting performance can be set from 25 - 100 Watt.
Fig. 17
Pulse zone: Fat consumption with
65%
Fig. 18
Pulse zone: Fitness with 75 %
Fig. 19
Manual pulse selection
Fig. 20
Manual pulse input, e.g. 85%
Y
PULSERPM
KM/H
WATTKM
KILOJOULE
TIME
Fig. 22 Display with preset value
prior to start of training
Fig. 21
Pulse value input, e.g. 150
13

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kettler PX1 - 07989-000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kettler PX1 - 07989-000 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Pools als bijlage per email.

De handleiding is 7,84 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Kettler PX1 - 07989-000

Kettler PX1 - 07989-000 Installatiehandleiding - Nederlands, Deutsch, English, Français, Italiano, Português, Espanõl, Polski, Dansk - 36 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info