In any case, consult your responsible Master Chimney Sweep. He
is able to assess the house's entire ventilation setup and will
suggest the suitable ventilation measures to you.
Unrestricted operation is possible if the vapour extractor hood is
operated exclusively in the circulating-air mode.
Risk of injury!
Components inside the appliance may have sharp edges. Wear
protective gloves.
Risk of electric shock!
Components inside the appliance may have sharp edges. These
may damage the connecting cable. Do not kink or pinch the
connecting cable during installation.
Risk of electric shock!
Penetrating moisture may cause electric shock. Ensure that the
plug connections for the electric cable are located within the
building.
Risk of electric shock!
Penetrating moisture may cause electric shock. Ensure that the
mounting plate is sealed onto the outside wall using suitable
material.
Danger of suffocation!
Packaging material is dangerous to children. Never allow children
to play with packaging material.
General information
Exhaust duct
Note: The device manufacturer does not assume any warranty for
complaints attributable to the pipe section.
The device achieves its optimum performance by means of a
short, straight exhaust air pipe and as large a pipe diameter as
possible.
As a result of long rough exhaust air pipes, many pipe bends or
pipe diameters that are smaller than 150mm, the optimum
extraction performance is not achieved and fan noise is
increased.
The pipes or hoses for laying the exhaust air line must consist of
non-combustible material.
Round pipes
An inner diameter of 150mm, but at least 120mm, is
recommended.
Flat ducts
The inner cross-section must correspond to the diameter of the
round pipes.
dia. 150mm ca. 177cm2
dia. 120mm ca. 113cm2
Flat ducts should not have any sharp deflections.
Use sealing strips for deviating pipe diameters.
Electrical connection
: Risk of electric shock!
Components inside the appliance may have sharp edges. These
may damage the connecting cable. Do not kink or pinch the
connecting cable during installation.
The required connection information is on the appliance's
identification plate.
This appliance complies with the EC interference suppression
regulations.
This appliance may be connected to a correctly installed earthed
socket only.
Fit the earthed socket in close proximity to the appliance.
The earthed socket should be connected via its own circuit.
If the earthed socket is no longer accessible after installing the
appliance, an all-pole isolating switch (e.g. circuit breaker, fuses
and contactors) with at least a 3-mm contact gap must be
included in the installation.
Installation preparation
Caution!
Ensure that there are no electric wires, gas or water pipes in the
area where holes are to be made.
Checking the wall
The wall must be level, vertical and adequately load-bearing.
The depth of the boreholes must be the same length as the
screws. The wall plugs must have a secure grip.
Suitable fasteners must be used for other structures, such as
plasterboard, porous concrete, and poroton bricks.
The max. weight of the appliance is 7kg.
Only specialist personnel must create the required wall
breakthrough. The building support structure must remain in
place.
Risk of damaged caused by returning condensate. Install the
wall breakthrough with a slight outward gradient (1° downward
slope).
Exhaust connection
Connection piece, 200 mm diameter, enclosed
AD 702042: Pipe adapter for connecting pipes from dia.
200mm to dia. 150/125mm. To adapt to a diameter of 150or
125mm, saw off the diameter that is not required.
(Optional accessory, please order separately)
AD 702 052: Telescopic wall outlet, dia. 200 mm, with integrated
back-flow flap
(Optional accessory, please order separately)
AD 854047: Air collector for two flat ducts
(Optional accessory, please order separately)
AD 704047: Air collector for two round pipes, dia. 150mm
(Optional accessory, please order separately)
AD 704 048: Air collector for two round pipes, 150 mm diameter
(Optional accessory, please order separately)
Fitting the appliance on the outside wall
Caution!
Ensure that there are no electric wires, gas or water pipes in the
area where holes are to be made.
1. Create the wall breakthrough with a diameter of at least 210 mm.
2. Insert the telescopic wall outlet AD 702 042(optional accessory,
please order separately) into the wall breakthrough and secure
and seal using construction foam or construction adhesive.
Note: Install the wall outlet with an outward gradient of to allow
for condensate drainage.
3. Drill 8 mm mounting holes and the cable passage with a diameter
of at least 20 mm into the outside wall. (Fig. 1)
4. Press in the wall plugs flush with the wall.
5. Seal the mounting plate appropriately against the outside wall
and tighten it. (Fig. 2)
6. Guide the mains cable and the control cable through the wall.
(Fig. 3)
7. Screw the fan module onto the mounting plate.
8. Secure the exhaust air pipe into the wall outlet. If an aluminium
pipe is used, smooth the connection area beforehand
Note: When combined with gas-fired appliances, use aluminium
pipes. Do not use any plastic pipes. Due to the higher extracted
air temperature, plastic pipes may become deformed.
9. Screw the inner control unit to the wall.
Connecting the appliance to the power supply
1. Fit the plug onto the mains cable. Secure the blue wire in
connection N, the brown wire in connection L and the green/
yellow wire in the central connection. Fit the connector parts.
Tighten two screws for the strain relief. (Fig. 4)
2. Firmly insert the mains cable and control cable from the fan
module into the control unit. (Fig. 5)
3. Firmly insert the network cable from the control unit to the
extractor hood. The plug must snap into place.
Note: The connection sockets X1and X2are identical.
4. Connect the control unit to the mains and check that it works
correctly. If the appliance does not work: Check that the
connection cable is positioned correctly.
Additional switching output
Work must only be carried out on the additional switching output
by a qualified electrician in accordance with the country-specific
requirements and standards.
The appliance has an additional switching output X16(potential-
free contact) that can be used to connect other appliances, such
as a ventilation system that is available at the installation site. The
contact is closed when the fan is switched on, and is opened when
the fan is switched off.
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gaggenau AR401142 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gaggenau AR401142 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Deens, Zweeds als bijlage per email.

De handleiding is 4,37 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info