Ferm 0370 Ferm
DK
PLANER
The numbers in the following text correspond
with the pictures at page 2.
Read through these operating
instructions carefully before using the
appliance. Become familiar with the
functions and method of operation. To
ensure proper operation, always
maintain the appliance according to the
instructions. The operating instructions
and associated documents should
always be kept close to the appliance.
intended use
This doubly insulated electric tool is designed to
be manually operated. It has an appealing shape
and small dimensions, which facilitate easy
transportation. It is safe and reliable when in
operation. It is driven by a single phase electric
motor via a V-belt. It is suitable for planing
wooden beams or boards.
Contents
1. Machine data
2. Safety instructions
3. Assembly and operation
4. Maintenance
1. MACHINE DATA
Technical specifications
Parts list
(Fig. 1)
A Control knob for adjustment of planing depth
B Indication of planing depth
C Cover, right
D Operating Switch
E Release Button
F Handle
G Cover, left
2. SAFETY INSTRUCTIONS
The following pictograms appear throughout
these operating instructions:
Indicates danger of injury, risk to life
and possible damage to the appliance
if these instructions are not followed.
Wear a dust mask
Indicates the presence of electrical
current.
When using power tools, you must observe
the follwing basic safety precautions in order
to ensure protection from electric shocks,
injury and fire. Read and follow all the
instructions before using this power tool.
Look after the notes on safety.
Electrical safety
Always check if your mains voltage
corresponds with the value on the type
plate.
The machine has been double-
insulated in accordance with EN
60745; therefore, an earth wire is not
necessary.
When replacing old cables or plugs
Throw away old cables or plugs immediately as
soon as new ones have replaced these. It is
dangerous to put the plug of a loose cable into
the socket outlet.
When using extension cables
Only use an approved extension cable that is
suitable for the machine’s power. The cores must
have a diameter of at least 1.5 mm2. When the
extension cable is on a reel, unroll the cable in its
entirety.
Switch off the machine immediately in case of
1. Malfunction in the mains plug, power cable or
damaging of cable.
2. Broken switch.
3. Smoke or stench of scorched insulation.
Voltage | 230 V~
Frequency | 50 Hz
Power consumption | 650 W
Number of revolutions, idle | 16000/min
Maximum planing depth | 2 mm
Maximum planing width | 82 mm
Weight | 2,6 kg
LpA (sound pressure) | 85,3 dB(A)
LwA (sound capacity) | 96,3 dB(A)
Vibration value | 2,56 m/s2