696805
10
Verklein
Vergroot
Pagina terug
1/20
Pagina verder
Installation manual
10
6 Placing the decoration material
It is not permitted to use other or to add more material in the
combustion chamber.
Keep the pilot light always free of decoration material!
Place the glass plate on the bottom in the recesses on the
left and right. See g. 6.0a and b.
Spread the glass fragments over the glass panel (one layer)
and cover these with the supplied vermiculite grains.
(The amount of vermiculite affects the intensity of the glow
effect and can be done according to your own discretion).
Place the imitation logs. Make sure that the logs are properly
connected to the tube burners and rest on the bottom of the
re.
If necessary remove glass fragments and/or vermiculite
underneath the burners. (See the supplied log set instruction
card).
Spread the rest of the vermiculite and the chips over the
bottom of the burning chamber. Ensure that the air openings
are not covered.
Start the re as described in the user manual. Check the appearan-
ce of the ames and for burning against the vermiculite grains.
7 Checking the installation
7.1 Checking the ignition of pilot light and
main burner
Light the re as described in the user manual.
Check that the pilot ame is not covered by chips and/or an
imitation log.
Check the ignition of the main burner on full and low setting.
(ignition must be smooth and quiet).
7.2 Checking for gas leaks
Check with a gas leak nder or spray all connections and pipes for
gas leakage.
7.3 Checking the burner pressure and
primary pressure
Check that the burner pressure and primary pressure match with
the information listed in the manual. See Chapter 14.
Measuring the primary pressure:
Close the shut-off valve.
Turn measuring nipple A (see g. 8.0) some few turns open
and connect a measuring hose to the gas regulator.
Take this measurement at highest setting of the re and when
the re is set to pilot light.
Do not connect the unit if the pressure is too high.
Measuring the burner pressure:
Check the burner pressure only with proper primary pressure!
Turn measuring nipple B (see g. 8.0) some few turns open
and connect a measuring hose to the gas regulator.
The pressure must correspond to the value indicated in the
technical specications of this manual. In case of deviation
contact the manufacturer.
> Please note:
Close all pressure measuring nipples and check for gas leakage.
7.4 Checking the ame image
Let the re burn for at least 20 minutes at highest setting and check
the ame for:
Flame distribution
Color of the ames
If one or both points are not acceptable then check:
The log set layout and/or the amount of glass granulate/chips
on the bottom plate.
The pipe connections for leaks (in case of blue ames).
Whether the correct ue restrictor is tted. See g. 9.0.
• The outlet.
o Wall terminal right side up
o Roof terminal on the right position
o If the maximum horizontal ue lengths is not exceeded.
8 Instructions for the client
Recommend that the unit should be checked annually by a
qualied specialist to ensure the safe use and to guarantee a
long service life.
Give advice and instructions on care and cleaning of the
glass. Highlight the danger of burnt-in ngerprints.
Instruct the customer on the operation of the appliance.
Hand over to customer:
o Installation manual
o User manual
o Log set instruction card
9 Annual maintenance
9.1 Checking and cleaning
Check and clean if necessary after verication:
o the pilot light
o the combustion chamber
o the glass
o the logs for breakage
o the outlet
o the wiring/contacts for corrosion
Replace, if necessary:
o chips/vermiculite
o Glass granulate
9.2 Cleaning the glass
Most deposits can be removed with a dry cloth. Clean the glass
with Faber glass polish..
> Please note:
Avoid ngerprints on the glass. These are no longer removable
after they are burnt in!
Now carry out check-up as described in Chapter 7.
10 Conversion to other gas type
Conversion to another type of gas can only be carried out by a
qualied installer / dealer.
To do so, please contact your dealer.
Specify with your order always the type and serial number of the
device.
10

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Faber-Vejen

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Faber Vejen bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Faber Vejen in de taal/talen: Engels als bijlage per email.

De handleiding is 9,7 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Faber Vejen

Faber Vejen Installatiehandleiding - Nederlands - 24 pagina's

Faber Vejen Installatiehandleiding - Deutsch - 28 pagina's

Faber Vejen Installatiehandleiding - Français - 24 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info