8
1 Dear user
Congratulations on purchasing your Faber product, a quality
product that will provide you with the warmth and atmosphere for
many years. Please read the user manual before using the re.
Should a malfunction occur despite the careful nal checks, then
you can always contact your Faber dealer.
In order to claim the guarantee, it is important that you register the
re. For this we have created a special site. You will nd all
information regarding the warranty during registration.
> Please note:
The data of your re is available in the user manual.
1.1 Introduction
Installation and maintenance of the re must be carried out by a
professional expert who has proven knowledge and demonstrable
competence. A professional craftsman takes into account all
technical aspects such as heat delivery, gas connection as well as
ue gas discharge requirements.
Where the installation instructions are not clear, he must follow
national / local regulations.
1.2 Please check
You can register your re at: www.faber-res.eu
Check the re for transport damage and report any damage
immediately to your dealer.
1.3 CE-declaration
Glen Dimplex Benelux certies that this Faber re complies with the
essential requirements of the gas appliances directive.
Product: gas room heater
Model: Vejen
This appliance complies with the Gas Appliance Regulation (EU)
2016/426.
Harmonized standards applied: EN 613 2000/A1 2003.
This declaration is invalid, if without the written permission of Glen
Dimplex Benelux:
- Changes are made to the appliance.
- The re is connected to other exhaust materials than
specied.
2 Safety instructions
> Please note:
It is advisable to always install a screen for the replace if children,
elderly or disabled people are present in the same room as the
replace. If regularly vulnerable persons can be present in the
room without supervision, sufcient protection must always
be placed around the replace.
• The appliance is designed for atmospheric and heating
purposes. This means that all visible surfaces, including the
glass, can become hotter than 100 ° C. An exception to this
is the underside of the replace and the control buttons.
Do not use the remote control and / or app outside the room
where the re is located. So that you are always aware of the
situation around the replace when it is being operated.
The unit must be installed and subsequently serviced every
year and maintained in accordance with these instructions
and the applicable national and local regulations.
Ensure that the data on the type label matches the local gas
type and pressure.
The settings and the construction of the re must not be
changed!
Do not place extra imitation wood or other smoldering
material on the burner or in the combustion chamber.
Do not place any combustible materials within 1m of the
radiation area of the re.
Through the natural air circulation of the re moisture and
uncured volatile components from paint, building materials
and carpeted oors, etc. are attracted. These parts can settle
as soot on cold surfaces. Therefore do not light the re
shortly after installation.
Light the re for the rst time and run for several hours on the
highest setting, so that the paint can cure. Provide adequate
ventilation, so that any fumes can disperse; we recommend
vacating the room during this process.
> Please note:
1. All transport packaging is removed.
2. No children and pets in the room present.
3 Installation requirements
3.1 Minimum distance to combustible materials
around the re
Keep a minimum distance of 9cm to the back wall and 50cm
at the sides.
3.2 Flue pipe and terminal requirements
For the supply of the combustion air and the discharge of the
combustion gases you should always use the Flue materials
specied by Faber.
> Please note: Only when using these materials can Faber
guarantee the safe and proper operation of the appliance.
* This appliance must be installed in a chlorine-free
environment.
* The outside of the concentric ue material can heat up to
+/-150°C. Ensure, when penetrating a ammable wall or
ceiling, construction with proper insulation and protection.
Ensure sufcient clearance is maintained.
* Ensure that the concentric ue pipes are supported every
meter, so that the weight of the pipes is not supported by the
re.
* It is not permitted to start directly on the device with
concentric cut down pipe material.
The air supply could then possibly be closed.
3.3 Terminals
The combined supply and discharge can be done both via wall or
through the roof or through an existing chimney. Verify if the
position of the terminal meets the local regulations regarding
ventilation openings. The ue outlet can end on an external wall or
a roof.
Check whether the outlet desired by you complies with local
requirements concerning good function and ventilation systems.
> Please note:
For a proper functioning the terminal should be at least 0,5m. away
from:
Corners of the building
Roof overhangs and balconies
Eaves (with the exception of the roof ridge, see Chapter 15).
8

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Faber-Vejen

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Faber Vejen bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Faber Vejen in de taal/talen: Engels als bijlage per email.

De handleiding is 9,7 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Faber Vejen

Faber Vejen Installatiehandleiding - Nederlands - 24 pagina's

Faber Vejen Installatiehandleiding - Deutsch - 28 pagina's

Faber Vejen Installatiehandleiding - Français - 24 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info