DIP switch 4
Maximum sensitivity (default setting)
Reduced sensitivity = optional masking of interference sources
Despite careful planning and positioning, interference sources
can still cause undesired switching, such as local hot air streams
from heaters or underfloor heating; ventilators, air-conditioning
units, fans, lights, TVs and HiFis, or computers.
NB: If reducing the sensitivity does not manage to mask the
interference source completely, you can also mask out individual
areas of detectors by means of the enclosed covering clips / lens
mask. Alternatively you will need to re-position the detector.
5.3 Additional manual control by button
5.3.1 “lighting” channel
The detectors have a separate “S” terminal for connecting an external button (button –
operating current – with zero conductor connection). This means that the detector can be
manually overridden at any time so that the lighting-C1” channel can be switched on or off
individually.
Manual switch-on: The lighting will remain switched on for as long as the detector continues
to detect movement. If movement is no longer detected, the lighting will switch off and the
detector will revert to the set operating mode once the set time has elapsed.
Manual switch-off: The lighting will remain switched off for as long as the detector continues
to detect movement. If movement is no longer detected, the detector will revert to the set
operating mode once the set time has elapsed.
The button function can also be set as follows:
DIP switch 3
“Room” button function – manual switch-on and switch-off (default setting)
“Hallway” button function – manual switch-on only
Manual switch-off not possible, safety function for pathway and
hallway lighting
5.5. Control: acoustic sensor (MD-C 360i/8 MIC + PD-C 360i/8 MIC)
The acoustic sensor can only be adjusted manually using the control.
• Turning all the way to the left (-) deactivates the sensor
• Turning all the way to the right (+) maximises sensitivity
The acoustic sensor will only be enabled if the detector is activated first, either by
movement or by switching on manually (button or remote control). This stops noises from
outside the monitored area affecting operation.
Automatic switch-off: if movement or noise is no longer detected, the lighting will be
switched off once the set time has elapsed. The lighting can be immediately re-activated,
e.g. by calling out (making a noise), within 8 seconds. The acoustic sensor should be
adjusted to take into account the surrounding area (noise from nearby HiFis or TVs could
trigger the sensor, for instance). The green LED indicates the acoustic sensor’s response.
6 DISPOSAL / WARRANTY
This device must not be disposed of as unsorted residual waste. Owners are
required by law to correctly dispose of used devices. More information is
available from your local town council.
ESYLUX manufacturer's warranty at www.esylux.com. Technical and design features may
be subject to change. Technical data for products at www.esylux.com/products.
5.4 Sensitivity adjustment
DIP switch 2 Toggle between “fully automatic and semiautomatic operation”
Fully automatic mode – “lighting” switching channel – see 4.1
Semiautomatic mode – only for “lighting” switching channel
Manual switch-on: The detectors have a separate “S” terminal for
connecting an external button (button – operating current – with
zero conductor connection). This means that the detector can
be manually overridden at any time so that the lighting can be
switched on or off individually.
Automatic switch-off: If movement is no longer detected, the
lighting will be switched off once the set time has elapsed.
MD-C 360i/8
MD-C 360i/24
MD-C 360i/32
MD-C 360i/32 Corridor MD-C 360i/8 MIC
PD-C 360i/8
PD-C 360i/24
PD-C 360i/32
PD-C 360i/32 Corridor PD-C 360i/8 MIC
PD-C 360i/8 plus
PD-C 360i/24 plus
PD-C 360i/32 plus PD-C 360i/24 Dry
230 V ~ / 50 - 60 Hz
Power consumption in W 0,3 0,3 0,3 0,3 0,3 0,3
Field of detection 360°
Range (diameter in m)
8
24
32
8
8
24
32
8
8
24
32
24
Settings on device or via remote control Mobil-PDi/MDi
Light value approx. 5 lux - 2000 lux / daytime operation
“Lighting” channel
Switching capacity: 2300 W / 10 A (cos φ = 1),
1150 VA / 5 A (cos φ = 0.5), capacitive load / electronic
ballasts *
Switching capacity: floating / NC, 230 V ~ / 5 A,
24 V / 5 A, capacitive load / electronic ballasts * 2x
In-built acoustic sensor
Time setting: impulse / 1 min. - 30 min.
Switch input – lighting
“HVAC” channel
Switching capacity: floating / NO, 230 V ~ / 2 A,
24 V / 2 A, capacitive load / electronic ballasts *
Time setting: impulse / 5 min. - 120 min.
Slave connection: PD-C 360/8 Slave, PD-C 360/24 Slave,
PD-C 360/32 Slave
Protection type: recessed-mounted IP 20,
IP 20 / IP 54 with surface-mounted box (accessory),
ceiling-mounted IP 20 (accessory)
Protection class II II II II II II
Operating temperature range -25 °C ... +50 °C
Colour: white, similar to RAL 9010
* inrush limiter required
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Esylux MD-C serie bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Esylux MD-C serie in de taal/talen: Engels als bijlage per email.

De handleiding is 0.57 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Esylux MD-C serie

Esylux MD-C serie Gebruiksaanwijzing - Nederlands - 35 pagina's

Esylux MD-C serie Gebruiksaanwijzing - Deutsch - 3 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info