10
4.2 - Electrical connection and working test
1 - The safety measures 3.2, 3.3 and 3.4 of paragraph 3 are to be strictly observed.
2 - Once the electrical connection has been completed, check that worktop illumination, motor and
speeds work properly.
4.3 - Ducting or Recirculation fitting.
1 - Ducting fitting:
a) The hood can be ducted to the outside using a rigid or flexible ducting pipe Ø 100 or 150
mm, the choice of which is left to the installer. When Ø 120 ducting pipe is to be used, it will
be necessary to install the reduction flange A on the hood air outlet (fig. 4).
b) Connect the air outlet to the outside using the rigid or flexible ducting pipe, which must be
fastened using a suitable pipe connectors. The installer must provide suitable material for this
operation.
c) If the hood is provided with charcoal filters, these must be removed (see paragraph 3 3.2-b)
2 - Recirculation fitting:
a) Fix the plug T into the bottom chimney section I, using one of the screws provided in the
accessories (fig. 5). The filtered air will be returned to the room through the grille on the
chimney itself.
b) Install the activated charcoal filters inside the hood canopy (see paragraph 3 3.2 part 2).
4.4 - Fitting the telescopic chimney stack.
1 - Fixing the chimney (fig. 6).
a) Position the tongues on the bottom section I so that they correspond with the fixing tongues
on the hood canopy C, bearing in mind that the slide guide on the two chimney sections must
face towards the wall.
b) Fix the chimney to the hood canopy using the two screws provided in the accessories.
2 - Adjusting the telescopic chimney stack (fig. 7).
Unscrew the two screws at the rear of the chimney, adjust the top section S until it is in the
position required and then lock the two screws to fix in place.
Part 2
a
OPERATION AND MAINTENANCE INSTRUCTIONS
1 - SAFETY WARNINGS
It is most important that all the warnings shown in paragr. 3 of the Installation
instructions are strictly observed. Moreover pay special attention to the following warnings
during the use and maintenance of the cooker hood.
1.1 - The grease filters and the charcoal filter should be cleaned or replaced as
recommended by the manufacturer or more frequently if the hood is used consistently
(over 4 hours per day).
1.2 - When using a gas hob in conjunction with the cooker hood, never leave the burners
uncovered while the hood is in use; when removing the pans either turn the hob off
or keep the flame to a minimum if it is only for a few minutes and under
supervision.