Functions, jumpers and displays
34 | EN
Time
The Tune jumper (off-switch timer) is used to configure the maximum length of time that the
acoustic sounder (sounder tone) is active following an alarm. You can choose between
five seconds and three minutes.
If you do not connect a jumper, a switch-off time of 15 minutes is set.
Jumper open = 15 minutes
Jumper “3 m” = 3 minutes
Jumper “5 s” = 5 seconds
Note:
The sounder flashes until the alarm is acknowledged on the alarm panel.
BAT A/B
Insert the battery connectors (taking care to observe correct polarity) until the connector is
locked in place.
Important
Insert the wires of the battery connector cable into the wire guides provided. Other-
wise, the wires may be crushed.
Operation of the comfort LEDs
In normal operation, the comfort LEDs flash alternately if the sounder is connected to the power
supply to visually display that the system is operational.
When installer mode is activated on the alarm panel, the two comfort LEDs are continuously on for
several minutes. The comfort LEDs are also permanently on during the silent start phase between
connection of the batteries and up to ten seconds after closing the cover.
Note:
Software version display
The software version of the sounder is indicated by the comfort LEDs immediately after the power
supply is connected.
The red comfort LED indicates the major software version.
The left comfort LED indicates the minor software version.
The red comfort LED indicates the design (2 = wireless sounder).
Example: Right LED flashes once
Left LED flashes eight times
Right LED flashes twice