Functions, jumpers and displays
32 | EN
Functions, jumpers and displays
Installer mode
The sounder’s installer mode prevents the sounder and the flashing light from being activated
when the cover is opened.
Installer mode is activated when installer mode is called up on the alarm panel and is deactivated
when installer mode is exited.
When installer mode is activated, the two comfort LEDs are continuously on for several minutes.
Jumpers and battery connector
Note:
Changes to jumpers are only applied if the sounder’s tamper switch is open.
However, if you have closed the tamper switch for testing purposes, a change to the jumpers will
not have any effect.
Figure 3: Jumpers and connectors
Key:
Set Conf
Jumper for activating confirmation in the event of the alarm panel being activated/de-
activated
Jam Det
Jumper for activating jamming monitoring
Tone Jumper for selecting the desired normal alarm tone
Time Jumper for selecting the siren duration
Bat A/Bat B
Battery connectors