Problem
Burners burn with a yellow or orange
flame, in conjunction with the smell of
gas.
Burner does not light, or flame is low
in HIGH position.
Experiencing flare-ups:
ƽCAUTION: Do not line the bottom
tray with aluminum foil.
Burner flame pattern is erratic. Flame
is low when burner is on HIGH. Flames
do not run the whole length of the
burner tube.
Grill seems to lose heat when cooking
in temperatures
50° F or colder. (The liquid propane in
the cylinder turns to vapor too slowly
to supply the burners with gas. This is
due to the air temperature cooling the
LP cylinder which slows the
vaporization process.)
Burners do not light. -or- Burners have
a small flickering flame in the HIGH
position. -or-
Grill temperature only reaches 250˚ to
300˚ in the HIGH position.
Check
Inspect Spider/Insect screens for
possible obstructions. (Blockage
of holes.)
Is LP fuel low or empty?
Is fuel hose bent or kinked?
Does the left burner light with a
match?
Are you preheating grill in the
prescribed manner?
Are the cooking grates and
Flavorizer
®
bars heavily coated with
burned-on grease?
Is the bottom tray "dirty" and not
allowing grease to flow into catch pan?
Are burners clean?
Is there frost/ice on the outside of
the LP cylinder?
The excess flow safety device,
which is part of the grill to cylinder
connection, may have activated.
Cure
Clean Spider/Insect screens and
inspect burners. (See Maintenance
Section.)
Refill LP tank.
Straighten fuel hose.
If you can light the left burner with a
match, then check the Crossover
®
ignition system(pg. 42).
All burners on high until
thermometer reaches 550°F.
Clean thoroughly. (See Cleaning
Section.)
Clean bottom tray.
Clean burners. (See Maintenance
Section.)
Turn off burner control knobs and
the LP cylinder. Replace with a
spare LP cylinder and resume
cooking.
ƽWARNING: The spare or
disconnected LP cylinder must
be stored outdoors in a well
ventilated area out of the reach
of children. The spare or
disconnected LP cylinder must
never be stored under or near
your Vieluxe
®
grill.
Too reset the excess flow safety
device turn all burner control knobs
and the cylinder valve OFF.
Disconnect the regulator from the
cylinder. Turn burner control knobs
to HIGH. Wait at least 1 minute.
Turn burner control knobs OFF.
Reconnect the regulator to the
cylinder. Turn cylinder valve on
slowly. Refer to “Lighting
Instructions”.
HEAT ZONE TROUBLESHOOTING
If problems cannot be corrected by using these methods, please contact Customer
Service toll free at 1 (866) Vieluxe
®
.