LCD+
User Guide GB
LCD+ solar Controller 3 - 17
Bedienungsanleitung D
LCD+ Solarregler 18 - 35
Controller solare LCD+ 44-53
2
LCD+ LCD solar Controller
Installation and Operation Manual
IMPORTANT!
Before starting work the installer should carefully read this
Installation & Operation Manual, and ensure all instructions are
observed and understood.
The Solar controller should be mounted, operated and
maintained by trained personnel only. Individuals in training are
only allowed to install the product under the supervision of a
qualified installer.
Instructions in this Installation & Operation manual must be
observed when working with the controller. Incorrect operation
shall render the warrenty void. WATTS shall not be liable in the
case of improper usage. Any modifications or alterations are
not allowed for safety reasons. The Solar controller
maintenance may only be performed by service centres
approved by WATTS.
The functionality of the controller is dependant upon the model
and ancillary equipment. This installation leaflet is part of the
product and has to be kept and maintained with the controller.
APPLICATION
The Solar controller is developed for a Solar heating system.
The temperature of the tank water is controlled by temperature
difference “dt” between the solar collector and tank.
The controller is normally used in conjunction with a solar
station which includes a circulation pump and mechanical
pressure Safety valve.
The controller has been designed for use in dry environments,
e.g. in residential rooms, office spaces and industrial facilities.
Verify that the installation complies with local regulations
before operation.
SAFETY INSTRUCTIONS
Before starting work disconnect power supply!
All installation and wiring work related to the controller must be
carried out only when de-energized. The appliance should be
connected and commissioned by qualified personnel only.
Make sure to adhere to local electrical safety regulations.
The controllers are neither splash- nor drip-proof. Therefore,
they must be located in a dry environment.
Do not interchange the connections of the sensors and the
230V connections under any circumstances! Interchanging
these connections may result in life endangering electrical
hazards or the destruction of the unit and other connected
sensors and appliances.
TABLE OF CONTENTS
MAIN CHARACTERISTICS ....................................................... 3
TECHNICAL CHARACTERISTICS ............................................ 3
PRESENTATION (Display, keys)............................................... 4
Main menu: 4
1 Quick start menu .................................................... 4
2 Services ................................................................. 5
2.1 Language ............................................................... 5
2.2 Time & Date ........................................................... 5
2.3 System ................................................................... 6
2.3.1 System 1 ................................................................ 6
2.3.2 System 2 ................................................................ 6
2.3.3 System 3 ................................................................ 7
2.3.4 System 4 ................................................................ 7
2.3.5 System 5 ................................................................ 7
2.3.6 System 6 ................................................................ 7
2.3.7 System 7 ................................................................ 7
2.3.8 System 8 ................................................................ 7
2.4 Outputs configuration ............................................. 8
2.4.1 P1 ........................................................................... 8
2.4.2 P2 ........................................................................... 8
2.4.3 Pump P3 ................................................................ 9
2.5 Inputs configuration .............................................. 10
2.5.1 If no flow meter ..................................................... 10
2.5.2 Grundfos sensors ................................................. 11
GDS2 (Grundfos Direct Sensor) .............................................. 11
2.5.3 Impulse Flow meter: ............................................. 11
2.5.4 Temperature Sensor ............................................ 11
2.6 Energy measurment: ............................................ 11
2.6.1 Solar Energy ........................................................ 12
2.6.2 2nd Energy ............................................................ 12
2.7 Protection function ............................................... 13
2.7.1 Max temp collector ............................................... 13
2.7.2 Overheat protection .............................................. 13
2.7.3 Cooling ................................................................. 13
2.7.4 Recooling ............................................................. 13
2.7.5 Freeze protection ................................................. 13
2.8 Degrees................................................................ 13
2.9 Tubes collector ..................................................... 13
2.10 Factory setting ...................................................... 13
3 Settings Menu ...................................................... 13
3.1 Maxtemp tank1 ..................................................... 13
3.2 dTON tank1 .......................................................... 13
3.3 dTOFF tank1 ........................................................ 13
3.4 dTFS: Fullspeed ................................................... 14
3.5 Mintemp collector ................................................. 14
3.6 Maxtemp tank2 ..................................................... 14
3.7 DtON tank2 .......................................................... 14
3.8 dTOFF tank2 ........................................................ 14
3.9 dTON return ......................................................... 14
3.10 dTOFF return ....................................................... 14
3.11 Thermostat Function ............................................ 14
3.11.1 Start...................................................................... 14
3.11.2 Hysteresis ............................................................ 14
3.11.3 Delay .................................................................... 14
3.11.4 Legionella ............................................................. 14
3.11.5 Timer .................................................................... 15
3.12 Cooling Function .................................................. 15
3.12.1 Cooling start ......................................................... 15
3.12.2 Cooling hysteresis ................................................ 15
3.13 Diff control Function ............................................. 15
3.13.1 Max cold tank ....................................................... 15
3.13.2 Min warm tank ...................................................... 15
3.13.3 dTMax .................................................................. 15
3.13.4 dTMin ................................................................... 15
3.14 Antistagnation Function ........................................ 15
3.14.1 Start Level ............................................................ 15
3.14.2 Stop Level ............................................................ 15
4 Operation Menu ................................................... 15
4.1 Automatic and Off operation................................. 15
4.2 Chimney sweep function ...................................... 16
4.3 Manual testing operation: ..................................... 16
5 Operation hours Menu ......................................... 16
5.1 Data logger set with WATTS software and SD
card 16
6 Temperatures Menu ............................................. 17
7 Special Functions ................................................. 17
7.1 Pump exercise function ........................................ 17
7.2 Dimmer function ................................................... 17
7.3 Security function ................................................... 17
8 Others .................................................................. 17
9 Notes .................................................................... 17
3
Menu structure
Service
English “Language”
Time and date
o Time
o Date
o 24/12h clock
o DST
System
o System 1 - 8
o System Parameter (if available)
Outputs Configuration
o P1 “Information of the use”
o P2 “Information of the use”
o P3 “Information of the use”
Inputs Configuration
o Fixed Flowrate value
Flow (l/min)
o Grundfos sensors
GDS1”Sensor choice”
GDS2 ”Sensor choice”
o Impulse flow meter
T6
Liter/Impulse
o Temperature Sensors
T1- T5
Calibration (Pt-1000)
Energy Measurements
o Solar Energy
Adjustments
o 2nd Energy
Adjustments
Protection func.
o Max temp coll.
o Overheat prot.
Overheat temp
o Cooling
Max temp
o Recooling
Min temp
o Freeze prot.
Freeze Temp
Degrees °C/°F
Tube collectors
Factory setting
Quick start menu
o Configuration sequence
Settings
Maxtemp tank1
dT.ON tank1
dT OFF tank1
“Only available with system with 2 tanks”
Maxtemp tank2
dT.ON tank2
dT OFF tank2
“Only available with system 6”
dT.ON return
dT OFF return
dT FS
Mintemp coll.
“Only available if P3 is used as an Extra function”
Extra Function adjustments
Operation
Automatic
Off
Chimney sweep
Manual testing
Operation h
Operation
dT
Power
Energy
SD card
Temperatures
T1
T2
T3
T4
T5
MAIN CHARACTERISTICS
- Large graphic display with backlight
- Easy use interface (4 keys with scroll menu).
- Several languages available
- SD card interface to save the recorded statistics
(Temperatures, Power, Energy, Time operation…) and
parameters.
- 2 energy counters (1 for solar energy and 1 free to specify).
- 1 Bus connection (RJ45) for Extension module (MULTIPLEX)
and communication option.
- Graphic view for Temperature, power, energy…
- 8 working systems with several extra functions possibility
- 5 Inputs for temperature sensors (PT1000 type)
- 1 Logical Input for Impulse flow meter input (for energy
measurement).
- 2 Analogue inputs for Grundfos direct sensors (Flow,
Pressure and temperature sensor)
- 2 electronics outputs for pump (Standard or PWM) with pump
exercise function.
- 1 standard output for Extra function (to control additional
heat, cooling system…)
- Automatic, Off, Manual test mode and chimney sweep
function.
- Sensors Auto checks (Short circuit and breaks)
- Collector protection (Freeze and overheat)
- Permanent memory storage
TECHNICAL CHARACTERISTICS
Operating temperature
0°C 50°C
Electrical Protection
Installation Category
Pollution Degree
IP20
CLASS I
2
Fusible
Power supply
Maximum Power
Consumption
(with all outputs activated)
5AType Fuse 230Vac
(5x20mm)
230Vac +/- 10% 50Hz
4,7A (~ 1080W)
Outputs:
P1 (Main pump with standard
or PWM speed regulation):
P2 (Pump with standard or
PWM speed regulation, valve):
P3 (Extra, Additional heat,
cooling…)
Triac max. 1A 230VAC.
Minimum power switching
>1W
Triac max. 1A 230VAC.
Minimum power switching
>1W
Relay max. 2A 230VAC
* Higher power
consumption: only possible
with external power relay
Inputs:
T1 (Collector1):
T2 (Tank1):
T3 (Extra sensor):
T4 (Extra sensor, Tank2,
Collector2):
T5 (Collector return):
T6 (Flow meter):
GDS1 & GDS2 (Grundfos
sensor):
Flow or pressure.
PT 1000 type
PT 1000 type
PT 1000 type
PT 1000 type
PT 1000 type
Impulse type (low voltage
5V)
Analogue type
(Grundfos VFS, RPS)
Sensors delivered with the
product:
2 Collectors sensor (red)
1 Tank (grey)
1 Extra (grey)
PT1000 (1.5M 180°C)
PT1000 (3M 105°C)
PT1000 (3M 105°C )
Software version
Displayed during
initialisation
Higher Version 11xx
4
PRESENTATION (Display, keys)
1: Simplified drawing of the installation.
- The graphic of the pumps turn when they are
activated.
- The filled triangles on the valve graphic indicate
the circulation
2: Solar loading is in operation.
3: SD card storage is active.
4: Temperature of different sensors, Pumps speed
indications, Power and Energy quantity stored.
A: Keypad description
Navigation key up or plus key (+)
Navigation key down or minus key (-)
Navigation key left (◄)
Navigation key right (►)
Controller information Overview:
An information screen is available to allow you to view quickly
the status of all temperature sensors and outputs connected to
the controller.
From the main display, press (◄) once to display immediately.
The outputs & Inputs screen will be displayed for 1minute,
press (►) at any time to return to the main screen.
Main menu:
First of all press (►) to enter on the navigation menu.
(The title of the active menu is highlighted in black on the top of
the display)
When you enter on the navigation menu you can choose
another submenu by moving the selection cursor with the
keys (+) or (-), then you can enter this submenu with (►).
From all menus you can press (◄) to return to the previous
menu.
*ATTENTION:
As a safety feature, all critical parameters (System and Extra
function) are not programmable 4 hours after power on. If it is
necessary to modify these parameters, you must power-down
and power-up the controller. No settings are lost when
powering-down, or after a power failure.
After 4 hours it is only possible to alter system optimization
settings.
1 Quick start menu
The “Quick start menu” helps you to configure more easily the
main parameters of your solar controller after the initial
installation.
Power-up the controller and wait until the end of the
initialisation sequence. When the main screen is displayed,
press on the key (►) to access to the “service” menu. Then go
to the bottom of the menu and select the line “Quick start
menu” and press the navigation key (►) once to progress to
the quick start configuration.
The controller will guide you through the menu to configure the
main parameters, you will be prompted to adjust the parameter
value by pressing the (+) or (-) input. Press on the (►) key to
validate the display setting and skip to the next parameter.
The controller will return automatically to the main screen when
the configuration process is complete.
1 2
3
T1_ _
_°C
T2_ _
_°C
T3_ _
_°C
T4_ _
_°C
P1_ _ _
%
_ _ _
KW
_ _ _
KWh
T1
T4
T2
T3
A
SD
 Information -
T1 xxx°C T2 xxx°C T3 xxx°C
P1 xxx% P2 xxx% P3 x
 Information -
Services
Settings
Operation
Operation h
Temperatures
 Service -
English
Time and date
System
Outputs Config.
Inputs Config.
Energy Measurements
Protection func.
Degrees °F
Tube collectors No
Factory setting No
Quick Start menu
5
Quick Start menu step by step:
1/ Language choice
- Choose your language with (+) or (-) and press (►) key to
accept.
2/ Time and Date adjustment
- Adjust the hour with (+) or (-) and press (►) key to accept.
- Adjust the minutes and press () key to accept and skip to
the next line.
The controller will skip automatically to the date line, you can
now:
- Adjust the month with (+) or (-) and press (►) key to accept.
- Adjust the day number with (+) or (-) and press (►) key to
accept.
- Adjust the Year with (+) or (-) and press (►) key to accept.
The controller will skip automatically to the clock format line, to
allow you to adjust the time format. Alter with (+) and (-) press
(►) key to accept.
It is possible to select if you require Daylight summer time
advance function with (+) and (-) press (►) key to accept.
3/ System choice
Select the required system with (+) or (-) press (►) key to
accept.
Following system selection, you will be prompted to adjust the
selected system parameters. Proceed to adjust the system
values with (+) or (-) press () key to accept and continue to
the following step in the configuration.
4/ Output configuration
Select the device connected on the output of your controller
(i.e. standard Pump, PWM pump or 3-way valve) with (+) or (-)
press () key to accept and finish the configuration.
N.B.. Depending on the system choice you may be prompted
to configure the P2 output also.
Now your controller is now set-up.
Note:
It is possible to restart the “quick start menu” operation and
follow the steps above to configure again, alternatively it is
possible to directly access a specific parameter throught the
normal menu structure if you have made an error during the
configuration.
2 Services
2.1 Language
- With (+) or (-) select the line “English” and press (►) to
highlight the line.
- Now you can change the language with (+) or (-), you have
the choice between: English, Deutsch, Français, Español,
Italiano, Nederland, Magyarul, and Portugës.
2.2 Time & Date
With (+) or (-) select the line “Time & Date” and press (►)
It is now possible to select the line which requires adjustment
with by pressing (+) or (-), when the correct line is selected
press (►) to highlight the line.
Then use the (+) or (-) to alter the value.
Time,
- Press () once to allow adjustment of the hour.
- Press () for a second time to allow adjustment of
the minutes.
- Depress (◄) twice to return to the line selection.
 Service --- -
English -
Time and date
System
Outputs Config.
Inputs Config.
Energy Measurements
Protection func.
 Time & Date --- -
Time 08:25
Date 02/03/2011
Thursday
24/12H clock 24H
D.S.T. Yes
P1
System
1
T1
T2
T1 _ _ _°C
T2 _ _ _°C
P1 _ _ _ %
 Pump 1 --- -
Type Std Pump
Speed Control Yes
Min rev pump 0%
Max rev pump 100%
T1_ _ _°C
T2_ _ _°C
T3_ _ _°C
T4_ _ _°C
P1_ _ _ %
_ _ _ KW
_ _ _ KWh
T2
T3
SD
T1 T4
 Service -
English
Time and date
System
Outputs Config.
Inputs Config.
Energy Measurements
Protection func.
Degrees °F
Tube collectors No
Factory setting No
Quick Start menu
6
Date,
- Press () once to adjust the Month.
- Press (►) twice to adjustment the Day.
- Press (►) three times to adjustment the the Year.
- Depress (◄) three times to return to the line
selection.
* The day will be automatically displayed.
24H/12H clock,
- Press (►) once to enable the desired choice for
the time format.
D.S.T.
- Daylight Summer Time, activate this function to
enable the automatic hour change between summer
and winter.
Note: If the power supply to the controller is lost the correct
time will be stored in memory for 24H. Longer periods will
require manual readjustment of the clock.
2.3 System
When the line is highlighted, press (►) to enter the
submenu.Choose between the 8 system options, by pressing
(►) key and choose your system with (+) or (-). There is also
the possibility to add different extra functions by using the P3
output (see “output configuration” Chapter 2.4)
2.3.1 System 1
Basic system, with 1 tank, 1 pump, 1 collectors array and 2
sensors.
With this system you can add extra functions with 1 or 2
sensors (Thermostat, Cooling, Antistagnation, Booster or
Diffcontrol function).
The loading of the tank1 is activated if the temperature
difference “dt between the collector (T1) and the tank1 (T2) is
sufficient.
2.3.2 System 2
System with 2 tanks, 1 pump, 1 valve, 1 collectors array and
3 sensors. With this system you can add an extra function
with 1 sensor (Thermostat, Cooling, Antistagnation or
Booster).
The loading of the tanks is activated if the temperature
difference “dt between the collector (T1) and the tanks (T2,
T4) is sufficient.
You will have different adjustments to define the priority of the
tank and also the loading function for the secondary tank.
These following parameters are available for tsytems with
2 tanks.
Priority Tank
No Prio
No priority is done on the tanks. The two tanks are loaded
independently; the only condition is that the “dt” value is
sufficient to initiate tank loading.
1
The primary tank will be the tank1 managed by the sensor T2.
It will be named with a small number “1” in the tank on the
main screen.
2
The primary tank will be the tank2 managed by the sensor T4.
It will be named with a small number “1” in the tank on the
main screen.
If a primary tank is chosen, the loading of this tank will be
made in priority, the secondary tank will be only loaded if:
- The primary tank will reach the “Maxtemp tank(x)” value
adjusted on “setting” menu.
- If the collector temperature is too small to initiate tank
loading of the primary tank. In this case the secondary tank will
be loaded with the cycle function defined by the two following
parameters. This function allows switch back from second tank
to the priority tank.
(1 cycle = “Prio Time break” + “Prio Time charge”)
Note:
All the time if the “dtMax tank(x)” value of the primary tank
becomes sufficient the loading will switch to the primary tank.
Prio Time charge
Load time duration (ON time) for the cycle function.
- To change the duration press (►) to highlight the line and
select your choice with (+) or (-). (Adjustable to 1 to 30min with
default value 15min)
Prio Time break
Break time duration (OFF time) for the cycle function.
- To change the duration press (►) to highlight the line and
select your choice with (+) or (-).(Adjustable to 1 to 30min with
default value 2min)
 System --- -
System 1
P1
System
1
T1
T2
T1 _ _ _°C
T2 _ _ _°C
P1 _ _ _ %
P1
P2
System
2
T1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
T2 T4
 System --- -
System 2
Prio tank 1
Prio time charge 15m
Prio time break 2m
7
2.3.3 System 3
System with 2 tanks, 2 pumps, 1 collectors array and 3
sensors.
With this system you can add an extra function with 1
sensor (Thermostat, Cooling, Antistagnation).
The loading of the tanks is activated if the temperature
difference “dt between the collector (T1) and the tanks (T2,
T4) is sufficient.
You can choose different possibilities for the priority of the tank
loading. See parts “Priority Tank” for more information.
2.3.4 System 4
System with 1 tank, 1 pump, 1 valve, 2 collector arrays with
2 different cardinal direction (East / West) and 3 sensors.
With this system you can add an extra function with 1
sensor (Thermostat, Cooling, Antistagnation).
The loading of the tank1 is activated if the temperature
difference “dt between collector (T1, T4) and the tank1 (T2) is
sufficient. The valve direction of P2 is achieved by the warmer
of the two collector arrays.
2.3.5 System 5
System with 1 tank, 2 pumps, 2 collector arrays with 2
differents aspects (East / West) and 3 sensors. With this
system you can add an extra function with 1 sensor
(Thermostat, Cooling, Antistagnation).
The loading of the tank1 (T2) is activated if the temperature
difference “dt between the collectors and the tank1 is
sufficient.
The tank will be loaded by the warmer collector (T1 or T4).
P1 // P2
Use this function to authorize the run of the two pumps P1 and
P2 in the same time. (The tank will be loaded by both
collectors)
- To activate the function, press (+) or (-) to select the “P1 //
P2“ line and press (►) to active “yes” this function with (+) or (-
).
2.3.6 System 6
System with 1 collector array, 1 solar tank, 1 pump, 1 valve
and 4 sensors.
With this system you can add an extra function with 1
sensor (Thermostat, Cooling, Antistagnation or Booster).
The loading of the tank1 is activated if the temperature
difference “dt between collector (T1) and the tank1 (T2) is
sufficient.
Heating circuit return pre-heating:
If the "dt" between tank1 (T3) and heating return (T4) is
sufficient, the space heating return will be preheated through
tank1. This saves energy at the external heating source *.
2.3.7 System 7
System with 1 collector array, 1 solar tank, 2 pumps, 1
external heat exchanger.
With this system you can add an extra function with 1
sensor (Thermostat, Cooling, Antistagnation and diffcontrol
function).
The loading of the tank1 is activated if the temperature
difference “dt between collector (T1) and the tank1 (T2) is
sufficient.
Delay P2
You can choose a time delay for the start up of the pump
between the heat exchanger and the tank1. Default value is 1
minutes to give the heat exchanger time to heat up.
- With (+) or (-) select the line “delay P2” and press (►) to put
highlight the line.
- It is now possible to choose the delay for P2 start up with (+)
or (-). (Adjustable 0 to 30 minutes with factory value 1 minute)
2.3.8 System 8
System with 1 tank, 2 pumps, 1 collector array, 3 sensors
and 1 plate heat exchanger. With this system you can add
an extra function with 1 sensor (Thermostat, Cooling,
Antistagnation or booster).
P1 P2
System
3
T1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
T2 T4
P2
P1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
System
4
T1 T4
T2
P1 P2
System
5
T1 T4
T2
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
 System --- -
System 5
P1||P2 No
P2
*
P1
System
6
T1
T1 _ _ _°C
T2 _ _ _°C
T3 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
T2
T4
T3
P1
P2
System
7
T1
T1 _ _ _°C
T2 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
T2
 System --- -
System 7
Delay P2 2min
8
Pump-P1 starts if the temperature difference “dt” between the
collector (T1) and tank1 (T2) is sufficient.
The loading of the tank1 with pump P2 is activated if the
temperature difference “dt” between the external plate heat
exchanger (T4) and the tank1 (T2) is sufficient.
The operation of P1 and P2 pumps is totally independent.
2.4 Outputs configuration
- This menu allows configuration of the specific type of output
and the settings of the device connected to all outputs on the
controller. (E.g.High efficiency or standard pump; with or
without speed control, power relay...etc).
There is also the possibility of using the “free” outputs for an
extra function (Thermostat, Cooling, diffcontrol, antistagnation,
booster...)
Note: The outputs “free”, will be marked “not used”
2.4.1 P1
Main pump output, this output is always used to manage the
solar circuit.
There will be the choice between, High efficiency PWM pump,
standard pump or power relay when large pumps are required.
To change the selected pump press (►) to highlight the line
and select your choice with (+) or (-).
PWM Pump
If a PWM pump is connected, there will be the choice between
the 3 main brands, GRUNDFOS, WILO and LAING.
The speed regulation is done by PWM control "ViH = ~11VDC
ViL = <0,5V VDC" with a signal frequency ~ 250Hz”.
Example of compatibility:
- GRUNDFOS SOLAR PM type.
- WILO STRATOS type.
- LAING ECOCIRC E4 PWM1 type.
It is possible to select in percentage form the minimum and
maximum speed of the pump. (Adjustable from 0 to 100%)
The speed of the pump is variable when the value of dt is
between the range “dtFs” and “dtMin”.
dtFS => dT scale of speed variation.
Speed control of the pumps enables the maximisation of the
energy yield from the collectors.
PWM speed regulation explanation:
Standard Pump
If a standard pump is connected, it is possible to control the
speed of the pump; in this case the speed control is done by
pulse packet function.
It is possible to choose in percent form the minimum and
maximum speed of the pump. (Adjustable 30 to 100%)
The speed of the pump is variable when the value of the dt is
between the range “dtFs” and “dtMin”.
This function is an alternative to the High efficiency pump
(PWM), if it is necessary to optimize the efficiency of the solar
installation a PWM high efficiency pump should be utilized.
If the speed control function is not required, selelct “No Sc as
choice.
Pulse packet speed regulation explained
Important Note:
As the speed control is done by pulse packet, noise can occur
in the hydraulic circuit, check the compatibility of the hydraulic
circuit (fitting, pipe…) before selecting this form of speed
control.
Relay / Valve
If it is necessary to connect a large pump for solar installation
with a large collector array (i.e.Pump Power is greater that the
maximum rated output of the controller) , it is possible to drive
an external power relay to control the pump.
Note: no speed control function will be available with this type
of output.
2.4.2 P2
Output P2 is marked “used by system”, it will be possible to
modify its characteristics as described for P1 previously.
If the output is used to manage a direction valve (in System 2
and 4), no choice will be available.To change the type of the
pump press (►) to highlight the line and select your choice
with (+) or (-).
P2
P1
System
8
T1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
T2
T4
 Outputs configuration- -
P1 “Used by system”
P2 “not used”
P3 “not used”
 Pump 1 --- -
Type PWM Pump
Speed Control Grundsos
Min rev pump 0%
Max rev pump 100%
dTOF
F
dTON
Max rev pump
Pump startup
Min rev pump
dTFs
dTFs
Controlled
Speed range
0%
Pump startup
Min rev pump
dTOFF
dTON
Max rev pump
Min rev pump
dTFs
dTFs
Controlled
Speed range
30%
100%
 Pump 2 --- -
P2 “Used in system”
Type Std Pump
Speed Control no
9
If the output is “not used” there is the possibility to use the
output as a booster pump of the main pump P1 with System 1.
This function is useful when utilizing a “drain back system” to
enable the primary pump P1 to initiate the circulation of the
heat transfer fluid.
In this instance pump P2 is normally installed in series with the
main pump P1.
- You could choose the duration for the running time of P2 with
(+) or (-). (Adjustable 1 to 10 minutes)
Booster function explanation:
Exemple:
2.4.3 Pump P3
P3 is a supplementary output which can be used for an
additional extra function and is generally used in combination
with the solar system or totally independent. There will be a
choice between the different functions depending upon the
selected system configuration selected.
2.4.3.1 Thermostat Heating Function
With an additional sensor (T3) this function is used for
secondary heat source pump (P3) control.
Suggestions:
- Pump controls for Fuel or Gas burner…
- Immersion Electrical Heater inside the solar tank.
Important: In this instance an external power relay must be
connected for the switching of the output load!
Example:
All adjustable settings available for this function are accessible
in the Settings menu; see section “Settings” chapter 2 for a
further explanation of the functions.
2.4.3.2 Thermostat Cooling Function
With an additional sensor (T3) this function is used for
cooling of the solar tank with an external heat sink
Suggestions:
Charging a swimming pool.
Example:
All adjustable settings available for this function are accessible
in the Settings menu; see section “Settings” chapter 2 for a
further explanation of the functions.
2.4.3.3 Diffcontrol Function
With additional sensors (Tcold=T3, Twarm=T4) this function
is used for secondary heat source pump control or charging
a tank.
The loading of the Tcold=T3 is activated if the temperature
difference “dt” between the Twarm=T4 and the Tcold=T3 is
sufficient.
Example 1:
 Pump 2 --- -
P2 Booster
Boost Duration 2min
Tank1
T2 C)
dTMin
dTMax
P1
Collector
T1 C)
Maxtemp
Tank1
dTMax
dT = T1
T2
100%
0%
dTMax
Boost time
P2
T1
P1
T2
Extra Function to control a
second pump in serie with P1
to help the liquid circulation
startupthe pump coupled with
an external burner.
P2
Heat Source
T1
P3
P1
T3
T2
Extra Function to control
the pump coupled with
an external burner.
Heat
sink
T1
P
3
P
1
T
3
T2
Extra Function used to control the pump to
warm up another tank or basin
P3
P1
T2
Extra Function used to control
the pump (P3) to warm up
"Tcold=T3", if the temperature
difference (dt) to "Twarm=T4"
is sufficient.
T1
TC = T3
TW = T4
10
Example 2:
All adjustable settings available for this function are accessible
in the Settings menu; see section “Settings” chapter 2 for a
further explanation of the functions.
2.4.3.4 Booster Function
See the previous part P2 for more explanation of this function.
Exemple:
2.4.3.5 Antistagnation Function
The antistagnation function is used in combination with the
Watts
anti-stagnation unit. At times of excessive solar radiation the
solar fluid is protected from stagnation, where otherwise the
heat transfer fluid would vaporize.
If the solar circuit (T1, T4 (when two collector fields)) is heated
to 110°C (default value, can be changed), the relay output P3
and solar circuit P1 are switched ON. P3 is connected with the
3-way valve and fan of the Watts antistagnation unit.
After the solar circuit is cooled down to 90°C (default value,
can be changed), the outputs P3 and P1 are switched off.
Example 1:
Example 2:
All settings adjustment available for this function will be
accessible in the Settings menu, see parts “Settings” chapter 2
for more explanation of the function and possibilities.
2.5 Inputs configuration
- It is possible to configure and monitor all inputs available on
the controller. (Digital or analog inputs)
2.5.1 If no flow meter
Estimated flow input
If no impulse flow meter is installed (factory setting) the flow
must be entered, which can be seen on the flow-meter in the
solarstation.
The flow reading from the glass-scale at the flow-meter can be
entered by marking the value line with (>) and adjusting the
flow-setting with (+) or (-). (Adjustable 1 to 100 L/min with
factory value 10 L/min)
Important Note:
The flow must be read when the pump is running at 100%
speed.
Other heating system
with tank. (Fuel, pellets,
wood ….)
P
3
P
1
TC =
T3
T2
Extra Function used to control the
pump (P3) to warm up "Tcold=T3", if
the temperature difference (dt) to
"Twarm=T4" is sufficient.
T1
TW =
T4
T1
P1
T2
Extra Function to control a
second pump in serie with P1
to help the liquid circulation
startupthe pump coupled with
an external burner.
P3
P3
P1
T2
Extra Function used to cool down the solar circuit
with the TISUN antistagnation units.
T1
P3
P1
T2
Extra Function used to discharge the collector in
another free heat storage or under ground
discharge loop...
T1
 Inputs configuration -
If no flow sensor
Flow (L/min) 10
Grundfos sensors
GDS1
GDS2
Impuls flow meter
T6
Temperature sensor
T1 xxx°C
T2 xxx°C
T3 not used
T4 not used
T5 not used
* In this case the output P3 will need the
power relay “LR 20 3S”installed.
11
2.5.2 Grundfos sensors
- Your controller had 2 specials inputs for analogics sensors
GRUNDFOS (Type VFS Flow sensor or RPS pressure
sensor).
The Flow sensor is used for energy measuring and
supervision, the pressure sensor is used only to supervise the
pressure on the primary circuit.
GDS1 (Grundfos Direct Sensor)
Once the line selected press (►) to enter in the submenu
GDS1.
You will have the choice between Flow or Pressure sensor with
different scales.
To choose the type of the sensor connected press (►) to
highlight the line and select your choice with (+) or (-).
- NC Not used
- RPS 0 4 bar Pressure sensor
- RPS 0 6 bar Pressure sensor
- RPS 0 10 bar Pressure sensor
- VFS 1 12l/min Flow sensor
- VFS 2 40l/min Flow sensor
- VFS 5 100l/min Flow sensor
- VFS 10 200l/min Flow sensor
- VFS 20 400l/min Flow sensor
Sensor type: see type plate on the mounted sensor
- Following your sensor choice you can view the
instantaneous values of the temperature, flow or pressure
measured by the sensor.
With Flow sensensor “VFS”,
With Flow sensensor “RPS”,
GDS2 (Grundfos Direct Sensor)
This input has the same function and possibilities of the GDS1
input,
2.5.3 Impulse Flow meter:
If impulse flow meter is installed (on T6 / PF) select “Yes”, then
you must enter with (+) or (-) the flow meter characteristics in
liter / Impulse.
(Adjustable 1 to 25 L/imp with factory value 10 L/imp)
When you use an impulse flow meter for energy measuring,
you must
Connect a temperature sensor (usually T5) mounted on the
collector return piping, to get the correct calculated energy
values.
Important Note:
You must not connect an impulse flow meter to T6, if a digital
pressure or flow sensor is connected to GDS2!
2.5.4 Temperature Sensor
This submenu allows viewing of the current state of all
temperature sensors connected on the controller; you can
immediately see the actual value measured by the sensor, if it
is in use or not & if the sensor is defective.
By pressing on the on the (►) key, you will acced the
calibration of the sensor.
Careful: Check the real value of the sensors with calibrated
thermometer before adjusting. (Calibration range -3 to +3°C
with factory value 0°C)
2.6 Energy measurment:
The controller has two energy measurement blocks. It is
possible to configure for both blocks the sensors which will be
used for energy calculation.
Energy metering calculation logic:
To calculate the energy the controller needs several elements,
two temperature measurement points “Warm” and “Cold”, the
flow value and the heat transfer fluid properties.
 GDS1---- --- -
GDS1 NC
 GDS1---- --- -
GDS1 VFS 1-12 l/min
Flow x.x l/min
Temp GDS1 xxx°C
 GDS1---- --- -
GDS1 RPS 0 - 4 bar
Pressure x.x bar
Temp GDS1 xxx°C
 T6 --- -
Impulse flow meter no
 T6 --- -
Impulse flow meter Yes
Liter/impulse 10
 Inputs Configuration---- -
Temperature sensors
T1 xxx°C
T2 xxx°C
T3 xxx°C
T4 not used
T5 not used
 T1 --- -
Pt1000
Calibration 0°C
12
2.6.1 Solar Energy
This first block is reserved to calculate the solar energy; it is
possible to select the sensors used for the calculation.
To change a selected sensor, press (►) to highlight the line
and select the choice with (+) or (-) according the
installation.
Flow sensor
- Auto
The controller will use the theorical flow (liter/min) entered in
the “Inputs configuration” if no flow meter is available.
- T6
The controller will use the impulse meter connected on the
input “T6”.
- GDS1
The controller will use the Grundfos vortex sensor “VFS type” if
connected to the GSDS1 input.
Hot sensor
- Auto
The controller will automatically choose the corresponding hot
sensor according to the system selected (T1 or T4 collector
sensors).
- T1” or “T4
The controller will use the PT1000 sensor T1 or T4 according
to the user selected sensor.
- GDS1
The controller will use the temperature sensing element of the
Grundfos vortex sensor “VFS type”.
Cold sensor
- Auto
The controller will automatically choose the corresponding tank
sensor according to the system selected (T2 or T4 tank
sensors).
- T5
The controller will use the PT1000 sensor T5.
- GDS1
The controller will use the temperature sensing element of the
Grundfos vortex sensor “VFS type”.
Note: Do not choose the same sensor for “Hot” and
“Cold”, The energy calculation will be incorrect.
Fluid
- Water
The controller will use the heat transfer coefficient of water for
the calculation.
- Glycol
The controller will use the Water-Glycol coefficient according to
the percent of glycol selected for the calculation.
Mixing parameter: adjustable from 10% to 50% of Glycol mixed
in the fluid.
Flow (Volume)
- View of the cumulated volume in m3.
It is possible to reset the stored value by holding down on the
(►) & (-) keys for 5 sec.
Energy
- View of the cumulated energy in kWH.
It is possible to reset the stored value by holding down on the
(►) & (-) keys for 5 sec.
Power
- View of the instantaneous power in W.
2.6.2 2nd Energy
The second energy block can be used to calculate or
supervise another circuit, this circuit can be totaly
independant of the solar circuit, (energy supplied by the
additional heat boiler, energy used for D.H.W. etc.).
If it is necessary to use this block, select “Yes” on the “2nd
Energy” line.
The functionality is identical to the above explained 1st
block.
Flow sensor
- Auto
The controller will use the theorical flow (liter/min) entered in
the “Inputs configuration” if no flow meter is available.
- T6
The controller will use the impulse meter connected on the
input “T6”.
- GDS2
The controller will use the Grundfos vortex sensor “VFS type” if
connected to the GDS2 input.
Hot sensor
- T1” to“T5
The controller will use the PT1000 sensor T1 toT5 according to
the user selected sensor.
- GDS2
The controller will use the temperature sensing element of the
Grundfos vortex sensor “VFS type”.
Cold sensor
- “T1” to“T5
The controller will use the PT1000 sensor T5 according to the
user selected sensor.
- GDS2
The controller will use the temperature sensing element of the
Grundfos vortex sensor “VFS type”.
Note: Do not choose the same sensor for “Hot” and
“Cold”, The energy calculation will be incorrect.
Fluid
- Water
The controller will use the heat transfer coefficient of water for
the calculation.
- Glycol
The controller will use the Water-Glycol coefficient according to
the percent of glycol selected for the calculation.
Mixing parameter: adjustable from 10% to 50% of Glycol mixed
in the fluid.
Warm point
P1
Function use for solar
calculation of energy
return.
Cold point Flow meter
 Energy measurement -
Flow sensor Auto
Hot sensor Auto
Cold sensor Auto
Fluid Glycol
Mixed 40%
Flow (Volume) xxxxm3
Energy 0kWh
Power 0.0kW
 2nd Energy -
2nd Energy Yes
Flow sensor Auto
Hot sensor Auto
Cold sensor Auto
Fluid Glycol
Mixed 40%
Flow (Volume) xxxxm3
Energy 0kWh
Power 0.0kW
13
Flow (Volume)
- View of the cumulated volume in m3.
It is possible to reset the stored value by holding down on the
(►) & (-) keys for 5 sec.
Energy
- View of the cumulated energy in kWH.
It is possible to reset the stored value by holding down on the
(►) & (-) keys for 5 sec.
Power
- View of the instantaneous power in W.
2.7 Protection function
With this menu it is possible to select and adjust all the
protective functions and parameters of your installation.
2.7.1 Max temp collector
- Setting the start level of the overheat protection for the
collector array.
(Adjustable 110 to 150°C with factory value 120°C)
2.7.2 Overheat protection
This function will stop all collector circulation (P1 and P2) when
the collector temperature increases above “Maxtemp” plus an
offset value (+10°C default value, can be changed). This
function is used to protect the elements of the installation
(Pipe, fitting, ring rubber...)
- To activate the function, press (+) or (-) to select the
Overheat prot.“ line and press (►) to active “yes” this
function with (+) or (-).
- It is now possible to adjust the offset level
(Adjustable +10°C to +30°C with factory value +10°C)
IMPORTANT: For safety reasons this function should
always be “Yes
2.7.3 Cooling
- When the “cooling” function is active “Yes”, it is also possible
to activate the “Recooling” function.
This option is used to protect the collector heat transfer fluid
and system as follows; it activates the solar pump P1 or P2 if
temperature of the collector arrays T1 or T4 exceeds the “Max
temp coll.” value even if the set maximum temperature in the
tank is exceeded.
The circulation stops when:
- Temperature in the collector has dropped 10°C.
- Temperature in the tank reaches the cooling “Max Temp
level (MaxTemp Tankx + xx°C) adjustable 5°C to +40°C with
default value of +10°C.
- If the water temperature in the tank reaches 95°C.
2.7.4 Recooling
When the water temperature inside the tank is above the
setting level “Maxtemp tank X” and the collector temperature is
10°C under the pump is activated to cool the tank through the
collector array (during the night).
The pump will be turned off when:
- The water temperature inside the tank has dropped to the
setting level recooling “MinTemp”“(MinTemp Tankx - xx°C)
adjustable -5°C to -40°C with default value -10°C.
- When the difference between the tank and collector array
temperature is below 2°C.
2.7.5 Freeze protection
This option will keep the solar panel temperature T1 or T4
above the Freeze setting level (see below) by activating the
pump P1 or P2.
This option can be used to reduce snow accumulation on the
panel and increase the efficiency during the day or to avoid
damage by the freezing and expansion of the heat transfer
fluid.
Careful: it is preferable not to use this function in very cold
regions in order not to use too much the energy stored in the
tank
- To activate the freeze and snow protection, press (+) or (-) to
select the “Freeze prot“ line and press (►) to active “yes” this
function with (+) or (-).
- It is now possible to adjust the Freeze setting level
(Adjustable -20°C to + 7°C with factory value 3°C)
2.8 Degrees
- On this menu you can choose the displayed units.
°F: °F, 12H am/pm, Liter, KW and KWh
°C: ° C, 24H, Liter, KW and KWh
2.9 Tubes collector
Select the lines “Tubes collector” and press (►) to highlight
the line.
- Now select with (+) or (-) yes” if your installation use vacuum
tubes collector. (This choice can be use with flat collector when
the sensor is mounted on the external parts of the collector).
- This function could be used if the collector sensor is not
directly mounted on the collector.
This function works in the following way.
Each 30 minutes the pump will be activated 30 seconds to
measure the correct value on the collector to avoid short
charge cycle.
2.10 Factory setting
Important: For reasons of error protection the selected system
and time settings will not be reset!
- If you want to reload all parameters with factory value select
press (►) to highlight the line. Then select “yes” with (+) key.
- Now press (◄) repeatedly to return to the main menu.
3 Settings Menu
On this menu you have all basic adjustable settings of your
installation.
3.1 Maxtemp tank1
- Maximum value of desired water temperature on the tank1
during normal operation. (Adjustable 15 to 95°C with factory
value 65°C)
3.2 dTON tank1
- Difference between collector temperature T1 and Tank1
temperature T2 to start the main pump1. (Adjustable 4 to 40°C
with factory value 15°C)
3.3 dTOFF tank1
- Difference between collector temperature T1 and Tank1
temperature T2 to stop the main pump1. (Adjustable 2°C bis
35°C (dTMin <=2°C dTMax Tank 1 with factory value 7°C)
 Protection Function -
Max temp coll. 120°C
Overheat prot. Yes
Overheat temp. +10°C
Cooling Yes
Max temp (xx°C) +40°C
Recooling Yes
Min temp (xx°C) -40°C
Freeze prot. Yes
Freeze prot. Temp. -20°C
14
3.4 dTFS: Fullspeed
- Difference between collector temperature T1 and Tank1
temperature T2 to have the full speed (100%) on the pump.
(Adjustable between minimum "dTMax tank1" and maximum
50°C (default value 35°C))
3.5 Mintemp collector
- This setting level is used to define a minimum temperature on
the collector to authorize the solar loading. (Adjustable
between 0°C and 99°C.(default value 25°C))
The following settings are only available with two tanks (2 and
3).
3.6 Maxtemp tank2
- Maximum value of desired water temperature on the tank2.
(Adjustable 15 to 95°C with factory value 65°C)
3.7 DtON tank2
- Difference between collector temperature T1 and Tank2
temperature T4 to start the main pump1 with system2 or
pump2 with system3.
(Adjustable 3 to 40°C with factory value 15°C)
3.8 dTOFF tank2
- Difference between collector temperature T1 and Tank2
temperature T4 to stop the main pump1 with system2 or
pump2 with system3. (Adjustable 2°C bis 35°C (dTMin <=2°C
dTMax Tank 2) with factory value 7°C)
Note:
With a system with two tanks the priority tank can be chosen in
the “Service menu in submenu “System”, and also choose
the time of the loading cycle for the secondary tank in
submenus “Prio tank load” and “Prio tank break”.
The following settings are only available with system 6.
3.9 dTON return
- Difference between Tank1 temperature T2 and external
space heating return T4 to start the preheating of this external
space heating return throuhgh tank1. (Adjustable between 3 to
40°C (default value 15°C))
3.10 dTOFF return
Available only with the system 6
- Difference between Tank1 temperature T2 and external
space heating return T4 to stop the preheating of the external
circuit. (Adjustable 2 to (dTMax return -2°C) with factory value
7°C)
EXTRA FUNCTIONS SETTINGS ADJUSTMENT
The Extra adjustments will be only available if one Extra
function is chosen on an output in the “output configuration”
menu.
3.11 Thermostat Function
Available only if extra function “thermostat” is selected on the
output P3
3.11.1 Start
- setting level to start the additional heat (P3) when the
water temperature on the top of tank (T3) decreases under
this setting level.
(Adjustable 20 to 90°C with factory value 55°C)
3.11.2 Hysteresis
- Value of the hysteresis to stop the additional heat (P3)
when the water temperature on the top of tank (T3) is more
than the start temperature plus the hysteresis value.
(Adjustable 2 to 30°C with factory value 10°C)
The following Timer parameters are available for the
following extra functions, “Thermostat”, “Cooling” &
“Diffcontrol”.
3.11.3 Delay
- Time delay to start the output (P3).
If adjusted on minus value “-xxxs”, the relay P3 will start “xxx
seconds” before the startup demand.
If adjusted on plus value “+xxxs”, the relay P3 will stop “xxx
seconds” after the stop demand.
(Adjustable -900s to +900s with default value “0”)
3.11.4 Legionella
- The Number of days to activate the legionellosis function.
This function is generally used when the tank is filled with
D.H.W., it heats with the extra output (P3) the tank up to
65°C (T3) if the water inside the tank did not reach this level
during the previous number of days selected. (Adjustable 1
to 7 days with factory value 1).
Water temperature on top of tank1 T3 (°C)
T3 start
T3 start +
hysteresis
Extra P3
Tank1
T2 F)
dtMin
dt Fs
P
1
Collector
T1 F)
Maxtemp
Tank1
dt Fs
dT = T1
T2
100
%
0%
dtMax
Control
dtMax
85%
OFF
100%
Control
100%
100%
OFF
15
3.11.5 Timer
- The timer block is used to cretate a daily program to
initialise the operation time of the extra output (P3), this
function is generally use for energy saving in the case of an
additional heat source being used to warm the tank (e.g.:
additional heat is present only at the end of the day if the
sun loading was insufficient during the day.)
To use the Timer function select the line “Timer” and choose
“Yes”, then there is the possibility of adjusting the “start” and
“stop” times for three blocks.
3.12 Cooling Function
Available only if extra function “coolingis selected on the
output P3
3.12.1 Cooling start
- setting level to start cooling the tank1 (by activating P3
output) to another heat storage for example when the water
temperature in the top of tank1 (T3) is above this setting
level. (Adjustable 20 to 90°C with factory value 75°C)
3.12.2 Cooling hysteresis
- Value of the hysteresis to stop cooling the tank1 when the
water temperature on the top of tank (T3) is under Cooling
start temperature minus hysteresis value. (Adjustable 1 to
30°C with factory value 10°C)
3.13 Diff control Function
Available only if extra function “diff controlis selected on the
output P3.
3.13.1 Max cold tank
- Maximum level on tank1 to stop the exchange function (T3
= TC).
(Adjustable 15 to 95°C with factory value 65°C)
3.13.2 Min warm tank
- Minimum level on external tank to start the exchange
function (T4 = TW). (Adjustable 0 to 95°C with factory value
15°C)
3.13.3 dTMax
- Value of the difference between cold and warm storage to
start the exchange function. (Adjustable 3 to 40°C with
factory value 15°C)
3.13.4 dTMin
- Value of the difference between cold and warm storage to
stop the exchange function. (Adjustable 2 to 30°C with
factory value 7°C)
3.14 Antistagnation Function
Available only if extra function “Antistagnationis selected on
the output P3.
3.14.1 Start Level
- Setting level on collector (T1) to start the function, the
pump P1 will be turned on to discharge the warm
temperature of the collector through the relay P3.
(Adjustable 0 to 200°C with factory value 110°C)
3.14.2 Stop Level
- Setting level on collector (T1) to stop the antistagnation
function, the pumps P1 and P3 will be turned off. (Adjustable
0 to 150°C with factory value 90°C)
4 Operation Menu
4.1 Automatic and Off operation
- To put your system in Automatic operation, press (+) or (-) to
select the “Automatic“ line and press (►) to active this
working mode.
- To put your system in Off mode repeat the same sequence
as above.
Note: The controller status is displayed by a small graphic, on
the main screen stating “OFF”
 Settings -
Delay +900s
Timer On
Time 1 Start 24H00
Time 1 Stop 24H00
Time 2 Start 24H00
Time 2 Stop 24H00
Time 3 Start 24H00
Time 3 Stop 24H00
Water temperature on top of tank1 T3
C)
Cooling stop
(start hysteresis)
Cooling
start
P3
Warm storage TW
Cold storage TC
MinWarm
tank
MaxCold
Tank
Extra
P3
dTMin
dTMax
Collector
(T1°C)
Stop level
Start level
P1
Tank (T2°C)
P3
Standard
loading cycle
Antistagnation
cycle
 Operation--------------- -- -----
Automatic (Active)
OFF
Chimney sweep
Manual testing
16
4.2 Chimney sweep function
WARNING USE AT OWN RISK:
The space heating is set up to maximum temperature to
prevent the burner from overheating. Some heating pipes
can be damaged at temperatures over 40°C!
The “chimney sweep” function is used for:
exhaust fume measurements at the heating system
to put maximum heating load on the system
(burn possible deposits in the burner, when run for
extended periods at partial load)
Attention safety rules when using the “chimney sweep
function:
1. Chimney sweep” function is activated for the time it is
needed.
During the Chimney sweep function the outputs:
P3, (with MULTIPLEX P4, P5, P7, P9, P10) will be turned
ON
P1, P2, (With MULTIPLEX P6, P8) will be turned OFF
WARNING: don’t overheat your system!
2. When the “Chimney sweep” is finished, Switch Off the
LCD+ controller for a few seconds. Off (active)
3. Before restarting the LCD+ controller check all elements
(pipes…) of the installation to be ensure that no damages
has occured,
Automatic (active)
4.3 Manual testing operation:
- In this mode it is possible to check the operation of Pump1,
Pump2/Valve and extra outputs. It is also possible to check the
values of all sensors inputs.
N.B. the sensor input not used are noted with the maximum
value.
- To activate the output select the desired line with (+) or (-)
and press (►) to highlight this line. Now with (+) or (-)the
different outputs can be tested.
- The pump activation starts with the minimum value xx%
adjusted on the “Setting” menu (see Pump speed) and can be
increased from 5% up to 100% in steps with (+) key.
Note: When you exit this menu all outputs are turned off.
- Press (◄) repeatedly to return to the main menu.
5 Operation hours Menu
In this menu it is possible to observe the cumulative totals for
operating hours, dT, power and energy input registered by the
controller.
The controller has the ability to record and store all data and
parameters of the installation on an SD card. This enables the
analysis of the efficiency of the solar installation and also
allows the pre-configuration of the installation parameters on
your computer. (This functions require a special Watts Data
Logger Kit with software. Watts order number P04189)
After the SD card is inserted, it must be activated:
Select the SD card line with (+) or (-) and press (►) to highlight
this line. Now with (+) or (-) you can activate or deactivate the
SD card.
SD card Deactivate => the SD card is ready to work
SD card Activate => the SD card is off or deactivated
Attention:
- The recording of the data on the SD card is only possible if
the SD card is inserted and activated. (All data already
registered by the solar controller before will not be recorded
on the computer)
- A small SD card logo on the main screen is visible if the SD
card is inserted and activated.
Important: Do not unplug the SD card before deactivate it.
5.1 Data logger set with WATTS software and SD
card
The controller has the ability to record and store all data and
parameters of the installation on an SD card. This enables the
analysis of the efficiency of the solar installation and also
allows the pre-configuration of the installation parameters on
your computer. (This functions require a special Watts Data
Logger Kit with software. Watts order number P04189)
a) Systems and parameters for the installation
(Schemes, extra functions, speed control, priority tank, flow
sensor …)
- Set the parameters for the system on the computer and
transfer the data to the controller
- Analyze the recorded parameters from the SD card on
the computer
This requires hardware and software: SD card set
- Record the current operation data from the solar system
on the SD card
This requires hardware and software: SD card set; SD card
max. 2GB, no SDHC
b) Operation data; system control and measuring of
energy
(The data of the system can be recorded, as energy,
operation hours, temperatures of the sensors, pump speed and
priority time break, flow …)
- Record permanently the operation data on the SD card
Requires Hard and Software: SD card set
- Analyze of the operation data; system control and
measuring of energy on a PC
Requires Hard and Software: SD card set
Attention::
For the following functions the special Watts Data Logger
Kit no. P04189 is required
- Set the parameters for the system on your computer and
transfer the data to the controller
- Analyze the recorded parameters from the SD card on the
computer
- Analyze of the operation data; system control and
measuring of energy on the PC
For the following functions there is no special Watts Data
Logger Kit required
(For this function only an empty SD card is required. Not
included in the controller)
- Recording permanently the Operation data on the SD card
- Recording the current operation data from the controller on
the SD card.
 Manual testing------------- --
P1 0%
P2 0%
P3 0
T1 _ _ °C T2 _ _°C T3 _ _ °C
T4_ _°C T5 _ _ °C
GT _ °C F _ _ L/min P _ _ Bar
 Operation h------------ -- --- --
Operation _ _ h
dT _ _°C
Power _ _kW
Energy _ _kWh
SD card Deactivated
17
6 Temperatures Menu
- On this menu it is possible to see the instantaneous
values of all sensors connected.
- With (+) or (-) it is possible select a sensor and see its
time graph by pressing the (►).
- Move the time cursor with (+) or (-) to view the complete
scale. When the end of the first window is reached, the
graph will change to show another 100 points.
7 Special Functions
7.1 Pump exercise function
To avoid the jamming of pumps, if they were not activated
during the last 48 hours, they will be activated during 15
seconds.
7.2 Dimmer function
For better energy efficiency the controller backlight is switched
of, when no key is pressed for 15 minutes.
7.3 Security function
To prevent mistakes after installation, all critical parameters
(system and Extra function) are not accessible any more after
4 hours power on. If it is necessary to modify these
parameters, the controller must be powered-down and
powered-up. No settings are lost when unplugging, or after a
power failure.
After 4 hours you can still change all the other parameters to
optimize your system.
8 Others
Corresponding value for sensor PT1000:
(To be check with an Ohmmeter, only when the sensor is
disconnected)
-10°C / -14°F 960 ohms
0°C / 32°F 1000 ohms
10°C / 50°F 1039 ohms
20°C / 68°F 1077 ohms
30°C / 86°F 1116 ohms
40°C / 104°F 1155 ohms
50°C / 122°F 1194 ohms
60°C / 140°F 1232 ohms
70°C / 158°F 1271 ohms
80°C / 176°F 1309 ohms
90°C / 194°F 1347 ohms
100°C / 212°F 1385 ohms
120°C / 248°F 1461 ohms
140°C / 284°F 1535 ohms
Attention:
Extension module MULTIPLEX
If a more complex system or heating circuit is required the
installer can add the multiplex controller to enable these
functions.
9 Notes
 Temperatures --- --
T1 xxx°C
T2 xxx°C
T3 xxx°C
T4 xxx°C
T5 xxx°C
Collector1 xxx°C
- +
82
50
18
0 :00
18
LCD LCD+ Solarregler
Installations- und Betriebshandbuch
ACHTUNG!
Die installierende Person sollte vor Inbetriebnahme des Geräts
diese Installations- und Bedienungsanleitung sorgfältig
durchlesen und sich mit den darin enthaltenen Anweisungen
vertraut machen.
Der Solarregler darf nur von speziell ausgebildetem Personal
montiert, bedient und gewartet werden. Personen, die sich
noch in der Ausbildung befinden, dürfen das Gerät nur unter
Aufsicht eines erfahrenen Technikers bedienen.
Bei Arbeiten mit dem Regler sind alle Anweisungen in diesem
Installations- und Wartungshandbuch einzuhalten. Der
Hersteller haftet nicht für fehlerhafte Installationen. Watts haftet
nicht im Falle einer unsachgemäßen Handhabung.
Änderungen und Erweiterungen jeglicher Art sind aus
Sicherheitsgründen untersagt. Wartungsarbeiten am
Solarregler dürfen nur von Kundendienst-Technikern mit
Hersteller-Autorisierung durchgeführt werden.
Der Funktionsumfang des Reglers hängt vom Modell und der
Anlage ab. Dieses Installationshandbuch gehört zum Produkt
und ist Teil des Lieferumfangs.
ANWENDUNGSBEREICH
Der Solarregler wurde für Solar-Heizungen entwickelt. Die
Temperatur des Wassers im Speicher wird durch den
Temperaturunterschied dt zwischen Kollektor und Tank
geregelt.
Normalerweise wird der Regler zusammen mit einer
Solarstation inkl. Umlaufpumpe und mechanischem
Sicherheitsventil verwendet.
Die Regler sind für den Einsatz in Trockenbereichen
ausgelegt, z.B. in Wohnräumen, Büros und Industrieanlagen.
Stellen Sie vor der Inbetriebnahme sicher, dass das Gerät den
geltenden Vorschriften entspricht, um eine ordnungsgemäße
Funktion zu gewährleisten.
SICHERHEITSHINWEISE
Nehmen Sie die Anlage vor Beginn der Arbeit vom Netz!
Sämtliche Installationsarbeiten und Verkabelungen am Regler
dürfen nur im abgeschalteten Zustand durchgeführt werden.
Das Gerät darf nur von qualifiziertem Personal angeschlossen
und in Betrieb genommen werden. Die geltenden
Sicherheitsvorschriften sind unbedingt einzuhalten.
Die Regler sind weder Spritzwasser- noch Tropfwasserfest und
sollten deshalb nur an einer trockenen Stelle montiert werden.
Vertauschen Sie auf keinen Fall die Anschlüsse für die
Sensoren und die 230 V-Anschlüsse. Dies kann zu
lebensgefährlichen Elektroschocks oder zur Zerstörung des
Gerätes sowie der angeschlossenen Sensoren und Geräte
führen.
INHALTSVERZEICHNIS
HAUPTMERKMALE ................................................................. 19
TECHNISCHE DATEN ............................................................ 20
DARSTELLUNG (Display, Tasten) .......................................... 20
1 Einstell-Assistent .................................................. 21
2 Service ................................................................. 22
2.1 Sprache ................................................................ 22
2.2 Zeit & Datum ........................................................ 22
2.3 System ................................................................. 22
2.3.1 System 1 .............................................................. 22
2.3.2 System 2 .............................................................. 22
2.3.3 System 3 .............................................................. 23
2.3.4 System 4 .............................................................. 23
2.3.5 System 5 .............................................................. 23
2.3.6 System 6 .............................................................. 24
2.3.7 System 7 .............................................................. 24
2.3.8 System 8 .............................................................. 24
2.4 Einstellung Ausgang............................................. 24
2.4.1 P1 ......................................................................... 24
2.4.2 P2 ......................................................................... 25
2.4.3 Pumpe P3 ............................................................ 26
2.5 Einstellung Eingang ............................................. 27
2.5.1 Ohne Durchflussmesser ....................................... 27
2.5.2 Grundfos Sensoren .............................................. 27
2.5.3 Durchflussmessung (Impuls-Meter oder Flow-
Meter) 28
2.5.4 Temperatursensor ................................................ 28
2.6 Energie-Bilanzierung: ........................................... 28
2.6.1 Solarenergie ......................................................... 28
2.6.2 2. Energie ............................................................. 29
2.7 Schutzfunktionen .................................................. 29
2.7.1 Max Temp ............................................................ 30
2.7.2 Hitzeschutz ........................................................... 30
2.7.3 Kühlung ................................................................ 30
2.7.4 Rückkühlung ........................................................ 30
2.7.5 Frostschutz ........................................................... 30
2.8 °C / °F .................................................................. 30
2.9 Röhrenkollektor .................................................... 30
2.10 Werkseinstellungen: ............................................. 30
3 Menü Einstellungen .............................................. 30
3.1 Maxtemp Speicher1 ............................................. 30
3.2 dTOn Speicher1 ................................................... 30
3.3 dTOff Speicher1 ................................................... 30
3.4 dTFs: maximale Drehzahl .................................... 31
3.5 Mindesttemperatur Kollektor ................................ 31
3.6 Maxtemp Speicher2 ............................................. 31
3.7 dTOn Speicher2 ................................................... 31
3.8 dTOff Speicher ..................................................... 31
3.9 dTOn rücklauf ....................................................... 31
3.10 dTOff rücklauf ....................................................... 31
ZUSATZFUNKTIONEN ............................................................ 31
3.11 Thermostatfunktion .............................................. 31
3.11.1 Start...................................................................... 31
3.11.2 Hysterese ............................................................. 31
3.11.3 Verzögerung ......................................................... 31
3.11.4 Legionellenschutz................................................. 31
3.11.5 Timer .................................................................... 31
3.12 Kühlfunktion ......................................................... 32
3.12.1 Einschaltung der Kühlung .................................... 32
3.12.2 Kühlhysterese ...................................................... 32
3.13 Differenzregelung ................................................. 32
3.13.1 Max Kalt Speicher ................................................ 32
3.13.2 Min Warm Speicher .............................................. 32
3.13.3 dT On ................................................................... 32
3.13.4 dT Off ................................................................... 32
3.14 Funktion Antistagnation ........................................ 32
3.14.1 Einschaltebene ..................................................... 32
3.14.2 Abschaltebene ..................................................... 32
4 Menü Betrieb ........................................................ 33
4.1 Automatikbetrieb und Ausgeschaltet .................... 33
4.2 Funktion Schornsteinfeger ................................... 33
4.3 Test manuell ......................................................... 33
5 Menü Betriebsstunden ......................................... 33
6 Menü Temperaturen ............................................. 34
7 Spezialfunktionen ................................................. 34
7.1 Festsitzschutz der Pumpe .................................... 34
7.2 Dimmerfunktion .................................................... 34
7.3 Sicherheitsfunktion ............................................... 34
8 Sonstiges ............................................................. 34
9 Notizen ................................................................. 35
19
Menüstruktur
Service
Deutsch „Sprache“
Zeit und Datum
o Zeit
o Datum
o 24/12H Uhr
o DST (Sommerzeit)
System
o System 1 - 8
o Systemparameter (falls verfügbar)
Einstellung Ausgänge
o P1 „Informationen zur Verwendung“
o P2 „Informationen zur Verwendung“
o P3 „Informationen zur Verwendung“
Einstellung Eingänge
o Ohne Durchflussmesser
D-Fluss (L/min)
o Grundfos Sensoren
GDS1
„Sensorauswahl“
GDS2
„Sensorauswahl“
o Impuls-Durchflussmesser
T6
Liter / Impuls
o Temperatursensoren
T1- T5
Kalibrierung (Pt-1000)
Energie-Bilanzierung
o Solarenergie
Einstellungen
o 2. Energie
Einstellungen
Schutzfunktionen
o Max Temp.
o Hitzeschutz
Hitzeschutz Temp
o Kühlung
Max Temp
o Rückkühlung
Min Temp
o Frostschutz
Frostschutz Temp
°C/°F
Röhrenkollektoren
Werkseinstellungen
Einstell-Assistent
o Konfigurationsreihenfolge
Einstellungen
Maxtemp Speicher1
dT.ON Speicher1
dT OFF Speicher1
„Nur in Systemen mit 2 Speichern verfügbar“
Maxtemp Speicher2
dT.ON Speicher2
dT OFF Speicher2
„Nur in System 6 verfügbar”
dT.ON Rücklauf
dT OFF Rücklauf
dT FS
Min Temp Koll.
„Nur verfügbar, wenn P3 als Zusatzfunktion
verwendet wird”
Einstellungen der Zusatzfunktionen
Betrieb
Automatik
Aus
Schornsteinfeger
Test manuell
Betriebsstunden
Betrieb
dT
Leistung
Energie
SD-Karte
Temperaturen
T1
T2
T3
T4
T5
HAUPTMERKMALE
- Großes grafisches Display mit Hintergrundbeleuchtung
- Einfache menügeführte Bedienung (Scroll-Menü mit 4
Tasten)
- Mehrere Sprachversionen
- SD-Karten-Schnittstelle zum Speichern erfasster Daten
(Temperaturen, Leistung, Energie, Zeitbetrieb…) und
Parameter
- 2 Energiebilanzierungen (1 x für Solarenergie, 1 x frei
belegbar)
- 1 Busverbindung (RJ45) für das Erweiterungsmodul
(MULTIPLEX) sowie Kommunikationsanschluss
- Grafische Darstellung von Temperatur, Leistung, Energie…
- 8 Betriebssysteme. Optional mit zahlreichen
Zusatzfunktionen
- 5 Eingänge für Temperatursensoren (Typ PT1000)
- 1 logischer Eingang für Impuls-Durchflussmesser (für
Energiemessung)
- 2 analoge Eingänge für Grundfos Direktsensoren (Durchfluss
bzw. Druck mit Temperatursignal)
- 2 Pumpenausgänge (Standard oder PWM) mit Festsitzschutz
der Pumpe
- 1 Zusatzanschluss (zur Steuerung der Nachheizung, eines
Kühlsystems...)
- Automatik, Ausgeschaltet, Test manuell und Funktion
Schornsteinfeger
- Automatische Prüfung der Sensoren (Kurzschluss und
Unterbrechung)
- Kollektorschutz (Frostschutz und Überhitzungsschutz)
- Permanente Datenspeicherung
20
TECHNISCHE DATEN
Betriebstemperatur
0°C 50°C
Elektrische Schutzart
Installationsklasse
Verschmutzungsgrad
IP20
KLASSE II
2
Sicherung
Stromversorgung
Max. Stromverbrauch
(alle Ausgänge aktiviert)
5AT 230 V~ (5 x 20 mm)
230 V~ +/- 10 % 50 Hz
4,7 A (max. 1080 W)
Ausgänge:
P1 (Hauptpumpe mit Standard-
oder PWM-Drehzahlregelung):
P2 (Pumpe mit Standard- oder
PWM-Drehzahlregelung;
Ventil):
P3 (Nachheizung, Kühlung ...)
Triac max.1 A 230 V~.
Minimale Leistung > 1 W
Triac max. 1A 230 V~
Minimale Leistung > 1 W
Relais max. 2 A 230 V~
* Höherer
Energieverbrauch: nur
möglich mit externem
Energierelais
Eingänge:
T1 (Kollektor1):
T2 (Speicher1):
T3 (Zusatzsensor):
T4(Zusatzsensor, Speicher2,
Kollektor2):
T5 (Kollektor-Rücklauf):
T6 (Durchflusssensor):
GDS1 u. GDS2 (Grundfos-
Sensoren):
Durchflusssensor und
Drucksensor
Typ PT 1000
Typ PT 1000
Typ PT 1000
Typ PT 1000
Typ PT 1000
Impulstyp (Niederspannung
5 V)
Analog
(Grundfos VFS, RPS)
Im Lieferumfang enthaltene
Sensoren:
2 Kollektor-Sensoren (rotes
Silikonkabel)
1 Speichersensor (graues
Kunststoffkabel)
1 Zusatzsensor (graues
Kunststoffkabel)
PT1000 (1,5 M 180°C)
PT1000 (3 M 105°C)
PT1000 (3 M 105°C)
Software-Version
Wird beim Einschalten
angezeigt.
Ab Version v1005xx
DARSTELLUNG (Display, Tasten)
1: Vereinfachte Darstellung der Installation
- Sich drehende Pumpensymbole zeigen an, dass
die Pumpen aktiv sind.
- Füllung der Dreiecke im Ventilsymbol zeigt den
Kreislauf an.
2: Solaranlage in Betrieb.
3: Der SD-Kartenspeicher ist aktiv.
4: Temperatur der einzelnen Sensoren, Anzeige der
Pumpengeschwindigkeit, Leistung und der gespeicherten
Energie
A: Tastenbelegung
Nach oben oder Plus-Taste (+)
Nach unten oder Minus-Taste (-)
Nach links (◄)
Nach rechts (►)
Übersicht Reglerinformationen:
In einer Informationsanzeige werden die Zustände aller
Temperatursensoren und Ausgänge angezeigt, die mit dem
Regler verbunden sind.
Drücken Sie in der Hauptanzeige einmal auf die Taste (◄) für
die Sofortanzeige. Die Aus- und Eingangsanzeige wird eine
Minute lang angezeigt. Drücken Sie zu einem beliebigen
Zeitpunkt die Taste (►), um zur Hauptanzeige
zurückzukehren.
Hauptmenü
Mit der Taste (►) das Navigations-Menü öffnen.
(Das aktive Menü steht auf schwarzem Hintergrund ganz oben
auf dem Display.)
Im Navigations-Menü den Cursor „„ mit den Tasten (+) oder (-
) auf ein Untermenü bewegen und dieses mit der Taste (►)
öffnen.
Die Taste (◄) führt aus jedem Menü zurück zum vorherigen
Menü.
* ACHTUNG:
Um spätere Änderungen der Installation zu vermeiden, ist es
nach 4 Stunden nicht mehr möglich, die Installationsparameter
(Systeme und Extra-Funktionen) nach Anschluss des Reglers
ans Stromnetz zu ändern. Vor dem Ändern dieser Parameter
muss der Solarregler vom Netz genommen und wieder
angeschlossen werden. Dabei werden keine Einstellungen
gelöscht.
4
1 2
3
T1_ _
_°C
T2_ _
_°C
T3_ _
_°C
T4_ _
_°C
P1_ _ _
%
_ _ _ kW
_ _ _
kWh
T1
T4
T2
T3
A
SD
 Informationen -
T1 xxx°C T2 xxx°C T3 xxx°C
P1 xxx% P2 xxx% P3 x
 Informationen -
Service
Einstellungen
Betrieb
Betriebsstunden
Temperaturen
21
Alle anderen Parameter können nach 4 Stunden geändert
werden, um das System zu optimieren.
1 Einstell-Assistent
Im Menü "Einstell-Assistent" können Sie die Hauptparameter
des Solarreglers nach der Erstinstallation einfacher
konfigurieren.
Schalten Sie den Regler ein, und warten Sie, bis die
Initialisierungssequenz abgeschlossen ist. Wenn die
Hauptanzeige erscheint, drücken Sie auf die Taste (►), um
das Menü "Service" zu öffnen. Blättern Sie anschließend Sie
im Menü nach unten, und wählen Sie die Zeile "Einstell-
Assistent". Drücken Sie die Taste (►) einmal, um in die
Schnellstartkonfiguration zu wechseln.
Das Reglermenü hilft bei der Konfiguration der
Hauptparameter, und Sie werden aufgefordert, den
Parameterwert über die Taste (+) bzw. (-) einzustellen.
Drücken Sie die Taste (►), um die Anzeigeneinstellung zu
bestätigen und zum nächsten Parameter zu wechseln.
Der Regler kehrt automatisch zum Hauptmenü zurück, wenn
die Konfiguration abgeschlossen ist.
Schritte im Menü Einstell-Assistent:
1/ Sprachauswahl
- Wählen Sie mit den Tasten (+) und (-) Ihre Sprache, und
drücken Sie zur Bestätigung die Taste (►).
2/ Zeit- und Datumseinstellung
- Stellen Sie die Stundenangabe mit den Tasten (+) und (-) ein,
und drücken Sie zur Bestätigung die Taste (►).
- Stellen Sie die Minuten ein, drücken Sie die Taste (►), um
die Eingabe zu bestätigen und in die nächste Zeile zu
wechseln.
Der Regler springt automatisch zur Datumszeile. Gehen Sie
dort wie folgt vor:
- Stellen Sie die Monatsangabe mit den Tasten (+) und (-) ein,
und drücken Sie zur Bestätigung die Taste (►).
- Stellen Sie den Tag mit den Tasten (+) und (-) ein, und
drücken Sie zur Bestätigung die Taste (►).
- Stellen Sie das Jahr mit den Tasten (+) und (-) ein, und
drücken Sie zur Bestätigung die Taste (►).
Der Regler springt automatisch in die Zeile für die Einstellung
des Zeitformats. Stellen Sie es mit den Tasten (+) und (-) ein,
und drücken Sie zur Bestätigung die Taste (►).
Sie können ggf. die Sommerzeit einstellen. Drücken Sie dazu
die Taste (+) bzw. (-), und drücken Sie zum Bestätigen die
Taste (►).
3/ Systemauswahl
- Wählen Sie das gewünschte System mit den Tasten (+) und
(-) ein, und drücken Sie zur Bestätigung die Taste (►).
Anschließend werden Sie aufgefordert, die ausgewählten
Systemparameter einzustellen. Stellen Sie die
Systemparameter mithilfe der Tasten (+) bzw. (-) ein, und
drücken Sie die Taste (►), um die Eingabe zu bestätigen und
mit dem nächsten Schritt der Konfiguration fortzufahren.
4/ Konfiguration der Ausgänge
Wählen Sie das an den Ausgang des Reglers angeschlossene
Gerät (z.B. Standardpumpe, PWM-Pumpe oder 3-Wege-Ventil)
mithilfe der Tasten (+) und (-) aus, und drücken Sie die Taste
(►), um die Auswahl zu bestätigen und die Konfiguration
abzuschließen.
Hinweis: Abhängig vom jeweiligen System werden Sie
aufgefordert, auch den Ausgang P2 zu konfigurieren.
Der Regler ist jetzt eingerichtet.
Bemerkung:
Sie können das Menü "Einstell-Assistent" erneut starten und
die oben beschriebenen Konfigurationsschritte erneut
ausführen. Alternativ können Sie, wenn Sie bei der
Konfiguration eine fehlerhafte Einstellung vorgenommen
haben, über die normale Menüstruktur direkt auf einen
bestimmten Parameter zugreifen.
 Service -
Deutsch
Zeit und Datum
System
Einstellung Ausg.
Einstellung Eing.
Energie Bilanzierung
Schutzfunktionen
Grad °F
Röhrenkollektoren Nein
werkseinstell. Nein
Einstell-Assistent
 Service --- -
Deutsch -
Zeit und Datum
System
Einstellung Ausg.
Einstellung Eing.
Energie Bilanzierung
Schutzfunktionen
 Zeit und Datum --- -
Zeit 08:25
Datum 02/03/2011
Samstag
24/12H Uhr 24H
D.S.T. Ja
P1
System
1
T1
T2
T1 _ _ _°C
T2 _ _ _°C
P1 _ _ _ %
 Pumpe 1 --- -
Typ Std Pumpe
Drehzahlregelung Grun
Min Drehzahl P. 0%
Max Drehzahl P. 100%
T1_ _ _°C
T2_ _ _°C
T3_ _ _°C
T4_ _ _°C
P1_ _ _ %
_ _ _ kW
_ _ _ kWh
T2
T3
SD
T1 T4
22
2 Service
2.1 Sprache
- Mit der Taste (+) oder (-) die Zeile „Deutsch“ wählen, danach
mit der Taste (►) die Zeile markieren.
- Mit den Tasten (+) und (-) eine der folgenden Sprachen
auswählen: Englisch, Deutsch, Französisch, Spanisch,
Italienisch, Niederländisch, Ungarisch und Portugiesisch.
2.2 Zeit & Datum
- Mit der Taste (+) oder (-) auf die Zeile „Datum & Zeit“ gehen
und mit der Taste (►) das entsprechende Untermenü öffnen.
- Mit den Tasten (+) oder (-) Datum und Zeit einstellen und den
Wert mit der Taste (►) bestätigen.
Zeit - Drücken Sie einmal die Taste (►), um die Stunden
einzustellen.
- Drücken Sie erneut die Taste (►), um die Minuten
einzustellen.
- Drücken Sie zweimal die Taste (◄), um zur
Zeilenauswahl zurückzukehren.
Datum
- Drücken Sie einmal die Taste (►), um den Monat
einzustellen.
- Drücken Sie zweimal die Taste (►), um den Tag
einzustellen.
- Drücken Sie dreimal die Taste (►), um das Jahr
einzustellen.
- Drücken Sie dreimal die Taste (◄), um zur
Zeilenauswahl zurückzukehren.
* Der Tag wird automatisch angezeigt.
24/12H Uhr
- Drücken Sie einmal die Taste (►), um das
Uhrzeitformat einzustellen.
D.S.T. (Sommerzeit)
- Sommerzeit - Wählen Sie diese Funktion aus, um
die automatische Umstellung der Uhr im Winter und
Sommer zu aktivieren.
Bemerkung: Bei einem Stromausfall wird die Uhrzeit für
24 Std. gespeichert, danach muss die Uhr neu eingestellt
werden.
2.3 System
Wenn die Zeile ausgewählt ist, drücken Sie die Taste (►), um
das Untermenü zu öffnen. Wählen Sie unter den 8
Systemoptionen, indem Sie die Taste (►) drücken, und
wählen Sie Ihr System mit den Tasten (+) und (-) aus. Sie
können zusätzliche Funktionen hinzufügen, indem Sie den
Ausgang P3 (siehe "Konfiguration der Ausgänge" in Kapitel
2.4) verwenden.
Wenn diese Zeile markiert ist, das Untermenü mit der Taste
(►) öffnen.
Dort stehen 8 Systeme und verschiedenen Zusatzfunktionen
zur Auswahl.
2.3.1 System 1
Grundsystem bestehend aus: 1 Speicher, 1 Pumpe, 1
Kollektorfeld und 2 Sensoren.
Zu diesem System können Zusatzfunktionen mit 1 oder 2
Sensoren hinzugefügt werden (Thermostat, Kühlfunktion,
Antistagnation oder Differenzregelung).
Der Speicher1 wird beladen, wenn die Temperaturdifferenz
dt“ zwischen Kollektor (T1) und Speicher1 (T2) erreicht wird.
2.3.2 System 2
System bestehend aus: 2 Speichern, 1 Pumpe, 1 Ventil, 1
Kollektorfeld und 3 Sensoren. In diesem System kann noch
eine Funktion mit 1 Sensor hinzugefügt werden (Thermostat,
Kühlung, Antistagnation).
Die Speicher werden beladen, wenn die Temperaturdifferenz
dt“ zwischen Kollektor (T1) und den Speichern (T2, T4)
erreicht wird.
Man kann zwischen verschiedenen Möglichkeiten der
Beladung der beiden Speicher wählen. Mehr Informationen
dazu: siehe Abschnitt „Prio Sp.
Nur in Systemen mit zwei Speichern verfügbar (2 und 3).
 Service --- -
Deutsch -
Zeit und Datum
System
Einstellung Ausg.
Einstellung Eing.
Energie Bilanzierung
Schutzfunktionen
Grad °F
Röhrenkollektor Nein
Werkseinstell. Nein
Schnellstartmenü
 System --- -
System 1
P1
System
1
T1
T2
T1 _ _ _°C
T2 _ _ _°C
P1 _ _ _ %
P1
P2
System
2
T1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
T2 T4
 System --- -
System 2
Prio Sp. Keine V
Prio Zeit Laden 15m
Prio Zeit Pause 2m
23
Keine Priorität
Es wird keine Priorität zwischen den Speichern ausgewählt.
Die beiden Speicher werden unabhängig beladen. Die einzige
Bedingung zum Beladen der Speicher ist, dass der Wert „dt
erreicht wird
1“ Der Vorrangspeicher ist der Speicher1, der von Sensor T2
verwaltet wird. Der Speicher wird in der Hauptanzeige mit einer
kleinen Nummer „2“ dargestellt.
2“ Der Vorrangspeicher ist der Speicher2, der von Sensor T4
verwaltet wird. Der Speicher wird in der Hauptanzeige mit einer
kleinen Nummer „2“ dargestellt.
Wenn der Vorrangspeicher ausgewählt wird, wird dieser
Speicher vorrangig beladen und der zweite Speicher wird nur
beladen wenn:
- der Vorrangspeicher den Wert „Maxtemp Speicher(x)
erreicht. Der Wert kann im Menü „Einstellungen“ festgesetzt
werden.
- Wenn die Kollektortemperatur zu niedrig ist, um den
Vorrangspeicher zu beladen In diesem Fall wird der
Nachrangspeicher beladen mit der Zyklusfunktion, die mit den
folgenden Parametern definiert wird. Diese Funktion ermöglicht
das „Zurückschalten“ vom Nachrangspeicher auf den
Vorrangspeicher.
(1 Zyklus = „Prio Zeit Pause“ + „Prio Zeit Laden“)
Bemerkung:
Solange der Wert „dtMax Speicher(x)“ des Vorrangspeichers
nicht erreicht wird, wird der Vorrangspeicher beladen.
Prio Zeit Pause
Zeitdauer der Pause (AUS Zeit), für die Zyklusfunktion.
- Um die Zeitdauer einzustellen, durch Drücken der Taste (►)
die Zeile markieren und mit der Taste (+) oder (-) den Wert
verändern. (Einstellbar von 1 bis 30 min, mit der
Werkseinstellung von 2min).
Prio Zeit Laden
Zeitdauer zum Laden (AN Zeit), bei der Zyklusfunktion.
- Zum Ändern der Zeitdauer mit der Taste (►) auf die Zeile
gehen und den gewünschten Wert mit der Taste (+) oder (-)
wählen. (Einstellbar von 1 bis 30 min, mit der Werkseinstellung
von 15min)
2.3.3 System 3
System bestehend aus: 2 Speichern, 2 Pumpen, 1
Kollektorfeld und 3 Sensoren.
In diesem System kann noch eine Funktion mit 1 Sensor
hinzugefügt werden (Thermostat, Kühlung, Antistagnation).
Die Speicher werden beladen, wenn die Temperaturdifferenz
dt“ zwischen Kollektor (T1) und den Speichern (T2, T4)
erreicht wird.
Man kann zwischen verschiedenen Möglichkeiten der
Beladung der beiden Speicher wählen. Mehr Informationen
dazu: siehe „Prio Sp.
2.3.4 System 4
System bestehend aus: 1 Speicher, 1 Pumpe, 1 Ventil, 2
Kollektorfelder in unterschiedlicher Ausrichtung (Ost/West) und
3 Sensoren. In diesem System kann noch eine Funktion mit 1
Sensor hinzugefügt werden (Thermostat, Kühlung,
Antistagnation).
Der Speicher1 wird beladen, wenn die Temperaturdifferenz
dt“ zwischen Kollektorfeld (T1, T4) und Speicher1 (T2)
erreicht wird. Die Richtung des Umschaltventils (P2) wird vom
wärmeren Kollektorfeld (T1) bzw. (T4) bestimmt.
2.3.5 System 5
System bestehend aus: 1 Speicher, 2 Pumpen, 2
Kollektorfelder in unterschiedlicher Ausrichtung (Ost/West) und
3 Sensoren. In diesem System kann noch eine Funktion mit 1
Sensor hinzugefügt werden (Thermostat, Kühlung,
Antistagnation).
Der Speicher1 (T2) wird beladen, wenn die
Temperaturdifferenz „dt“ zwischen den Kollektoren und
Speicher1 erreicht wird.
Der Speicher wird über den wärmeren Kollektor (T1 oder T4)
beladen, wenn der Parameter „P1 || P2 = nein“ ist
(Standardwert).
Der Speicher kann über beide Kollektorfelder gleichzeitig
beladen werden, wenn der Parameter „P1 || P2 = ja“ ist.
Funktion P1 // P2
Diese Funktion kann verwendet werden, um die beiden
Pumpen P1 und P2 gleichzeitig arbeiten zu lassen (der
Speicher wird über die beiden Kollektoren gefüllt).
- Um die Funktion zu aktivieren, mit den Tasten (+) oder (-) auf
die Zeile „P1 // P2“ gehen, Taste (►) drücken, um die Option
Ja“ mit den (+) oder (-) zu aktivieren.
P1
P2
System
3
T1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
T2 T4
P2
P1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
System
4
T1 T4
T2
P1 P2
System
5
T1 T4
T2
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
 System --- -
System 5
P1||P2 Nein
24
2.3.6 System 6
System bestehend aus: 1 Kollektorfeld, 1 Speicher, 1 Pumpe,
1 Ventil und 4 Sensoren.
In diesem System kann noch eine Funktion mit 1 Sensor
hinzugefügt werden (Thermostat, Kühlung, Antistagnation).
Der Speicher1 wird beladen, wenn die Temperaturdifferenz
dt“ zwischen Kollektor (T1) und Speicher1 (T2) erreicht wird.
Vorwärmen Heizkreisrücklauf:
Wenn die Temperaturdifferenz „dt“ zwischen Speicher1 (T3)
und Rücklauftemperatur (T4) erreicht wird, erfolgt das
Vorwärmen des Heizungsrücklaufs über Speicher1. Dies spart
Energie auf der Seite des externen Heizsystems*.
2.3.7 System 7
System bestehend aus: 1 Kollektorfeld ,1 Speicher, 2 Pumpen
1 externer Plattenwärmetauscher.
In diesem System kann noch eine Funktion mit 1 Sensor
hinzugefügt werden (Thermostat, Kühlung, Antistagnation und
Differenzreglung).
Der Speicher1 wird beladen, wenn die Temperaturdifferenz
dt“ zwischen Kollektor (T1) und Speicher1 (T2) erreicht wird.
Die Zeitverzögerung für das Einschalten der Pumpe zwischen
Plattenwärmetauscher und Speicher1 kann ausgewählt
werden. Der Standardwert ist 1 Minute. Dies gibt dem
Plattenwärmetauscher Zeit zum Warmlaufen.
Verzögerung (Delay) P2
Steht nur für System 7 zur Verfügung.
- Zeitverzögerung für das Einschalten der Pumpe P2, nachdem
Pumpe P1 gestartet ist.
- Mit den Tasten (+) oder (-) die Zeile „Delay P2
(Verzögerung)“ wählen und mit (►) markieren.
- Nun kann man die Verzögerungszeit der Pumpe P2 mit (+)
oder (-) ändern. (Einstellbar von 0 bis 30 Minuten, mit der
Werkseinstellung von 1 Minute)
2.3.8 System 8
System bestehend aus: 1 Speicher, 2 Pumpen, 1
Kollektorfeld und 3 Sensoren und 1 Plattenwärmetauscher.
In diesem System kann noch eine Funktion mit 1 Sensor
hinzugefügt werden (Thermostat, Kühlung, Antistagnation).
Pumpe P1 startet, wenn die Temperaturdifferenz „dt“ zwischen
dem Kollektor (T1) und dem Speicher1 (T2) erreicht wird.
2.4 Einstellung Ausgang
- In diesem Menü können Sie einen bestimmten Ausgangstyp
und die Einstellungen des Geräts konfigurieren, das mit allen
anderen Ausgängen des Reglers verbunden ist (z.B.
Hocheffizienzpumpe oder Standardpumpe, mit oder ohne
Drehzahlregelung, Energierelais, usw.).
Sie können außerdem die "freien" Ausgänge für eine
Zusatzfunktion verwenden (Thermostat, Kühlung,
Differenzregelung, Antistagnation, Booster...).
Bemerkung: Die "freien" Ausgänge werden als "Außer Betrieb"
gekennzeichnet.
2.4.1 P1
Hauptpumpenausgang. Dieser Ausgang wird immer für die
Verwaltung des Solarkreislaufs verwendet.
Sie können, wenn große Pumpen erforderlich sind, zwischen
Hocheffizienz-PWM-Pumpe, Standardpumpe oder
Leistungsrelais wählen.
Zum Ändern der gewählten Pumpe mit der Taste (►) auf die
Zeile gehen und den gewünschten Wert mit der Taste (+) oder
(-) wählen.
PWM Pumpe
Wenn Sie eine PWM-Pumpe anschließen, können Sie
zwischen 3 Marken wählen: GRUNDFOS, WILO und Lowara
Laing.
Die Drehzahl wird über die PWM-Steuerung geregelt:
"ViH = ~11VDC ViL = <0,5V VDC" mit der Signalfrequenz ~
250 Hz”.
Kompatibilitätsbeispiel:
- Typ GRUNDFOS SOLAR PM
- Typ WILO STRATOS
- Typ Lowara Laing ECOCIRC E4 PWM1
P2
*
P1
System
6
T1
T1 _ _ _°C
T2 _ _ _°C
T3 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
T2
T4
T3
P1
P2
System
7
T1
T1 _ _ _°C
T2 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
T2
 System --- -
System 7
Verz. P2 2min
P2
P1
System
8
T1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
T2
T4
 Einstellung Ausg.- -
P1 Benutzt von System
P2 “Außer Betrieb”
P3 “Außer Betrieb”
 Pumpe 1 --- -
Typ PWM Pumpe
Drehzahlregelung Grundfos
Min Drehzahl P. 0%
Max Drehzahl P. 100%
25
Sie können die Mindest- und Höchstdrehzahl der Pumpe in
Prozent angeben (einstellbar von 0 bis 100%).
Die Nenndrehzahl der Pumpe wird variabel gesteuert, wenn
der Wert von "dt" im Bereich von "dtFs" und "dtMin" liegt.
dtFS => dT-Skala der Drehzahlabweichung.
Mithilfe der Drehzahlregelung der Pumpen kann die
Energiegewinnung der Kollektoren maximiert werden.
Erläuterung der PWM-Drehzahlregelung:
Standardpumpe
Wird eine Standardpumpe angeschlossen, kann die Drehzahl
der Pumpe geregelt werden. In diesem Fall erfolgt die
Drehzahlregelung über eine Pulspaketfunktion.
Sie können die Mindest- und Höchstdrehzahl der Pumpe in
Prozent angeben (einstellbar von 30 bis 100%).
Die Nenndrehzahl der Pumpe wird variabel gesteuert, wenn
der Wert von "dt" im Bereich von "dtFs" und "dtMin" liegt.
Diese Funktion ist eine Alternative zur Hocheffizienzpumpe
(PWM). Wenn Sie den Wirkungsgrad der Solarinstallation
maximieren wollen, sollte eine Hocheffizienz-PWM-Pumpe
eingesetzt werden.
Wird die Drehzahlregelungsfunktion nicht benötigt, wählen Sie
die Option "Drehzahlregelung Nein".
Erläuterung der Pulspaket-Drehzahlregelung:
Wichtig:
Da die Drehzahlregelung über Pulspakete erfolgt, können im
Hydraulikkreislauf Geräusche auftreten. Prüfen Sie die
Kompatibilität der Hydraulikkreislaufs (Anschlüsse,
Verrohrung), bevor Sie diesen Drehzahlregelungstyp
auswählen.
Relais / Ventil
Wenn es erforderlich ist, eine große Pumpe für die
Solarinstallation an ein großes Kollektorfeld anzuschließen
(d.h. die Pumpleistung ist größer als der maximal angegebene
Ausgang des Reglers), können Sie die Pumpe über ein
externes Energierelais regeln lassen.
Bemerkung: Für diesen Ausgangstyp ist keine
Drehzahlregelungsfunktion verfügbar.
2.4.2 P2
Ausgang P2 ist als "Benutzt von System" gekennzeichnet. Sie
können seine Eigenschaften wie oben für P1 beschrieben
ändern.
Wenn der Ausgang dazu verwendet wird, ein Richtungsventil
zu verwalten (in System 2 und 4), ist keine Auswahl möglich.
Um den Pumpentyp zu ändern, drücken Sie die Taste (►), um
die Zeile hervorzuheben, und wählen Sie den gewünschten
Typ mit der Taste (+) bzw. (-).
Wenn der der Ausgang "Außer Betrieb" ist, können Sie den
Ausgang möglicherweise als Booster-Pumpe der Hauptpumpe
in System 1 verwenden.
Diese Funktion ist nützlich, wenn Sie ein "Rückfluss-System"
verwenden, damit die primäre Pumpe P1 für die Initialisierung
des Kreislaufs der Wärmeübertragungsflüssigkeit verwendet
werden kann.
In diesem Beispiel wird Pumpe 2 normal in Serie mit der
Hauptpumpe P1 installiert.
- Sie können die Dauer für die Laufzeit von P2 mithilfe der
Tasten (+) und (-). einstellen (einstellbar zwischen 1 und 10
Minuten)
Erläuterung der Booster-Funktion:
Beispiel:
dTMin
dTMax
100%
Einschaltung
der Pumpe
dTFs
dTFs
Geregelter
Drehzahlbereich
0%
Einschaltung
der Pumpe
dTMin
dTMax
100%
Min Drehzahl
Pumpen
dTFs
dTFs
Geregelter
Drehzahlbereich
30%
 Pumpe 2 --- -
P2 “Benutzt von System”
Typ Std Pumpe
Drehzahlregelung Nein
 Pumpe 2 --- -
P2 Booster
Dauer Boost 2min
Speicher1
T2 (°C)
dTMin
dTMax
P1
Kollektor
T1 (°C)
Maxtemp
Speicher1
dTMax
dT = T1
T2
100%
0%
dTMax
Boost-
Dauer
P2
T1
P1
T2
Zusatzfunktion für
Pumpensteuerung einer
zweiten Pumpe in Serie mit
P1 in Verbindung mit
Außenbrenner.
P2
26
2.4.3 Pumpe P3
P3 ist ein zusätzlicher Ausgang, der für eine weitere
Zusatzfunktion verwendet werden kann und der normalerweise
in Kombination mit der Solaranlage oder vollständig
unabhängig verwendet wird. Sie können, abhängig von der
ausgewählten Systemkonfiguration, zwischen verschiedenen
Funktionen wählen.
2.4.3.1 Thermostatfunktion Heizen
Diese Funktion wird mit einem Zusatzsensor (T3) zum
Regeln der Zusatzheizpumpe (P3) verwendet.
(Siehe Funktionsdiagramm in Abschnitt 2.13
Zusatzfunktionen)
Möglichkeiten:
- Pumpensteuerung für Heizöl- oder Gasbrenner…
- Elektrischer Heizstab im Solarspeicher
(Achtung: In diesem Fall muss ein externes Vorschaltrelais für
den Ausgang verwendet werden!)
Beispiel:
Alle für diese Funktion verfügbaren Einstellungen sind über
das Einstellungsmenü zugänglich (siehe Erklärung der
Funktionen in Abschnitt "Einstellungen" in Kapitel 2).
2.4.3.2 Thermostatfunktion Kühlen
Diese Funktion wird mit einem Zusatzsensor (T3) zum
Kühlen des Haupt-Solarspeichers mit einem zusätzlichen
Wärmetauscher verwendet
(z.B. für einen Swimming-Pool).
(Siehe Funktionsdiagramm in Abschnitt 2.14
Zusatzfunktionen)
Beispiel:
Alle für diese Funktion verfügbaren Einstellungen sind über
das Einstellungsmenü zugänglich (siehe Erklärung der
Funktionen in Abschnitt "Einstellungen" in Kapitel 2).
2.4.3.3 Funktion Differenzreglung
Diese Funktion wird mit Zusatzsensoren (Tkalt=T3,
Twarm=T4) zum Regeln der Zusatzheizpumpe oder zum
llen eines Speichers verwendet.
Das Füllen von Tkalt=T3 wird aktiviert, wenn die
Temperaturdifferenz „dt“ zwischen Twarm=T4 und Tkalt=T3
erreicht wird.
(Siehe Funktionsdiagramm in Abschnitt 2.15
Zusatzfunktionen)
Beispiel 1:
Beispiel 2:
Alle für diese Funktion verfügbaren Einstellungen sind über
das Einstellungsmenü zugänglich (siehe Erklärung der
Funktionen in Abschnitt "Einstellungen" in Kapitel 2).
2.4.3.4 Booster-Funktion
Weitere Informationen zu dieser Funktion finden Sie im
Abschnitt über P2.
Beispiel:
Wärmetauscher
T
1
P
3
P
1
T
3
T
2
Zusatzfunktion für Pumpensteuerung
zur Erwärmung eines anderen Speichers oder Pools.
P3
P1
T2
Zusatzfunktion zur Pumpensteuerung (P3)
zum Erwärmen von „Tkalt=T3“, wenn die
Temperaturdifferenz (dt) zu „Twarm=T4“
erreicht wird.
T1
TC = T3
TW = T4
Anderes Heizsystem mit
Speicher
(Heil, Pellets,
Brennholz u.a.)
P
3
P
1
TC =
T3
T
2
Zusatzfunktion zur
Pumpensteuerung (P3) zum
Erwärmen von „Tkalt=T3“, wenn
die Temperaturdifferenz (dt) zu
„Twarm=T4“ erreicht wird.
T1
TW =
T4
T1
P1
T2
Zusatzfunktion für
Pumpensteuerung einer
zweiten Pumpe in Serie mit
P1 in Verbindung mit
Außenbrenner.
P3
Heizung
T1
P3
P1
T3
T2
Zusatzfunktion für
Pumpensteuerung in
Verbindung mit
Außenbrenner.
27
2.4.3.5 Funktion Antistagnation
Die Funktion Antistagnation wird zusammen mit der Watts-
Antistagnationseinheit verwendet, um eine Beschädigung des
Kollektors (Flüssigkeit) bei zu langer Sonneneinstrahlung zu
vermeiden, wenn die Hauptpumpe nicht in Betrieb ist (z.B. im
Sommer, wenn der Speicher bereits vollständig beladen ist).
Wenn der Solarkreislauf (T1, T4 (bei 2 Kollektorfeldern)) auf
110°C (veränderbarer Standardwert) erhitzt wird, wird der
Relaisausgang P3 und Hauptpumpe mit P1 eingeschaltet.
P3 wird an das Dreiwegeventil und den Lüfter der Watts-
Antistagnationseinheit angeschlossen.
Nachdem der Solarkreislauf auf 90°C (veränderbarer
Standardwert) gekühlt wurde, wird der Ausgang P3&P1
ausgeschaltet.
Beispiel 1:
Beispiel 2:
2.5 Einstellung Eingang
- Sie können alle am Regler verfügbaren Eingänge
konfigurieren und überwachen (digitale oder analoge
Eingänge).
2.5.1 Ohne Durchflussmesser
Geschätzter Durchflusseingang
Wenn kein Imp.-Fluss-Meter installiert ist (Werkseinstellung),
muss der Durchfluss in L/Minute eingegeben werden, der am
Durchflussmesser der Solarstation abgelesen werden kann.
Der Durchfluss an der Skala am Durchflussmesser kann
eingegeben werden, indem die Zeile „D-Fluss (L/min)“ mit der
Taste (►) markiert und der Durchfluss mit (+) und (-)
eingestellt wird. (Einstellmöglichkeit von 1 bis 100 L/min,
Werkseinstellung 10 L/min)
Wichtig:
Der Durchfluss muss abgelesen werden, wenn die Pumpe mit
100 % Drehzahl arbeitet.
2.5.2 Grundfos Sensoren
- Der Regler ist mit 2 speziellen Eingängen für analoge
GRUNDFOS-Sensoren ausgestattet (Typ VFS-
Durchflussmesser oder RPS-Druckmesser).
Der Durchflussmesser misst und überwacht die Energie,
während der Druckmesser nur den Druck im Hauptkreislauf
kontrolliert.
GDS1 (Grundfos Direct Sensor)
- Der Regler ist mit 2 speziellen Eingängen für analoge
GRUNDFOS-Sensoren ausgestattet (Typ VFS-
Durchflussmesser oder RPS-Druckmesser).
Der Durchflussmesser misst und überwacht die Energie,
während der Druckmesser nur den Druck im
Hauptkreislauf kontrolliert.
- Nach dem Wählen der Zeile auf (►) drücken, um das
Untermenü GDS1 zu öffnen.
Durchfluss und Druck lassen sich über verschiedene
Skalen einstellen.
- Zum Wählen des angeschlossenen Sensortyps mit der
Taste (►) auf die Zeile gehen und den gewünschten Typ
mit der Taste (+) oder (-) wählen.
- NC Nicht angeschlossen
- RPS 0 4 bar Druckmesser
- RPS 0 6 bar Druckmesser
- RPS 0 10 bar Druckmesser
- VFS 1 12l/min Durchflussmesser
- VFS 2 40l/min Durchflussmesser
- VFS 5 100l/min Durchflussmesser
- VFS 10 200l/min Durchflussmesser
- VFS 20 400l/min Durchflussmesser
Sensortyp: siehe Typschild am eingebauten Sensor
- Je nach gewähltem Sensor können die vom Sensor
gemessenen Werte für Temperatur, Durchfluss und Druck
sowie die berechneten Werte für Leistung und Energie in
Echtzeit angezeigt werden.
Mit Durchflusssensor „VFS“
P
3
P
1
T2
Zusatzfunktion zum Kühlen des Solarkreislaufs
mit TiSUN-Antistagnationseinheiten
T1
P3
P1
T2
Zusatzfunktion zum Entladen des Kollektors in
einen anderen freien Wärmespeicher oder
unterirdisch...
T1
 Einstellung Eingang -
Wenn kein D-Flussmesser
D-Fluss (L/min) 10
Grundfos Sensoren
GDS1
GDS2
Impuls Durchflussmess
T6
Temperatursensor
T1 xxx°C
T2 xxx°C
T3 Ausser Betrieb
T4 Ausser Betrieb
T5 Ausser Betrieb
 GDS1---- --- -
GDS1 NC
 GDS1---- --- -
GDS1 VFS 1-12 l/min
D-Fluss x,x l/min
Temp GDS1 xxx°C
* In diesem Fall muss das TiSUN-
Energierelais "LR 20 3S" am Ausgang
P3 installiert werden.
28
Mit Drucksensor „RPS
* Hinweis: Echtzeitwerte für den Durchfluss bzw. Druck
werden auf der Hauptzeile des GDS1 Menüs angezeigt.
GDS2 (Grundfos Direct Sensor)
Dieser Eingang hat dieselbe Funktion und bietet dieselben
Möglichkeiten wie der Eingang GDS1.
2.5.3 Durchflussmessung (Impuls-Meter oder Flow-
Meter)
Wenn ein Imp. Meter installiert ist (an T6 / PF), die Option
„Impuls“ wählen und
mit den Tasten (+) und (-) die Durchflusswerte in Liter/Impuls
eingeben
(Einstellmöglichkeit von 1 bis 25 L/Imp, Werkseinstellung 10
L/Imp).
Wird ein Imp. Meter zur Energiemessung verwendet,
den Sensor T5 am Kollektor-Rücklauf anschließen, um ein
genaueres Ergebnis zu erzielen.
Bemerkung: Imp. Meter nicht an T6 anschließen, wenn ein
digitaler Druckmesser oder Durchflussmesser an GDS2
angeschlossen ist!
2.5.4 Temperatursensor
In diesem Untermenü können Sie den aktuellen Status aller
Temperatursensoren anzeigen, die an den Regler
angeschlossen sind. Sie können den vom Regler gemessenen
Istwert ablesen und sehen, ob er verwendet wird bzw. ob der
Sensor defekt ist.
Drücken Sie die Taste (►), um auf die Sensorkalibrierung
zuzugreifen.
Achtung: Vor dem Einstellen des Wertes den Istwert der
Sensoren mit einem geeichten Thermometer überprüfen
(Kalibrierbereich: -3°C bis +3°C, Werkseinstellung 0°C).
2.6 Energie-Bilanzierung:
Der Regler verfügt über zwei Energie-Bilanzierungsblöcke. Sie
können für beide Blöcke Sensoren konfigurieren, die für die
Energieberechnung verwendet werden.
Berechnungslogik der Energiemessung:
Für die Energieberechnung sind mehrere Elemente
erforderlich: zwei Temperaturmesspunkte "Warm" und "Kalt",
der Durchflusswert und die Eigenschaften der
Wärmeübertragungsflüssigkeit.
2.6.1 Solarenergie
Der erste Block ist für die Berechnung der Solarenergie
reserviert. Sie können die für die Berechnung verwendeten
Sensoren auswählen.
Zum Ändern des gewählten Sensors mit der Taste (►) auf
die Zeile gehen und den gewünschten Wert mit der Taste
(+) oder (-) gemäß der Installation wählen.
Durchflusssensor
- "Auto"
Der Regler verwendet den theoretischen Durchfluss (Liter /
Minute), der in der Konfiguration der Eingänge eingegeben
wurde, sofern kein Durchflusssensor verfügbar ist.
- T6
Der Regler verwendet den Impuls-Messer, der an den Eingang
"T6" angeschlossen ist.
- "GDS1"
Der Regler verwendet den Grundfos
Strömungsdurchflusssensor "Typ VFS", sofern dieser am
Eingang GSD1 angeschlossen ist.
 GDS1---- --- -
GDS1 RPS 0 - 4 bar
Druck x,x bar
Temp GDS1 xxx°C
 T6 --- -
Impuls-Durchflussmesser Nein
 T6 --- -
Impuls-Durchflussmesser Ja
Liter / Impuls 10
 Einstellung Eing.---- -
Temperatursensor
T1 xxx°C
T2 xxx°C
T3 xxx°C
T4 Ausser Betrieb
T5 Ausser Betrieb
 T1 --- -
Pt1000
Kalibrierung 0°C
Wärmepunkt
P1
Funktionaler Einsatz für
die Berechnung der
Solarenergiebilanz.
Kältepunkt Durchflussmesser
 Solar-Energie -
Durchflusssensor Auto
Sensor warm Auto
Sensor kalt Auto
Flüssigkeit Glycol
Mixed 40%
D-Fluss xxxxm3
Energie 0kWh
Leistung 0.0kW
29
Sensor warm
- "Auto"
Der Regler wählt automatisch den entsprechenden
Wärmesensor aus, der dem verwendeten System entspricht
(Kollektorsensor T1 oder T4).
- "T1" oder "T4"
Der Regler verwendet den PT1000-Sensor T1 oder T4,
entsprechend dem vom Benutzer ausgewählten Sensor.
- "GDS1"
Der Regler verwendet das Temperatursensorelement des
Grundfos Strömungsdurchflusssensors "Typ VFS".
Sensor kalt
- "Auto"
Der Regler wählt automatisch den entsprechenden
Speichersensor aus, der dem verwendeten System entspricht
(Speichersensor T2 oder T4).
- "T5"
Der Regler verwendet den PT1000-Sensor T5.
- "GDS1"
Der Regler verwendet das Temperatursensorelement des
Grundfos Strömungsdurchflusssensors "Typ VFS".
Bemerkung: Wählen Sie nicht denselben Sensor für
"warm" und "kalt". Dies führt zu einer fehlerhaften
Energieberechnung.
Flüssigkeit
- "Wasser"
Der Regler verwendet für die Berechnung den
Wärmeübertragungskoeffizienten von Wasser.
- "Glycol"
Der Regler verwendet für die Berechnung den Wasser-Glykol-
Koeffizienten mit dem prozentualen Verhältnis, das für die
Berechnung angegeben wurde.
Mischungsparameter: einstellbar zwischen 10 % und 50 %
Glykol in der Flüssigkeit.
Durchfluss (Volumen)
- Anzeige des kumulierten Volumens in m3.
Sie können den gespeicherten Wert zurücksetzen, indem Sie
die Tasten (►) und (-) für 5 Sekunden gedrückt halten.
Energie
- Anzeige der kumulierten Energie in kWh.
Sie können den gespeicherten Wert zurücksetzen, indem Sie
die Tasten (►) und (-) für 5 Sekunden gedrückt halten.
Leistung
- Anzeige der momentanen Leistung in W.
2.6.2 2. Energie
Der zweite Energieblock kann verwendet werden, um einen
weiteren Kreislauf zu berechnen oder zu überwachen.
Dieser Kreislauf kann ein vollständig unabhängiger
Solarkreislauf sein (Energieversorgung über den
zusätzlichen Heizkessel, Energie für Brauchwasser, usw.).
Soll dieser Block verwendet werden, wählen Sie "Ja" in der
Zeile
"2. Energie".
Die Funktion ist mit dem oben beschriebenen 1. Block
identisch.
Durchflusssensor
- "Auto"
Der Regler verwendet den theoretischen Durchfluss (Liter /
Minute), der in der Konfiguration der Eingänge eingegeben
wurde, sofern kein Durchflusssensor verfügbar ist.
- T6
Der Regler verwendet den Impuls-Messer, der an den Eingang
"T6" angeschlossen ist.
- "GDS2"
Der Regler verwendet den Grundfos
Strömungsdurchflusssensor "Typ VFS", sofern dieser am
Eingang GSD2 angeschlossen ist.
Sensor warm
- "T1" bis "T5"
Der Regler verwendet den PT1000-Sensor T1 bis T5,
entsprechend dem vom Benutzer ausgewählten Sensor.
- "GDS2"
Der Regler verwendet das Temperatursensorelement des
Grundfos Strömungsdurchflusssensors "Typ VFS".
Sensor kalt
- "T1" bis "T5"
Der Regler verwendet den PT1000-Sensor T1 bis T5,
entsprechend dem vom Benutzer ausgewählten Sensor.
- "GDS2"
Der Regler verwendet das Temperatursensorelement des
Grundfos Strömungsdurchflusssensors "Typ VFS".
Bemerkung: Wählen Sie nicht denselben Sensor für
"warm" und "kalt". Dies führt zu einer fehlerhaften
Energieberechnung.
Flüssigkeit
- "Wasser"
Der Regler verwendet für die Berechnung den
Wärmeübertragungskoeffizienten von Wasser.
- "Glycol"
Der Regler verwendet für die Berechnung den Wasser-Glykol-
Koeffizienten mit dem prozentualen Verhältnis, das für die
Berechnung angegeben wurde.
Mischungsparameter: einstellbar zwischen 10 % und 50 %
Glykol in der Flüssigkeit.
Durchfluss (Volumen)
- Anzeige des kumulierten Volumens in m3.
Sie können den gespeicherten Wert zurücksetzen, indem Sie
die Tasten (►) und (-) für 5 Sekunden gedrückt halten.
Energie
- Anzeige der kumulierten Energie in kWh.
Sie können den gespeicherten Wert zurücksetzen, indem Sie
die Tasten (►) und (-) für 5 Sekunden gedrückt halten.
Leistung
- Anzeige der momentanen Leistung in W.
2.7 Schutzfunktionen
- Auf diese Zeile gehen, und das Untermenü mit der Taste (►)
öffnen.
 2. Energie -
2. Energie Ja
Durchflusssensor Auto
Sensor warm Auto
Sensor kalt Auto
Flüssigkeit Glycol
Mixed 40%
D-Fluss xxxxm3
Energie 0kWh
Leistung 0.0kW
 Schutzfunktionen -
Max temp Koll. 120°C
Hitzeschutz. Ja
Temp. Berhitzung +10°C
Kühlung. Ja
Max Temp. (xx°C) +40°C
Rückkühlung Ja
Min Temp. (xx°C) -40°C
Frostschutz Ja
Frostschutz Temp -20°C
xxxxm3
Energy 0kWh
Power 0.0kW
30
2.7.1 Max Temp
- Hier lässt sich die Überhitzungsschutzstufe für das
Kollektorfeld einstellen.
(Einstellmöglichkeit von 110°C bis 150°C, Werkseinstellung
120°C)
2.7.2 Hitzeschutz
Diese Funktion stoppt alle Kollektorkreisläufe (P1 und P2),
sobald die Kollektortemperatur über die Höchsttemperatur
über „Max temp“ zuzüglich einer zuvor festgelegten
Temperatur steigt (+10°C Standardwert, kann verändert
werden). Diese Funktion schützt die Anlagenteile
(Leitungen, Armaturen, Gummiringe usw.).
- Um die Funktion zu aktivieren, mit den Tasten (+) oder (-)
auf die Zeile „Hitzeschutz“ gehen, Taste (►) drücken, um
die Option „Ja“ zu wählen und mit den Tasten (+) oder (-)
aktivieren.
- Nun kann der Abstand eingestellt werden
(zwischen +10°C und +30°C, Werkseinstellung ist +10°C).
WICHTIG: Aus Sicherheitsgründen sollte diese Funktion
immer auf Ja“ eingestellt bleiben.
2.7.3 Kühlung
- Wenn die Funktion „Kühlung“ eingeschaltet ist („ja“), kann
auch die Funktion „Rückkühlung“ eingeschaltet werden.
Diese Option dient zum Schutz der Flüssigkeit im Kollektor
und funktioniert wie folgt: Sie schaltet die Solarpumpe P1
oder P2 ein, wenn die Temperatur des Kollektorfeldes T1
oder T4 die vorgegebene Höchsttemperatur „Max Temp
übersteigt, selbst wenn die vorgegebene Höchsttemperatur
des Speichers überschritten ist.
Der Kreislauf stoppt, wenn:
- die Temperatur im Speicher auf 10°C sinkt.
- die Temperatur im Speicher die Kühlstufe "Max Temp"
erreicht (MaxTemp Speicherx + xx°C), der zwischen 5°C
und +40°C einstellbar ist. Der Standardwert beträgt +10°C.
- die Wassertemperatur im Speicher 95°C erreicht.
2.7.4 Rückkühlung
Wenn die Wassertemperatur im Speicher über dem
vorgegebenen Wert "Max Temp Speicher X" liegt, und die
Temperatur des Kollektors um 10°C darunter, schaltet sich
die Pumpe ein, um den Speicher über das Kollektorfeld zu
kühlen (z.B. nachts).
Die Pumpe wird abgestellt, wenn:
- die Wassertemperatur im Speicher auf die Rückkühlstufe
"MinTemp" (MinTemp Speicherx - xx°C) fällt (einstellbar
zwischen -5°C und -40°C, Standardwert -10°C).
- der Abstand zwischen Speicher- und Kollektorfeld-
Temperatur unter 2°C liegt.
2.7.5 Frostschutz
Diese Option hält die Kollektortemperatur T1 oder T4 über
der vorgegebenen Frostschutztemperatur (siehe unten),
indem sie die Pumpen P1 oder P2 einschaltet.
Diese Option kann benutzt werden, um Schneeanhäufung auf
dem Kollektor zu verhindern und die Effektivität tagsüber zu
erhöhen, damit die Solarflüssigkeit nicht beschädigt wird.
Achtung: Es wird empfohlen, diese Funktion in sehr kalten
Regionen nicht zu benutzen, um nicht zu viel gespeicherte
Energie zu verbrauchen.
- Um den Frost- und Schneeschutz zu aktivieren, mit den
Tasten (+) oder (-) auf die Zeile „Hitzeschutz“ gehen, Taste
(►) drücken, um die Option „ja“ zu wählen und mit den Tasten
(+) oder (-) aktivieren.
- Nun lässt sich die Frostschutztemperatur einstellen.
(Einstellmöglichkeit von -20°C bis + 7°C, Werkseinstellung
3°C)
2.8 °C / °F
- Über dieses Menü lassen sich die Anzeigeeinheiten
auswählen.
°F: °F, für Fahrenheit
°C: ° °C, für Celsius
2.9 Röhrenkollektor
Auf die Zeile „Röhrenkollektor“ gehen und mit der Taste (►)
markieren.
- Mit den Tasten (+) oder (-) auf „ja“ gehen, wenn Ihre Anlage
mit Vakuum-Röhrenkollektoren ausgerüstet ist. (Diese Option
kann auch gewählt werden, wenn die Sensoren an den
Außenteilen des Kollektors angebracht sind.)
- Diese Funktion kann benutzt werden, wenn der
Kollektorsensor nicht direkt am Kollektor montiert ist.
Die Funktion arbeitet folgendermaßen:
Alle 30 Minuten schaltet sich die Pumpe für 30 Sekunden ein,
um den genauen Wert des Kollektors zu messen und so
Fehlfunktionen zu vermeiden.
2.10 Werkseinstellungen:
Achtung: Zur Fehlervermeidung werden die gewählten
System- und Zeiteinstellungen nicht zurückgesetzt!
- Zum Rücksetzen der Werte auf die Werkseinstellungen mit
der Taste (►) auf die Zeile „Werkseinstellungen“ gehen. Dann
mit der Taste (+) die Option „ja“ wählen.
- Mehrmaliges Drücken der Taste (◄) führt zurück zum
Hauptmenü.
3 Menü Einstellungen
Dieses Menü enthält sämtliche einstellbaren
Systemparameter.
Manche Systeme unterstützen nicht alle Parameter.
3.1 Maxtemp Speicher1
- Maximaler Wert für die Wassertemperatur in Speicher1
während des normalen Betriebs. (Einstellmöglichkeit von 15°C
bis 95°C, Werkseinstellung 65°C)
3.2 dTOn Speicher1
- Differenz zwischen der Kollektortemperatur T1 und der
Temperatur T2 in Speicher1 zum Start der Hauptpumpe1.
(Einstellmöglichkeit von 4°C bis 40°C, Werkseinstellung 15°C)
3.3 dTOff Speicher1
- Differenz zwischen der Kollektortemperatur T1 und der
Temperatur T2 in Speicher1 zur Ausschaltung der
Hauptpumpe1.
(Einstellbar von 2°C bis 35°C (dTMin <=2°C dTMax
Speicher1), Werkseinstellung 7°C)
Speicher1
T2 (°C)
dTMin
dt Fs
P
1
Kollektor
T1 (°C)
Maxtemp
Speicher1
dtFs
dT = T1
T2
100
%
0%
dtMax
Regelung
dtMax
85%
Aus
100%
Regelung
100%
100%
Aus
31
3.4 dTFs: maximale Drehzahl
- Differenz zwischen Kollektortemperatur T1 und der
Temperatur im Speicher1 T2 um die maximale Drehzahl
(100%) der Pumpe zu erreichen.
(Einstellbar zwischen min. „dtMax Speicher1“ und max. 50°C,
Standardwert 35°C)
3.5 Mindesttemperatur Kollektor
- Dieser Wert legt fest, ab welcher Mindest-Kollektortemperatur
das Solarsystem beladen wird.
(Einstellbar von 0°C bis 99°C (Werkseinstellung 25°C))
Die folgenden Einstellungen sind nur in Systemen mit 2
Speichern (2 und 3) verfügbar.
3.6 Maxtemp Speicher2
- Maximaler Wert für die gewünschte Wassertemperatur in
Speicher2.
(Einstellmöglichkeit von 15°C bis 95°C, Werkseinstellung
65°C)
3.7 dTOn Speicher2
- Differenz zwischen der Kollektortemperatur T1 und der
Temperatur T4 in Speicher2 zum Start der Hauptpumpe1 mit
System2 oder Pumpe2 mit System3.
(Einstellmöglichkeit von 3°C bis 40°C, Werkseinstellung 15°C)
3.8 dTOff Speicher
- Differenz zwischen der Kollektortemperatur T1 und der
Temperatur T4 in Speicher2 zur Ausschaltung der
Hauptpumpe1 mit System2 oder Pumpe2 mit System3.
(Einstellbar von 2°C bis 35°C (dTMin <=2°C dTMax
Speicher2), Werkseinstellung 7°C)
Bemerkung:
Bei Systemen mit 2 Speichern kann der Vorrangspeicher im
Menü „Service“, im Untermenü „Prio Sp.“ ausgewählt werden.
Hier können auch die Zeiten des Ladezyklus für den
Nachrangspeicher im Untermenü „Prio. Zeit Laden“ und „Prio.
Zeit Pause.“ eingestellt werden.
__________________________________________________
Die folgenden Einstellungen sind nur in System 6 verfügbar.
3.9 dTOn rücklauf
Steht nur für System 6 zur Verfügung.
-Differenz zwischen der Temperatur in Speicher1 T2 und
externem Heizungsrücklauf T4 zum Vorwärmen des
Heizungsrücklaufs über Speicher1. (Einstellbar von 3°C bis
40°C (Werkseinstellung 15°C))
3.10 dTOff rücklauf
Steht nur für System 6 zur Verfügung.
-Differenz zwischen der Temperatur in Speicher1 T2 und
Heizungsrücklauf T4 zum Abschalten der Vorwärmung im
externen Heizkreis.
(Einstellmöglichkeit von 2°C (dTMax rücklauf -2°C),
Werkseinstellung 7°C)
ZUSATZFUNKTIONEN
Die Einstellungen für "Extra" werden nur dann verfügbar, wenn
eine "Extra"-Funktion für einen Ausgang im Menü für die
Konfiguration der Ausgänge ausgewählt wurde.
3.11 Thermostatfunktion
Nur verfügbar, wenn im Untermenü „Extra“ die
Zusatzfunktion „Thermostat“ ausgewählt wurde.
3.11.1 Start
- Dieser Wert legt fest, ab welcher Wassertemperatur (T3)
oben im Speicher die Zusatzheizung (P3) gestartet wird.
(Einstellmöglichkeit von 20°C bis 90°C, Werkseinstellung
55°C)
3.11.2 Hysterese
- Dieser Wert legt fest, dass die Zusatzheizung (P3)
abgeschaltet wird, sobald die Wassertemperatur oben im
Speicher (T3) mehr als die Temperatur beim Start plus
Hysteresewert beträgt. (Einstellmöglichkeit von 2°C bis
30°C, Werkseinstellung 10°C)
Die folgenden Zeitparameter sind für die folgenden Extra-
Funktionen "Thermostat", "Kühlung" und "Differenzregelung"
verfügbar:
3.11.3 Verzögerung
- Zeitverzögerung beim Start des Ausgangs (P3).
Wenn das Relais P3 auf den Minuswert "-xxxs" eingestellt
wird, startet das Relais "xxx Sekunden" vor dem
Einschalten.
Wenn das Relais P3 auf den Pluswert "+xxxs" eingestellt
wird, startet das Relais "xxx Sekunden" nach dem
Einschalten.
(Einstellmöglichkeit von -900 s bis +900 s, Standardwert "0")
3.11.4 Legionellenschutz
- Anzahl der Tage für die Aktivierung des
Legionellenschutzes. Diese Funktion wird normalerweise
verwendet, wenn der Speicher mit Brauchwasser gefüllt ist
und der Speicher mit dem zusätzlichen Ausgang (P3) auf
65°C (T3) erhitzt wird und wenn das Wasser im Speicher
diese Temperatur in den vorher eingestellten Tagen nicht
erreicht hat. (Einstellung zwischen 1 und 7 Tagen,
Werkseinstellung: 1 Tag)
3.11.5 Timer
- Der Timer-Block wird verwendet, um ein Tagesprogramm
zu erstellen, mit dem die Betriebszeit des zusätzlichen
Ausgangs (P3) initialisiert wird. Diese Funktion wird
normalerweise verwendet, um Energie einzusparen, falls
eine zusätzliche Wärmequelle zum Heizen des Speichers
verwendet wird (z.B. wenn die zusätzliche Wärmequelle nur
am Abend zur Verfügung steht und das Laden mit
Sonnenenergie am Tag unzureichend war).
Verwenden Sie die Timer-Funktion, indem Sie die Zeile
"Timer" und dann "Ja" auswählen. Sie können anschließend
die Zeiten für "Start" und "Stop" für drei Blöcke einstellen.
Temperatur T3 (°C) des Wassers oben im Speicher1
Start T3
Start T3 +
Hysterese
Extra P3
32
3.12 Kühlfunktion
Nur verfügbar, wenn im Untermenü „Extra“ die
Zusatzfunktion „Kühlung“ ausgewählt wurde.
3.12.1 Einschaltung der Kühlung
- Wert, ab dem die Wärme aus Speicher1 (durch
Einschalten des Ausgangs P3) in einen anderen
Wärmespeicher abgeleitet wird, z.B. wenn die
Wassertemperatur oben im Speicher1 (T3) über diesem
Wert liegt. (Einstellmöglichkeit von 20°C bis 90°C,
Werkseinstellung 75°C)
3.12.2 Kühlhysterese
- Dieser Wert legt fest, dass die Kühlung von Speicher1
abgeschaltet wird, sobald die Wassertemperatur im oberen
Speicherteil (T3) weniger als die Temperatur bei Kühlung
anschalten minus Hysteresewert beträgt. (Einstellmöglichkeit
von 1°C bis 30°C, Werkseinstellung 10°C)
3.13 Differenzregelung
Nur verfügbar, wenn im Untermenü „Extra“ die Zusatzfunktion
diff. regler“ ausgewählt wurde.
3.13.1 Max Kalt Speicher
- Höchsttemperatur im Speicher1 zur Ausschaltung der
Wärmeübertragung (T3 = TC).
(Einstellmöglichkeit von 15°C bis 95°C, Werkseinstellung
65°C)
3.13.2 Min Warm Speicher
- Mindesttemperatur des externen Speichers zur Einschaltung
der Wärmeübertragung (T4 = TW). (Einstellmöglichkeit von
0°C bis 95°C, Werkseinstellung 15°C)
3.13.3 dT On
- Differenz zwischen der Kälte- und Wärmespeicherung zur
Einschaltung des Wärmeaustausches. (Einstellmöglichkeit von
3°C bis 40°C, Werkseinstellung 15°C)
3.13.4 dT Off
- Differenz zwischen der Kälte- und Wärmespeicherung zur
Abschaltung des Wärmeaustausches. (Einstellmöglichkeit von
2°C bis 30°C, Werkseinstellung 7°C)
3.14 Funktion Antistagnation
Nur verfügbar, wenn die Zusatzfunktion „Antistagnation“ im
Untermenü „Extra“ gewählt wird.
3.14.1 Einschaltebene
- Ebene auf Kollektor (T1) einstellen, um die Funktion zu
starten. Die Pumpe P1 wird eingeschaltet, um die Wärme des
Kollektors über die Pumpe P3 abzuführen (Einstellmöglichkeit
von 0°C bis 200°C, Werkseinstellung 110°C)
3.14.2 Abschaltebene
- Ebene auf Kollektor (T1) einstellen, um die Funktion
Antistagnation zu stoppen. Die Pumpen P1 und P3 werden
ausgeschaltet. (Einstellmöglichkeit von 0°C bis 150°C,
Werkseinstellung 90°C)
 Einstellungen -
Verz. +900s
Timer On
Zeit 1 Start 24H00
Zeit 1 Stop 24H00
Zeit 2 Start 24H00
Zeit 2 Stop 24H00
Zeit 3 Start 24H00
Zeit 3 Stop 24H00
Temperatur T3C) des Wassers oben im
Speicher1
Abschaltung der
Kühlung
(Start Hysterese)
Einschaltung
der Kühlung
P3
Kollektor
(T1°C)
Abschalteben
e
Einschaltebe
ne
P1
Speicher
(T2°C)
P3
Standard-
Ladezyklus
Antistagnation
s-Zyklus
Wärmespeicherung TW
Kältespeicherung TC
Min Warm
Speicher
Max Kalt
Speicher
Extra P3
dTMin
dTMax
33
4 Menü Betrieb
4.1 Automatikbetrieb und Ausgeschaltet
- Um das System in den Automatikbetrieb zu schalten, mit den
Tasten (+) und (-) auf „Automatik“ gehen und diesen
Betriebsmodus mit der Taste (►) aktivieren.
- Um das System auf die Betriebsart „Aus“ zu schalten,
Schritte wiederholen.
Bemerkung: Der Reglerstatus wird über eine kleine Grafik im
Hauptmenü mit "Aus" angezeigt.
4.2 Funktion Schornsteinfeger
WARNUNG VERWENDUNG AUF EIGENE GEFAHR:
Die Heizung ist auf Maximaltemperatur eingestellt, um ein
Überhitzen des Brenners zu verhindern. Einige Heizrohre
können bei Temperaturen von über 40°C beschädigt
werden!
Die Funktion „Schornsteinfeger“ wird verwendet für:
Rauchgasmessungen am Heizsystem
Vollastläufe des Heizsystems
(Verbrennen möglicher Rückstände im Brenner, wenn
dieser lange unter Teillast gelaufen ist)
Sicherheitsregeln für die Verwendung der Funktion
Schornsteinfeger“:
1. „Die Funktion „Schornsteinfeger“ wird nur für die Dauer
des Bedarfs aktiviert.
Während der Funktion „Schornsteinfeger“ werden die
Ausgänge:
P3 (mit MULTIPLEX P4, P5, P7, P9, P10) eingeschaltet
P1, P2 (mit MULTIPLEX P6, P8) ausgeschaltet
WARNUNG: System nicht Überhitzen!
2. Wenn die Funktion „Schornsteinfeger“ abgeschlossen
ist, den LCD+ Solarregler für einige Sekunden
ausschalten.
Aus (aktiv)
3. Bevor Sie den LCD+ Solarregler wieder einschalten,
prüfen Sie alle Elemente (Rohre usw.) der Installation, um
sicherzustellen, dass keine Schäden aufgetreten sind.
Automatisch (aktiv)
4.3 Test manuell
- Dieser Modus erlaubt die Kontrolle der Funktion von Pumpe1,
Pumpe2 / Ventil und der Zusatzausgänge sowie der Werte
sämtlicher Sensoreingänge.
(Hinweis: für unbenutzte Sensoreingänge wird der Höchstwert
angezeigt)
- Zum Aktivieren des gewählten Ausgangs mit den Tasten (+)
und (-) auf die entsprechende Zeile gehen und diese mit der
Taste (►) markieren. Mit den Tasten (+) und (-) lassen sich
nun die verschiedenen Ausgänge aktivieren.
- Die Pumpen mit dem im Menü „Einstellungen
vorgegebenen Mindestwert xx % starten (s. nachfolgenden
Abschnitt Pumpendrehzahl). Der Mindestwert lässt sich mit
der Taste (+) in Schritten von 5 % bis auf 100 % erhöhen.
- Hinweise: Beim Verlassen des Menüs sind sämtliche
Ausgänge ausgeschaltet.
- Mehrmaliges Drücken der Taste (◄) führt zurück zum
Hauptmenü.
5 Menü Betriebsstunden
Über dieses Menü lassen sich die Diagramme für
Betriebsstunden, dT, Leistung und Energie anzeigen, die vom
Regler aufgezeichnet wurden.
Zur Anzeige der vollständigen Skala den Cursor mit der Taste
(+) oder (-) bewegen (48H).
Der Regler kann alle Speicherdaten und Installationsparameter
auf einer SD-Karte aufzeichnen und speichern. Mit ihrer Hilfe
kann die Leistung der verwendeten Solaranlage analysiert und
die Anlage auf einem PC konfiguriert werden (für diese
Funktion ist ein spezielles Watts-Datenlog-Kit mit Software
erforderlich. Watts-Bestell- Nr. P04189).
Nach Einlegen der SD-Karte muss diese aktiviert werden:
Mit den Tasten (+) und (-) auf die Zeile „SD-Karte“ gehen und
diese mit der Taste (►) markieren. Mit den Tasten (+) und (-)
lässt sich die SD-Karte aktivieren.
SD-Karte Deaktivieren => die SD-Karte ist
betriebsbereit
SD-Karte Aktivieren => die SD-Karte ist ausgeschaltet
oder deaktiviert
Hinweise:
- Die Daten werden nur gespeichert, wenn die SD Karte im
Regler eingesteckt und aktiviert ist. (Alle Daten, die im
Solarregler bereits registriert wurden, werden daher nicht im
Computer gespeichert)
- Nach Einschub und Aktivierung der SD-Karte erscheint ein
kleines SD-Kartensymbol auf dem Hauptbildschirm.
- Wichtig: Die SD Karte nicht vor dem Deaktivieren
herausziehen.
 Betrieb----------------- -- ----
Automatik (aktiv)
Aus
Schornsteinfeger
Test manuell
 Betrieb----------------- -- -----
P1 0%
P2 0%
P3 0%
T1 _ _ °C T2 _ _°C T3 _ _ °C
T4 _ _°C T5 _ _ °C
GT _ °C F _ _ L/min P _ _ Bar
 Betriebsstunden-------- -- ---
Betrieb _ _ h
dT _ _°C
Leistung _ _kW
Energie _ _kWh
SD-Karte
deaktivieren
Betrieb 0,0h
-
+
0t 00h
34
Datenlog-Kit mit Watts-Software und SD-Karte
Die Solarsteuerung kann alle Anlagenparameter und
Betriebsdaten auf einer SD-Karte speichern. Mit ihrer Hilfe
kann das System und die Leistung der verwendeten
Solaranlage analysiert und die Anlage auf einem PC
konfiguriert werden. Erforderlich ist ein spezielles Datenlog-Kit
(Speicherkartenset mit Software, Bestell-Nr. P04189)
a) Anlagenparameter und Systeme
(Schemen, Zusatzfunktionen, Drehzahlregelung,
Speichervorrang, Durchflusssensor usw.)
- Anlagenparameter am PC einstellen und auf die
Solarsteuerung übertragen
- Auf der SD-Karte gespeicherte Anlagenparameter am
PC überprüfen
Erforderliche Hard- und Software: SD-Speicherkartenset
- Aktuelle Anlagenparameter von der Solarsteuerung auf
eine SD-Karte speichern
Erforderliche Hard- und Software: SD-Karten Set; SD-Karte
Max. 2GB (FAT32), nein SDHC
b) Betriebsdaten, Anlagenüberwachung und
Energiebilanzierung
(Betriebsdaten wie Energieertrag, Betriebsstunden,
Sensortemperaturen, Pumpendrehzahl und Schaltzyklen,
Durchfluss usw.)
- Betriebsdaten dauerhaft auf einer SD-Karte aufzeichnen
Erforderliche Hard- und Software: SD-Speicherkartenset
- Auswertung der Betriebsdaten, Anlagenüberwachung
und Energiebilanzierung am PC
Erforderliche Hard- und Software: SD-Speicherkartenset
Hinweise:
Für folgende Funktionen ist das Watts-Datenlog-Kit mit
Software erforderlich (Bestell-Nr. P04189):
- Anlagenparameter am PC einstellen und auf die
Solarsteuerung übertragen
- Auf der SD-Karte gespeicherte Anlagenparameter am PC
überprüfen
- Auswertung der Betriebsdaten, Anlagenüberwachung und
Energiebilanzierung am PC
Für folgende Funktionen ist kein Watts-Datenlog-Kit mit
Software erforderlich:
(Für diese Funktion ist nur eine leere SD-Karte erforderlich,
die nicht im Lieferumfang der Solarsteuerung enthalten ist)
- Betriebsdaten dauerhaft auf einer SD-Karte aufzeichnen
- Aktuelle Betriebsdaten des Reglers auf einer SD-Karte
aufzeichnen
6 Menü Temperaturen
- Über dieses Menü lassen sich die momentanen Werte
sämtlicher angeschlossener Sensoren aufrufen.
- Mit den Tasten (+) und (-) einen Sensor wählen und mit
der Taste (►) das Zeitdiagramm öffnen.
- Zur Anzeige der vollständigen Skala den Cursor mit der
Taste (+) oder (-) bewegen (60min). Wird das Ende des
ersten Fensters erreicht, ändert sich die Kurve und zeigt
die nächsten 100 Punkte an.
7 Spezialfunktionen
7.1 Festsitzschutz der Pumpe
Wenn die Pumpen 48 Stunden nicht gearbeitet haben,
werden sie für 15 Sekunden eingeschaltet, damit sie nicht
blockieren.
7.2 Dimmerfunktion
Um weniger Strom zu verbrauchen, wird die
Hintergrundbeleuchtung reduziert, wenn 15 Minuten lang
keine Taste gedrückt wird.
7.3 Sicherheitsfunktion
Um Veränderungen nach der Installation zu verhindern, kann
auf die Installationsparameter (System- und Zusatzfunktionen)
4 Stunden nach dem Einschalten nicht mehr zugegriffen
werden. Vor dem Ändern dieser Parameter muss der
Solarregler vom Netz genommen und wieder angeschlossen
werden. Dabei werden keine Einstellungen gelöscht.
Alle anderen Parameter können auch nach 4 Stunden noch
geändert werden, damit das System optimiert werden kann.
8 Sonstiges
Entsprechender Wert für Sensor PT1000:
(Mit einem Ohmmeter überprüfen, nur bei abgeschaltetem
Sensor)
-10°C / -14°F 960 Ohm
0°C / 32°F 1000 Ohm
10°C / 50°F 1039 Ohm
20°C / 68°F 1077 Ohm
30°C / 86°F 1116 Ohm
40°C / 104°F 1155 Ohm
50°C / 122°F 1194 Ohm
60°C / 140°F 1232 Ohm
70°C / 158°F 1271 Ohm
80°C / 176°F 1309 Ohm
90°C / 194°F 1347 Ohm
100°C / 212°F 1385 Ohm
120°C / 248°F 1461 Ohm
140°C / 284°F 1535 Ohm
Hinweis:
Erweiterungsmodul MULTIPLEX
Bei Bedarf kann der LCD+ Regler mit dem MULTIPLEX Regler
erweitert werden, um komplexere Systeme sowie
Heizkreisregelungen zu realisieren.
 Temperaturen --- --
T1 xxx°C
T2
xxx°C
T3
xxx°C
T4
xxx°C
T5
xxx°C
Kollektor1 _ _°C
- +
82
50
18
35
9 Notizen
36
PPLIMW06651Fa Rev :25/09/2015
29

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Watts Solar Controller LCD PLUS bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Watts Solar Controller LCD PLUS in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 1.12 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info