39
Resistance range, overload protection 250V
Range Accuracy Note
x1 / x10 / x1k / x10k / x100k ± 3%
Frequency range, overload protection 500 V
Range Accuracy Note
250 Hz / 2.5 kHz / 25 kHz ± 3% Sensitivity 2.5 V
max. 10 V
Transistor test
Range Accuracy Note
hFE 0 - 1000 not specified Test in the Ohm x10 range
Testing current approx. 10 µA
Testing voltage max. 3.2 Vce
Diode test
Range Accuracy Note
IF / IR / LI / LV not specified
Testing current max. 1.5 µA in the x100k range
15 µA in the x10k range
0.15 mA in the x1k range
15 mA in the x10 range
150 mA in the x1 range
Acoustic continuity checker, overload protection 250 V
Note
Measuring range <200 Ω
ƽ
Do not exceed the permitted max. input values. Never touch circuits or parts of
circuits with a possible voltage of more than 25 V/ACrms or 35 V/DC! Danger to life!