Specifications and measurement tolerances
Specifications
Over-voltage category CAT III 500V to ground potential
Max. measuring voltage 500 V
Analogue display with mirror scale
Input resistance V range approx. 10MΩ
Power supply 9V (PP3) + 2x AA
Operating temperature 0°C to +40°C
Storage temperature -10°C to +50°C
Operating altitude max. 2,000 m
Relative humidity < 75%, non-condensing
Temp. for guaranteed accuracy +18°C to +28°C
Weight approx. 360 g
Dimensions (LxWxH) 160 x 104 x 44 (mm)
Measurement tolerances
Accuracy information in ± (% of the scale value). The accuracy is valid for one year at a temperature of
+23°C ± 5°C, and at a relative humidity of less than 75 %, non-condensing.
Constant voltage range, overload protection 500 V (range 0.05 V, max. 250 V)
Range Accuracy Note
0.05 V ± 4% Internal resistance 10MΩ
2.5 V / 10 V / 50 V / 250 V / 500 V ± 3%
AC voltage range (40Hz - 400Hz), overload protection 500 V
Range Accuracy Note
10 V / 50 V / 250 V / 500 V ± 4% Internal resistance 10MΩ
Direct current range
Range Accuracy Note
± 3%
25 µA / 2.5 mA / 25 mA / 250 mA ± 3% Voltage drop ≤ 250mV
F 0.5A /500V
10 A ± 4% not secured
max. 10 s with 15 min pause