OPERATING INSTRUCTIONS
www.voltcraft.de
Infrared Thermometer IR-380
Version 09/07
Item no. 10 09 06
Intended use
The device serves for non-contact temperature measurement. It determines the temperature by the amount of
infrared energy emitted by the object and its emissivity. It is especially useful for temperature measurement of
hot, hard to reach or moving targets.
The thermometer measures the surface temperature of an object. It cannot measure through transparent
surfaces such as glass and plastic. Its temperature measuring range is from -50ºC to 800ºC. It is powered by
a 9V block battery.
This product ful ls European and national requirements related to electromagnetic compatibility (EMC).
CE conformity has been veri ed and the relevant statements and documents have been deposited at
the manufacturer.
Any usage other than described above is not permitted and can damage the product and lead to associated
risks such as short-circuit, re, electric shock, etc. Please read the operating instructions thoroughly and keep
them for further reference.
Features
Dual laser targeting
Capture maximum temperature during measurement
Integrated high and low temperature alarms
Adjustable emissivity, from 0.10 to 0.99
Background illumination for operation in poorly lit area
Delivery contents
Infrared thermometer IR-380
Carrying bag
9V block battery
Operating instructions
Safety instructions
We do not assume liability for resulting damages to property or personal injury if the
product has been abused in any way or damaged by improper use or failure to observe
these operating instructions. The warranty will then expire!
An exclamation mark in a triangle indicates important information in the operating
instructions. Carefully read the whole operating instructions before operating the device,
otherwise there is risk of danger.
Unauthorised conversion and/or modi cation of the product are inadmissible because of safety and
approval reasons (CE).
The product must not be subjected to heavy mechanical stress or intense vibration.
The product must not be exposed to electromagnetic elds, extreme temperatures, direct sunlight or
dampness.
The device must not be exposed to humidity or liquids. It must be used under appropriate weather conditions
only or with appropriate protection in case of outdoor use.
Steam, dust, smoke and/or vapours can prevent accurate measurement by obstructing the thermometer’s
optics.
Laser beam must not be stared into or viewed directly with optical instruments.
Laser beam must not be pointed on mirrors or other re ecting areas.
Laser beam must not be directed at other people or animals or into public areas. Laser radiation may lead
to eye or skin injuries.
This product is equipped with a class 2 laser according to EN 60825-1:1994+A1:2002+ A2:2001.
LASER RADIATION-DO NOT
STARE INTO THE BEAM
CAUTION
CLASS 2 LASER PRODUCT
WAVELENGTH: 630-670nm OUTPUT:<1mW
EN 60825-1:1994 + A1: 2002 + A2: 2001
Caution: Operating the product or alternating its setting others than described herein could lead to
hazardous radiation exposure.
The product should not be connected immediately after it has been brought from an area of cold
temperature to an area of warm temperature. Condensed water might destroy the product. Wait until the
product stabilises to adapt to the new ambient temperature before use.
If there is reason to believe that safe operation is no longer possible, put the device out of operation and
secure it against unintended operation. Safe operation is no longer possible if:
the product shows visible damages,
the product no longer works and
the product was stored under unfavourable conditions for a long period of time,
the product was subject to considerable transport stress.
The product is not a toy and should be kept out of reach of children and pets!
On commercial premises, the accident prevention regulations of the Association of Industrial Professional
Associations with respect to electrical systems and operating equipment must be observed.
In schools, training centres, Hobby and DIY workshops, the handling of measuring appliances must be
responsibly supervised by trained personnel.
Servicing, adjustment or repair works must only be carried out by a specialist/ specialist workshop.
If you have queries about handling the measuring device, that are not answered in this operating instruction,
our technical support is available under the following address and telephone number:
Voltcraft
®
, 92242 Hirschau, Lindenweg 15, phone 0180 / 586 582 723 8
-
-
-
-
Operating elements
1
2
3
4
5
6
7
8
9
10
1 Display 6 Trigger
2“
” button 7 ºC/ ºF slide switch
3 ” button 8 Battery terminal
4 “MODE” button 9 Infrared sensor opening
5 Battery compartment 10 Laser apertures
Display
ABCDEFG
HJLIK
A “SCAN”, measurement indicator
B “HOLD”, Data hold indicator
C Laser symbol
D Lock indicator
E High alarm indicator
F Low alarm indicator
G Measuring unit (ºC/ ºF)
H Low battery symbol
I Emissivity
J Emissivity symbol
K Maximum temperature
L Measured temperature
Battery installation
Observe correct polarity while inserting the batteries. Remove the batteries if the device is
not used for a long period of time to avoid damage through leaking. Leaking or damaged
batteries might cause acid burns when contact with skin, therefore use suitable protective
gloves to handle corrupted batteries.
Keep batteries out of reach of children. Do not leave the battery lying around, as there is
risk, which children or pets could swallow it.
Make sure that batteries are not dismantled, short-circuited or thrown into re. Never
recharge non-rechargeable batteries. There is a risk of explosion!
Replace the battery when the low battery symbol,
, appears.
Open the battery compartment (5).
Insert one 9V block battery to the battery terminal (8). The 9V block battery is designed to be connected in
one orientation only to avoid wrong polarity. Do not insert the battery by force.
Close the battery compartment (5).
Operation
Point the opening (9) of the thermometer towards the target. For accurate temperature measurement aim
the thermometer perpendicular to the target.
To measure the temperature of a stationary or xed surface, aim the sensor at the starting point and
move it across the surface.
To take a temperature scan of a moving surface, aim the sensor at a xed point and measure the
temperature as the target moves past, or continually scan across the target as it moves past.
Hold the trigger (6) to initiate the measurement. “SCAN” appears on the display (1).
The measured temperature will be shown on the display (1).
Upon releasing the trigger (6), the measured value will be held for 7 seconds. “HOLD” appears on the
display (1).
The thermometer is switched off after 7 seconds unless the thermometer is locked.
To locate the hot or cold spot
Aim the thermometer outside the target.
Scan across the target with up and down motion.
The thermometer is not recommended for use in measuring re ective surfaces such as stainless
steel and/or aluminium wrapping. The temperature of a re ective object may be measured if the
surface is coated with a matt material.
The thermometer needs to adjust to the ambient temperature in order to produce correct
readings.
1.
2.
3.
1.
-
-
2.
3.
4.
1.
2.
Distance to spot ratio (D/S)
The target should be larger than the thermometer’s measurement spot size to achieve precise measurement.
The temperature recorded is the average temperature of the spot.
The smaller the target is, the shorter the distance is between the thermometer and the target.
ø13, 260
20D
=
1S
ø25, 500
ø38, 760
Spot size (mm)
Legend
Laser
Infrared
Measuring Distance (mm)
Dual targeting lasers
For determining the measuring area easily, dual targeting lasers for aiming are integrated. The two laser spots
converge to a single spot when at a distance of 260 mm from the target. From then onward, they indicate the
true diameter of the measurement spot.
For precise measurement, it is recommended to keep the measuring distance at 260 mm whenever possible.
Press the “
” button (2) to activate/ deactivate the dual targeting lasers. The “ ” symbol appears on the
display to indicate that the targeting laser is activated.
The lasers are turned on when the trigger is pulled and turned off when the trigger is released.
Measuring unit adjustment (ºC/ ºF)
Locate the “ºC/ ºF” slide switch (7) inside the battery compartment.
Set the switch position to “ºC” or “ºF” to set the measuring unit.
Backlight
Press “ ” button (3) to activate the display backlight when measuring in dark environment.
Field veri cation of accuracy
The thermometer is calibrated, but its accuracy can be veri ed in the eld by using the following procedure.
Prepare an aluminium container such as beverage can.
Paint the container with matt black spray paint or apply matt black adhesive material to the outer surface.
Fill the aluminium container with refrigerated water, insert a standard thermometer and allow the can and
standard thermometer to come to equilibrium.
Take a reading with the thermometer. Do not exceed the spot size of the IR thermometer.
Compare the temperature reading of the IR thermometer with the standard thermometer.
Repeat this procedure using hot water.
Con guration
LAL
setting
LAL
on/off
HAL
setting
HAL
on/off
LOCKEMS
Press the “MODE” button (4) to advance through the selection sequence as shown in above diagram.
Press the “
” button (2) or “ ” button (3) to adjust the value of the selected setting.
Press the trigger to save the adjustment and exit the con guration mode.
Emissivity (EMS) adjustment
The emissivity depends on the material and its surface characteristics. Most organic materials or oxidized
surfaces have an emissivity of approx. 0.95, which is the default value of this thermometer. However, metallic
surfaces or shiny objects have a lower emissivity. To compensate this, the thermometer integrates an emissivity
adjustment function for accurate measurement.
Press the “MODE” button (4) until the “
=” symbol ashes to select emissivity adjustment.
Press the “
” button (2) or “ ” button (3) to adjust the emissivity, from 0.10 to 0.99. For reference emissivity
value, please refer to “Surface emissivity” table in the “Technical data”.
Pull the trigger to save the adjustment and exit the con guration mode or press the “MODE” button (4) to
advance to the next setting.
Lock on/off (LOCK)
The lock feature sets the thermometer to continuous measurement.
Press the “MODE” button (4) until the “
” symbol ashes to select lock function.
Press the “
” button (2) or “ ” button (3) to turn on/off the lock function. (“ON” = on; “OFF” = off)
Pull the trigger to save the adjustment and exit the con guration mode or press the “MODE” button (4) to
advance to the next setting.
When the lock is on, the “
” symbol appears. The thermometer will measure continuously without the
trigger being held.
Pull the trigger to turn off the lock function.
High Alarm (HAL)
Press the “MODE” button (4) until the “ ” symbol ashes to select the high alarm function.
Press the “
” button (2) or “ ” button (3) to turn on/off the high alarm function. (“ON” = on; “OFF” = off)
Press the “MODE” button (4) to proceed to set the alarm value.
Press the “ ” button (2) to increase or “
” button (3) to decrease the alarm value within the range of
-50.0ºC to 800.0ºC.
Pull the trigger to save the adjustment and exit the con guration mode or “MODE” button (4) to advance
to the next setting.
The “
” symbol appears to indicate that the high alarm is activated.
An audible alarm will be generated if the measured value is above the temperature set in the high alarm
(HAL).
Low Alarm (LAL)
Press the “MODE” button (4) until the “ ” symbol ashes to select the low alarm function.
Press the “
” button (2) or “ ” button (3) to turn on/off the low alarm function. (“ON” = on; “OFF” = off)
Press the “MODE” button (4) to proceed to set the alarm value.
Press the “ ” button (2) to increase or “
” button (3) to decrease the alarm value within the range of
-50.0ºC to 800.0ºC.
Pull the trigger to save the adjustment and exit the con guration mode or “MODE” button (4) to advance
to the next setting.
The “
” symbol appears to indicate that the low alarm is activated.
An audible alarm will be generated if the measured value is below the temperature set in the high alarm
(LAL).
1.
2.
3.
4.
5.
6.
1.
2.
3.
1.
2.
3.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
6.
Maintenance
Lens Cleaning:
Blow off loose particles using clean compressed air and then brush the remaining debris away with a ne
lens brush.
Wipe the surface with a lens cleaning cloth or a clean, soft, lint-free cloth. In the case of ngerprints or any other
grease formation, the cloth may be moistened with water or lens cleaning uid.
Do not use acid, alcohol, or other solvents or harsh, linty cloth to clean the lens. Avoid excessive cleaning and
excessive pressure.
Cleaning the exterior:
To clean the exterior housing, use soap and water or a mild commercial cleaner. Do not use abrasive or
solvents!
Disposal
Dispose of waste electrical and electronic equipment
In order to preserve, protect and improve the quality of environment, protect human health and
utilise natural resources prudently and rationally, the user should return unserviceable product to
relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately and not as
municipal waste.
Used batteries/ rechargeable batteries disposal
The user is legally obliged (battery regulation) to return used batteries and rechargeable batteries.
Disposing used batteries in the household waste is prohibited! Batteries/ rechargeable
batteries containing hazardous substances are marked with the crossed-out wheeled bin. The
symbol indicates that the product is forbidden to be disposed via the domestic refuse. The
chemical symbols for the respective hazardous substances are Cd = Cadmium, Hg = Mercury,
Pb = Lead.
You can return used batteries/ rechargeable batteries free of charge to any collecting point of your
local authority, our stores or where batteries/ rechargeable batteries are sold.
Consequently you comply with your legal obligations and contribute to environmental protection!
Technical data
Operating Voltage: 9V
Current consumption: max. 5.5mA
Measuring temperature range: -50ºC to 800ºC (-58ºF to 1472ºF)
Resolution: 0.1ºC (0.1ºF)
Accuracy: ± 2.5ºC (4.5ºF) -50ºC to 20ºC (-58ºF to 68ºF)
± 1.0% ± 1.0 ºC (1.8ºF) 20ºC to 300ºC (68ºF to 572ºF)
± 1.5% 300ºC to 800ºC (572ºF to 1472ºF)
Repeatability: ± 1.3ºC (2.3ºF) -50ºC to 20ºC (-58ºF to 68ºF)
± 0.5% or ± 0.5ºC (0.9ºF) 20ºC to 800ºC (68ºF to 1472ºF)
Response time: 150ms
Spectral response: 8 to 14 μm
Distance-to-Spot ratio: 20:1
Laser wavelength: 630 - 670 nm
Laser emission power: <1mW
Operating temperature: 0ºC to 50ºC
Operating humidity: 10% to 90% relative humidity, non-condensing
Storage temperature: -10ºC to 60ºC
Storage humidity: <80% relative humidity, non-condensing
Weight: 163 g
Dimensions (L x W x H): 146 x 104 x 43 mm
Surface emissivity
Measured surface Emissivity Measured surface Emissivity
Asphalt 0.90 to 0.98 Lacquer 0.80 to 0.95
Brick 0.93 to 0.96 Lacquer (matt) 0.97
Cement 0.96 Lather 0.75 to 0.80
Ceramic 0.90 to 0.94 Marble 0.94
Charcoal (powder) 0.96 Mortar 0.89 to 0.91
Chromium oxides 0.81 Paper 0.70 to 0.94
Cloth (black) 0.98 Plaster 0.80 to 0.90
Concrete 0.94 Plastic 0.85 to 0.95
Copper oxides 0.78 Rubber (black) 0.94
Glass 0.90 to 0.95 Sand 0.90
Human skin 0.98 Soil 0.92 to 0.96
Ice 0.96 to 0.98 Textiles 0.90
Iron oxide 0.78 to 0.82 Water 0.92 to 0.96
The emissivity values shown in the above table are approximate. Several parameters, e.g.
geometry, surface quality, may affect the emissivity of an object.
These operating instructions are published by Voltcraft
®
, Lindenweg 15,
D-92242 Hirschau/ Germany, Phone +49 180 586 582 723 8.
The operating instructions re ect the current technical speci cations at time of print.
We reserve the right to change the technical or physical speci cations.
© Copyright 2007 by Voltcraft
®
.
*02_09/07_02-RC
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Voltcraft IR-380 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Voltcraft IR-380 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 0,23 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info