785222
8
Verklein
Vergroot
Pagina terug
1/40
Pagina verder
When the Lynx Smart BMS is switched off the following happens:
The ATC (allowed to charge) and ATD (allowed to discharge) signals are turned off, so that all loads and chargers are turned
off.
When the battery current is low enough the contactor will open so that the DC system is disconnected from the batteries.
The AUX terminal will de-power so that a connected GX device will also de-power.
The Lynx Smart BMS goes into hibernation mode.
Bluetooth will remain active.
There are 3 ways to operate the remote on/off feature:
Wire a switch between the remote-H and the remote-L terminal. When the switch is open the Lynx Smart BMS is off and will be
on when the switch is closed.
Present a High signal to the H terminal. If the H terminal is High (more than 2V) the Lynx Smart BMS switches on, and if the H
terminal is Low (less than 2V) the Lynx Smart BMS will switch off.
Present a Low signal to the L terminal. If the L terminal is pulled to ground the Lynx Smart BMS switches on, and if the L
terminal is free floating the Lynx Smart BMS will switch off.
3.4. Pre-charge circuit
The Lynx Smart BMS is equipped with a pre-charge circuit. This will pre charge capacitive loads such as inverters or inverter/
chargers before the contactor closes.
During pre-charge checks are performed. If the connected load is less than 20 Ohm, the current is too large or pre-charging takes
too long, the contactor will not close and an error will be generated.
If a pre-charge error has occurred, the Lynx Smart BMS will, after a wait time of 30 seconds, again try to perform a pre-charge. It
wil try this up to a maximum of 20 times.
3.5. Fans
The Lynx Smart BMS has two built-in fans. These turn on shortly during startup, when the loads are pre-charged.
In normal operation the fans will also turn on when:
The temperature exceeds 60°C (140°F).
The current exceeds 320A.
The dissipation in the contactor is too high (to prevent contactor overheating).
3.6. Battery Management System
Pre-alarm
The Lithium Smart battery sends a pre-alarm signal to the Lynx Smart BMS when one of its cell voltages drops below a set
threshold. The pre-alarm voltage threshold is set in the battery via the VictronConnect app. All batteries need to be set at the
same pre-alarm value.
When the Lynx Smart BMS receives a pre-alarm signal, it will activate its alarm relay and it will generate an alarm message. The
alarm message is generated at least 30 seconds before the loads are shut down via the ATD signal.
A requirement for pre-alarm to be active, is that batteries are used that support this feature. Older batteries did not have this
feature. To check if the battery is equipped with pre-alarm; connect to the battery with the VictronConnect app and see if the pre-
alarm feature is supported by the app. If the pre alarm setting is missing from the VictronConenct app, then the battery does not
support pre-alarm.
Allow-to-charge and Allow-to-discharge
The Allow-to-charge and Allow-to-discharge contacts control the chargers and loads in the system:
When the battery is fully charged and the battery voltage gets too high or the temperature is to low, the allow-to-charge contact
is opened and charging has to stop.
When battery voltage is low, the BMS adds a 30s delay before opening ATD if pre-alarm is not supported. An alarm message
will be sent immediately.
For this feature to operate correctly, it is essential that the loads and chargers are able to be controlled by the allow-to-charge and
allow-to-discharge signals. Ideally wire the signal to a devices remote on/off connector, or if that is not available a BatteryProtect
or Cyrix-Li relay can be used.
Contactor
If charging or discharging is not stopped and the battery voltage gets even higher or lower, the safety contactor will be opened to
disconnect the entire DC system to make sure the batteries are protected. This will only happen when the batteries are critically
low or when the batteries are overcharging.
Lynx Smart BMS
Page 5 Features
8

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Victron Lynx Smart BMS 500 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Victron Lynx Smart BMS 500 in de taal/talen: Engels als bijlage per email.

De handleiding is 3.23 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info