5.9 Connection to the air exhaust system
1. Attach the air exhaust tube (accessory not included) to the hood connection. See image
2. Seal the joints.
8
Fix the reduction with the diameter of 150 mm on the connection of the hood. See
the picture
Fix the 120 mm diameter exhaust pipe on the reducer. See the picture
Seal the joints.
1.
2.
3.
5.10 Installation of the air adapter (reduction)
9a
5.11 Carbon filter kit (code: TCF1) for operation in air recirculation mode
In the air recirculation mode, carbon filters capture substances with unpleasant odors. By
regularly replacing the carbon filters, a high degree of elimination of unpleasant odors is
ensured. Carbon odor filters cannot be cleaned or regenerated.
5.12 Fitting the carbon filter kit TCF1 - optional
Turn off the unit.
Remove the grease filter.
Position the TCF1 carbon filters in the unit to the left and right of the engine. See the
picture
1.
2.
3.
9b
10a
4. Correctly align the filter with the engine mount and attach it.
See the image
5. Turn clockwise for a firm fit, each filter separately. See the image
10b
10c
6. After mounting both TCF1 filters, mount the baffle grease filters.
EN
5.13 Removing the carbon filter kit TCF1
Turn off the unit.
Remove the grease filter.
Turn counterclockwise each individual TCF1 filter and pull to the side of the engine. See
the picture
1.
2.
3.
11
4. Turn counterclockwise each individual TCF1 filter and pull to the side of the engine. See
the picture
5. Remove the TCF1 carbon filters from the unit. See the picture
11b
11c
5.14 Connection to the air recirculation system
Mount the carbon filters for odors (code: TCF1) - optional accessory
Attach the air exhaust tube to the hood connection (optional accessory)
Make the connection to the hole in the built-in furniture.
Fix the exhaust grille to the built-in furniture in such a way that its connection fits into
the exhaust pipe.
Seal the joints.
1.
2.
3.
4.
5.
Insert the plug into the socket with protective contact.
5.15 Making the electrical connection
5.16 Unit Disassembly
WARNING - Risk of injury!
Components inside the unit may have sharp edges.
Wear protective gloves.
1. isconnect the unit from the mains power supply.
2. Undo the air exhaust tube.
3. If necessary, open the filter cover (for models with this cover)
23