5.2 Unit dimensions (mm)
Observe the safety distances from the unit (calculated in mm).
5.3 Safety distances
Keep this information in mind when mounting the unit.
After unpacking, check that the delivery is complete and that all parts are free of possible
transport damage.
1. - hood
2. - reducer 150 - 120 mm
3. - non-return valve
5.1 Package Contents
5. INSTALLATION
CAREFUL!
This unit is designed to be installed and used on a wall.
See the images
1
See the image
2b 2c 2d
5.4 Installation steps
Note! Do not connect the power cable until the installation is complete!
Note! When the hood and the equipment powered by energy other than electric work
simultaneously, the negative pressure in the room must not exceed (4 x 10 Bar). Get a
second person to help you with the installation.
1.Drill 3 holes (Φ8mm to accommodate your wall mounts) to install the bracket. Screw and fix
the bracket to the wall using 3 screws (ST4x30mm) and 3 wall plugs (not included). See the
image
See the image 3
-5
4a
EN
2. Place the hood and hang it using the two mounting lugs on the wall bracket.
See the image 4b
3. Slide the top of the pipe mask to the bottom. Install the pipe mask bracket to the
bottom/outer side of it. See the image
4. Attach the duct mask to the hood body and mark the wall mounting holes.
Remove the tubing mask and drill the holes at the marked points.
5. To install the air exhaust system attach the exhaust pipe (this accessory is not included) to
the air outlet on the body of the hood. See the image 4d
6. Reattach the ducting mask to the hood body, passing the air exhaust tube (this accessory
is not included) through the mask and connecting it to the exhaust port, if necessary.
Fix the bracket at the bottom of the ductwork to the wall using 2 dowels and screws (4 x
30mm). See the image 4e
4c
7. Pull up the top/inner part of the pipe mask to the desired height, mark the mounting holes
for the top pipe mask bracket on the wall and pre-drill the marked points.
Fix the top pipe mask bracket to the wall with 2 dowels and 2 ST4 x 30mm screws at the
drilled points.
Fix the top/inner part of the ductwork to the bracket using 2 ST4 x 8mm screws.
See the image 4f
Make sure the bottom of the outer ductwork is resting on the body of the hood. It is not
necessary to screw the ductwork mask to the hood body.
2a
20