Exhaust duct
For the Truma boat water hea ter only the Truma Stain less
Steel Exhaust Duct AEM 24 (part no. 39430-00) and the com-
bustion air supply duct ZR 24 (part no. 39440-00) are to be
used, as the appliance has only been tested and approved
with these ducts.
The ends of the stainless steel exhaust ducts are sharp,
make sure to use working gloves when carrying out as-
sembly work.
Fig. A
Permissible duct lengths for wall cowl:
30 – 150 cm. Duct lengths of up to max. 50 cm can be rou ted
as required, as ascending duct or descending by max. 5 cm.
Route the duct with a bend (as shown in Fig. A) to pre vent
splash water from en tering.
Fig. B
Permissible duct lengths with deck cowl:
50 – 200 cm. The duct routing must be ascending at an angle
of at least 30°.
Connection of the exhaust gas double duct to
the water heater
Fig. C
Press end of ex haust duct (1) together so that winding touch-
es winding. Slide clamp (4) over exhaust duct (1). Slide ex-
haust duct over O-ring on the connection fitting (2) up to the
collar (3). Attach with clamp (4) in such a way that the knurled
edge of the clamp encloses the collar. Fasten combustion air
supply duct (5) on the connection fitting (6) using clamp (7).
Always install a new O-ring following any dis assembly!
Assembly of the wall cowl
Fig. C
Assemble wall cowl on as flat a surface as possib le, which is
well exposed to wind from all directions. Drill a hole of 70 mm
diameter (12). Sealing is carried out with the enclosed rubber
seal (13) without further sealing compound!
For greater wall thicknesses first connect ducts to the cowl
from the outside.
Slide rubber seal (13) and clamp (19) onto the cowl inner
part (15). Press end of exhaust duct (1) together so that wind-
ing touches winding, slide over the O-ring on the connection
fitting (18) up to the collar (bend pointing upward) and tighten
clamp (19) in such a way that the knur led edge of the clamp
enclo ses the collar.
Coat serrated connection fitting (14) with plastic body seal-
ant – do not use silicone! – and slide over combustion air
supply duct (5).
Fasten cowl inner part (15) with 3 screws (16) (observe instal-
lation position! The Truma lettering must be at the bottom).
Mount cowl outer part (17) and screw on with 2 screws (20).
Always mount cover cap (21) when the heater is not being
used.
Always install a new O-ring following any dis assembly!
Assembly of the deck cowl
Fig. D
Assemble deck cowl on as flat surface as possible, which is
exposed to wind from all directions. Drill a hole of 80 mm di-
ameter (22). Sealing is carried out using the enclosed cellular
rubber seal (23) without any further sealing combined.
In the case of greater roof thicknesses, first connect the ducts
to the cowl from the outside.
Pass cellular rubber seal (23) and clamp (19) over the ducts.
Press together the end of the exhaust duct (1) so that win-
ding touches winding and slide over the O-ring onto the
connection fitting (24). Fasten using clamp (19) in such a way
that the bead edge of the clamp grasps around the collar.
Slide combustion air duct (5) over the connection fitting (25)
and fasten with clamp (11).
Fasten cowl part (26) with screws (27). Screw on cowl
cover (28) with three screws (29). Always close the deck
cowl when the water heater is not being operated.
A new O-ring must always be installed after any
disassembly!
Water connection
All pressure and submergible pumps up to 2.8 bar are used
for operating the boiler and all mixed combination sets with
or without an electrical switch.
Fig. F
When using immersion pumps, a non-return valve (30 – not
included in the scope of supply) must be fitted between the
pump and the first branch point (arrow points in direction of
flow).
Fig. G
When using pressure pumps with high switching hysteresis,
hot water may flow back through the cold water tap. To pre-
vent the backflow, we recommend that a non-return valve
(31 – not included in the scope of supply) be fitted between
the outlet to the cold water tap and the drain valve.
Pressure and hot water-resistant hoses with an internal
diameter of 10 mm should be used for the boiler and the
safety/drain valve connections.
For fixed pipe routing (e.g. John Guest System) Truma can
supply the water connections (35 + 36), the safety/drain
valve (32) and a non-return valve (30 + 31) with a 12 mm
diameter inner connection as accessories.
If connecting to a central water supply (rural or city connec-
tion) or when using more powerful pumps, a pressure re-
ducer must be used which prevents pressures of greater than
2.8 bar occurring in the boiler.
Route the water hoses so that they are as short and
free of kinks as possible. All hose connections must be
secured using hose clamps (also for cold water)! Pressures
of up to 3.5 bar can occur in the safety/drain valve (also in
submergible pumps) because of the heat of the water and the
resulting expansion.
Hose clips (part no. 40712-01) are recommended for attaching
the hoses to the wall or the floor. If gas heating has been in-
stalled, the water hoses and the hose clips can be laid on the
hot air pipes, which prevents frost.
In order to guarantee that the boiler is completely emp-
ty, the enclosed elbow with breather valve (fig. E: 35)
must be used for the hot water connection!
All hot water pipes should be routed in a descending
manner to the safety/drain valve! There shall be no
claims under guarantee for damaged caused by frost!
18

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Truma BM 14 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Truma BM 14 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Deens als bijlage per email.

De handleiding is 0,78 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info