710116
19
Verklein
Vergroot
Pagina terug
1/43
Pagina verder
• Operating Instructions
These Operating Instructions describe how to use
the prodct properly and safely. The safety advice and
information as well as the accident prevention and
general safety regulations for the field of application
must be complied with.
(factory-set operating mode)
(factory-set operating mode)
The sliding gate operator can be actuated by an
impulse generator, such as hand transmitter, key
switch etc. It is only necessary to generate a short,
sharp impulse.
In same operating mode as for single-lane control,
however, receiver remains plugged into operator.
Operator starts up and gate travels to open position.
No effect, gate continues to open.
Gate closes.
Gate stops and then reopens.
Red-green traffic light control is only possible
together with the additional A800 traffic light control
system. Generating an impulse always causes the
gate to open. After the green and clearance phase
has elapsed, gate automatically closes. If a new
opening impulse is generated during the green
phase, this is extended.
you may only drive through the gateway
during the green phase.
All persons using the gate system
must be shown how to operate it
properly and safely.
Keep hand transmitters out of the reach
of children.
When the operator is being used, the
opening and closing phases must be
monitored. It must be ensured that
neither persons nor objects are located
within the gate’s range of travel.
Normal operation (0)
Normal operation (0)
OPEN-CLOSE operation (1)
Functional sequence:
Operation with single-lane control (1)
Caution:
Operating modes
Functional sequence:
Partial opening
IThe respective setting for menu 9 is shown in
brackets.
Operator starts up and causes gate to travel to set
open or closed travel limits.
Gate stops.
Gate continues to move but in opposite direction.
Partial opening of approx. 1 m instead of full opening
can be triggered by the hand tranmsitter or another
command generator.
First impulse:
IImpulse generated whilst gate is moving:
A new impulse:
Impulse generation in the closed position:
IImpulse generation whilst gate is opening:
Impulse generation in the open position:
Impulse generated whilst gate closes:
Automatic closing (2)
Automatic closing (3)
Automatic closing (4)
Functions of the safety devices
IInternal force limit device
Signal light
Disengaging the operator
Empty batteries must be disposed of separately
(toxic waste)!
Generating an impulse always causes the gate to
open.
IIf a photocell is installed, an interruption during the
closing phase causes the gate to stop and then travel
in the opposite direction. An interruption while the
gate is opening has no effect.
If a signal light to signal the opening and closing
phases is installed, this starts to flash as soon as a
start impulse is given. The operator starts up in
accordance with the set advance warning phase.
During the flashing phase, driving through the
gateway is not permitted.
When making adjustments and in the event of power
failures or malfunctions, the operator can be
disengaged and the gate be moved by hand. Open
and remove the cover with the triangular wrench.
Pull the pull cord with knob, 8 is displayed. The gate
can now be opened and closed by hand.
To resume power-operation, actuate the lever and
the operator re-engages. Replace the cover and lock
in place with the triangular wrench.
Programming further hand transmitters:
See menu stages 1 and 2 (figures 21 and 22).
Changing the battery: Slide back the battery
compartment cover on the hand transmitter.
Take out the battery.
Insert a new battery (alkaline 23A, 12V). Be sure to
pole correctly! Slide the cover back on.
After the hold-open phase and the advance warning
phase have elapsed, the gate automatically closes.
Generating an impulse always causes the gate to
open.
After the hold-open phase and the advance warning
phase have elapsed, the gate automatically closes.
If the photocell is interrupted, the hold-open phase is
prematurely terminated and the advance warning
phase commences.
Generating an impulse always causes the gate to
open.
After the hold-open phase and the advance warning
phase have elapsed, the gate automatically closes.
If an impulse is generated, the hold-open phase is
prematurely terminated and the advance warning
phase commences.
If the closing gate encounters an obstruction, the
operator stops and causes the gate to open to clear
the obstruction.
During the soft run of the closing phase, the gate is
opened a slight gap only, just sufficient to clear the
obstruction.
If during the opening phase the gate encounters an
obstruction, the operator stops and causes the gate
to reverse for approx. 1 sec.
Photocell
Hand transmitter
17
Maintenance / Checks
The gate system must be inspected and
tested by a specialist company prior to
initial operation and at least once a year
thereafter.
Monitoring the force limit
Caution!
The operator control unit features a dual-processor
safety system to monitor the force limit.
The integral force cut-out is automatically tested at
each travel limit.
The gate system must be checked prior to initial
operation and at least once a year thereafter, In the
process, the force limiting device (figure 20) must be
tested!
If the closing force is set too high,
persons can be placed at risk of injury or
property could sustain damage.
GB
Retain these installation, operating and maintenance instructions for the full duration of the operator’s service life!
19

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Tormatic NovoGate bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Tormatic NovoGate in de taal/talen: Nederlands, Duits, Engels, Frans, Spaans als bijlage per email.

De handleiding is 1,18 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info