3
English
DEFLATION AND STORAGE
1. Make sure the bed is unplugged from the electrical outlet
prior to deflation.
2. To deflate your
AeroBed
®
open the Quick Air Release
Valve at the foot of the bed to release the air in
approximately 15 seconds (1 minute for the
Premier
Raised Pillowtop
).
3. Roll or fold the AC cord with Comfort Control Wand and
secure it. Fold sides of bed into the centre along its length.
Tightly roll your
AeroBed around the pump towards Air
Release Valve end. When the bed is completely rolled, and
all air is expelled, push the Air Release Valve closed until it
locks.
4. Slide the duffel bag over your
AeroBed. Store your
AeroBed in a clean dry place at room temperature (above 50°F/10° C). Storing
your
AeroBed under 50° F (10° C) and over 100° F (38° C) may affect its
performance and will not be covered under guarantee.
5. If a mattress cover and/or valance is included with your bed, it/they may be
removed after deflation. Alternatively, you may store your product with the
mattress cover and/or valance on the bed. Wrinkling may occur.
CARE AND MAINTENANCE
1. Inspect your AeroBed prior to each use.
2. Keep your AeroBed away from any sharp objects. Large cuts or snags may not
be repairable and will not be covered by your guarantee.
3. When not in use, store your AeroBed in a clean, dry place out of extreme
temperatures. Product must be at room temperature prior to inflating.
4. Do not store your AeroBed folded inside sofa beds or roll-aways. This may
cause damage to your bed that will not be covered under your guarantee.
5. In case of incidental damage to your bed, a repair kit has been included. Please
follow repair instructions carefully.
2
English
INFLATION
1. Remove your AeroBed
®
from its lightweight duffle bag. Keep bag for storage.
NOTE: Bed must be at room temperature prior to inflating.
Place your rolled up bed on the floor or other surface free of obstructions or
sharp objects.
2. Make certain the Quick Release Valve located at the foot of the bed is closed.
Bed should be stored with valve in the closed and latched position.
If the Quick Release Valve is open, close it by using 2 thumbs to push cover and
snap into valve. Be careful to avoid pushing valve cover to the right or left as it
snaps into the valve opening.
3. Remove AC plug, cord and Comfort Control Wand from plastic bag and shrink
wrap.
4. Plug into any standard polarized 220-240 volt AC electrical outlet. (Note: this
product is rated at 230V ~ 50Hz, 1A. 110 Volt product sold outside Europe).
Never use with an extension cord unless the plug can be fully inserted.
5. Push and hold the button of the Comfort Control Wand for
approximately 60 seconds (3 minutes for
Premier
Raised Pillowtop
) to inflate the AeroBed to the full
(firmest) capacity. Bed will not over-inflate.
6. If applicable, the Premier Raised Pillowtop and Premier
Comfort
beds should be dressed with their covers' and/or
valance whilst they are still partially inflated.
7. Lie on the bed and use Comfort Control Wand to adjust the firmness to your
desired level. For firmer bed, press inflate/firmer button. For softer bed, press
deflate/softer button.
This is the closed position. Open Air Release Valve.