Küchen-Chef – Digital oven and meat thermometer
Küchen-Chef – Digital oven and meat thermometer
98
Sensor
E: Metal probe
F: Cable
G: Socket
4. Getting started
Pull the protective foil off the display. Open the battery compartment at the back of the
instrument and insert the battery 1.5 V AAA, polarity as illustrated. Close the battery
compartment.
The unit is now ready to use.
--.- and °F (default) and 122 °F (default) appear on the display.
Insert the probe connector cable plug into the socket on the left hand side of the device.
The current measured temperature and the defaults appear on the display.
You can toggle with the °C/°F button between °C or °F as temperature unit..
Press and hold the ALARM button to switch the instrument off and on.
4.1 Measuring of the oven temperature (OVEN)
Press the OVEN TEMP/STD button to adjust the desired target for the oven temperature.
Press and hold the button for fast running.
Do you only want to measure the oven temperature, place the probe in the oven
4.2 Measuring of the food temperature (FOOD)
Press the FOOD TEMP button to adjust the desired target for the food temperature.
Press and hold the button for fast running.
Push the sensor at least 2.5 cm into the middle of the thickest part of the meat, for poultry
between the torso and the thigh; it should touch neither bones nor cartilage and should
not protrude from the meat.
Put the meat into the oven and set the relevant oven temperature.
4.3 Measuring procedure
Route the cable to the outside. It adapts to the oven seal. Take care of sharp-edged
frames and hinges.
Use the magnet to fasten the thermometer in position near the oven (cable length 1 m)
or place the instrument on a flat surface.
Press the ALARM button to activate the alarm function.
The symbol (((.))) appears on the display.
As soon as the adjusted oven temperature is reached , one short alarm sound each second
(until 20 seconds) will sound.
As soon as the adjusted food temperature is reached , two short alarm sounds each second
will sound.
The corresponding temperature display and the alarm symbol (((.))) flash and a warning
symbol
appears.
Press any button to stop the alarm.
The temperature display still flashes.
If the measured temperature is still being higher than the set temperature after 2 minutes,
the alarm will automatically turn on again.
Press the ALARM button do deactivate the alarm function.
The symbol (((.))) disappears.
The temperature display will continue flashing until the measured temperature is below
the set temperature.
The warning symbol
disappears.
Thank you for choosing this instrument from the firm TFA.
1. Before you use it
Please be sure to read the instruction manual carefully.
Following and respecting the instructions in your manual will prevent damage to your
instrument and loss of your statutory rights arising from defects due to incorrect use.
We shall not be liable for any damage occurring as a result of not following these
instructions.
Likewise, we take no responsibility for any incorrect readings and for any consequences
which may result from them.
Please take particular note of the safety advice!
Please keep this instruction manual for future reference.
2. For your safety
This product should only be used as described in your instruction manual.
Unauthorised repairs, modifications or changes to the product are prohibited.
This product is not be used for medical purpose or for public information, it is only
intended for home use.
Caution!
Risk of injury:
Wear heat-resistant protective gloves when you touch the sensor during or after cooking
Do not use the instrument in the microwave
Be careful when handling the probe
Keep this instrument and its battery out of reach of children.
Batteries must not be thrown in fire, short-circuited, taken apart or recharged. Danger of
explosion!
Batteries contain harmful acids. Low batteries should be changed as soon as possible to
prevent damage caused by a leaking.
Remove the battery if you do not use the instrument for a longer period of time.
Wear chemical-resistant protective gloves and glasses when handling with leaked batteries.
Important information on product safety!
Do not place your product near extreme temperatures, vibration or shock. Only the probe
and the cable are heat resistant until 380 °C. Never place the probe directly over fire.
Do not immerse the cable and the probe into water. Water can penetrate into the preci-
sion sensor and cause malfunction. Not suitable for dishwasher.
3. Elements
A: Display above - Temperature of the oven (OVEN)
Current temperature - Temperature unit - Target temperature
B: Display below - Temperature of the food (FOOD)
Current temperature - Temperature unit - Target temperature
Housing
C: Battery compartment with magnet
D: Connector socket for probe
TFA_No. 14.1503 Anleitung_05/13 17.06.2013 17:15 Uhr Seite 5
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw TFA 14.1503 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van TFA 14.1503 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 0,19 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info