1918
Troubleshooting
Malfunction Cause Remedy
Sensor without power ■ Fuse faulty, not switched
'ON', break in wiring
■ Short circuit
■ New fuse, turn 'ON' power
switch, check wiring with
voltage tester
■ Check connections
Sensor will not switch 'ON' ■ Twilight control set to night-
time mode during daytime
operation
■ Bulb faulty
■ Power switch 'OFF'
■ Fuse faulty
■ Detection zone not properly
targeted
■ Reset
■ Change bulb
■ Switch 'ON'
■ New fuse, check connection
if necessary
■ Re-adjust
Sensor will not switch 'OFF' ■ Continuous movement in the
detection zone
■ Light being operated in the
detection zone causing sen-
sor to respond as a result of
change in temperature
■ Light being operated is in
the manual override mode
(LED 'ON')
■ Check zone, adjusting if
necessary, or shroud
■ Change zone, or shroud
■ Deactivate manual override
Sensor keeps switching
'ON'/'OFF'
■ Lamp being operated in
the detection zone
■ Animals moving in the
detection zone
■ Change zone, shroud or
increase distance
■ Change zone, or shroud
Sensor responds when it
should not
■ Wind is moving trees and
bushes in the detection zone
■ Cars in the street are being
detected
■ Sunlight is falling onto
the lens
■ Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
■ Dazzle guard active
■ Change detection zone
■ Change detection zone
■ Mount sensor in a sheltered
place or change detection
zone
■ Change detection zone,
change site of installation
■ Operate manually at push-
button/switch
■ No movement detected
within the selected stay-'ON'
time + 60 sec. (dazzle guard)
Change in sensor's reach ■ Differing ambient
temperatures
■ Use shrouds to define
detection zone precisely
LED flashing rapidly
(approx. 5 x per second)
■ Load connected is too high ■ Reduce load or use
contactor
This product complies with
- Low-Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
Declaration of Conformity
Technical specifications
IS 3360/
IS 3180 IS 3360 ECO IS 345 IS 345 MX
Dimensions: (L x W x H) 95 x 95 x 65 mm
Output:
Incandescent lamps, 2000 W max. at 230 V AC
Fluorescent tube, 1000 W max.
at cos ϕ = 0.5, inductive load at 230 V AC
8 x 58 W max., C ≤ 176 µF
at 230 V AC
*1)
Power supply: 230 – 240 V, 50 Hz (2.5 mm
2
max.)
Angle of coverage: 180° with 90° 360° with 180° 180° with 45° 180° with 45°
angle of aperture angle of aperture angle of aperture angle of aperture
Reaches:
Detection levels: 7 11 5 5
Switching zones: 448 1416 280 120
Time setting: 5 sec. – 15 min. + pulse mode (approx. 2 sec.)
Twilight setting: 2 – 2000 lux + teach mode
Manual override: selectable (4 hrs.)
IP rating: IP 54
Protection class: II
Temperature
range: - 20 °C to + 50 °C
*
1)
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
IS 3360
20 m max.
tangentially;
temperature-
stabilised
IS 3360 Eco
10 m max.,
temperature-
stabilised
+ precision
adjustment using
shrouds
Basic setting 1:
8 – 20 m max.
tangentially;
temperature-
stabilised
Basic setting 2:
4 – 8 m max.;
temperature-
stabilised)
+ precision adjust-
ment by re-pos-
itioning the lens
and using shrouds
max. of 30 x 4 m
(radially) mounted
at a height of
12 m;
temperature-
stabilised
20 x 4 m max.
(tangentially),
12 x 4 m max.
(radially);
temperature-
stabilised
Precision adjust-
ment by re-pos-
itioning the lens
and using shrouds
GB