Display (LED) Status
Cause / Fault
Solution
Who
Anode Service
Fast Heating
On
On
On
Off
On
On
Flashing
Flashing
Technician
Technician
Technician
Technician
Technician
Technician
Flashing
Off
Off
On/Off
(see below)
Internal electronic locked
The reservoir has heated
without water
Water temperature
in reservoir too hot
Internal electronic failure
Internal electronic failure
Anode fault
Electronic board locked, wait 15mins and
then reset
Turn the device off, check the cause of the
water shortage (leakage, faulty water
connection). If the problem remains contact
technician
Reset, wait until the reservoir has cooled.
If the problem remains please contact
technician
Reset, if the problem remains please contact
technician
Reset, if the problem remains please contact
technician
Check that the reservoir is filled. If the problem
remains please contact technician
Note
In an “error condition”, the device is out of order.
In the case of an “anode fault”, the device can be manually activated for a heating cycle by pressing the “fast-heating” button
. In this case the device heats until a water temperature of 40°C is reached and fast heating LED . The device
heats at the installed power for single-power and boiler mode connections, for double-power connections it heats according to
the basic load of the connection, at 1kW or 2kW.
If the fault could not be removed, please contact the customer service operators.
Note
When the device is full with water and functions normally (there are no faults apparent), the device cannot be separated from
the mains voltage for long periods of time, otherwise the external power source anode stops functioning and the device rusts
through. For complaints of this nature, the warranty and guarantee do not apply.