english 13
condition ready.
The intervals mentioned here apply for normal operating
conditions; if the machine is heavily used, the intervals
will be shorter accordingly.
Clean the machine panels, covers, and control levers with
a soft cloth, dry or moistened with a little neutral cleaning
agent. Do not use solvents such as alcohol or petrol, as
this might damage the surfaces.
Keep oil and grease out of reach of unauthorized per-
sonnel. Read the instructions on the product containers
carefully and observe them precisely. Avoid direct contact
with skin and wash off well after use.
Accident Prevention Standards
The machine may only be operated by qualified personnel
who are well aware of the contents of this manual.
Before operating the machinery, you must check the in-
tegrity of the safety mechanisms and ensure that they are
working properly.
Also before operation, you should familiarise yourself with
the machine controls, following the operating instructions.
The specified capacity of the machine must not be ex-
ceeded. Under no circumstances the machine must be
used for anything else but its indented use.
All personnel must wear work clothes as stated in the
regulations of the country in which the machine is oper-
ated. Wide, loose clothing, belts, rings, and necklaces
should not be worn. Long hair should be tied back.
Try to keep the working area tidy at all times. Tools, acces-
sories, and spanners should be kept within reach.
During cleaning or maintenance work the machine must
not be connected to the mains supply.
It is strictly prohibited to operate the machine without
safety mechanisms or with safety mechanisms disen-
gaged.
It is strictly prohibited to remove or modify safety mecha-
nisms.
You should not carry out any maintenance or adjustments
before having carefully read this manual.
The given maintenance schedule must be observed for
safety reasons as well as to ensure that the machine per-
forms properly.
The warning labels must be always clean and legible and
must be observed in order to avoid accidents. If labels
are damaged or missing or belong to parts that were re-
placed, then those labels must be replaced by original
labels ordered from the manufacturer and be attached at
the positions prescribed.
In case of fire, dry powder fire extinguishing agents must
be used. A burning machine must not be extinguished
with water because of the risk of a short circuit.
If the fire cannot be extinguished immediately, watch for
liquids leaking.
If the fire is more widespread, the oil tank or the pressur-
ised lines can explode: Therefore, make sure that you are
not getting into contact with the leaking liquids.
Dismantling and Disposal
The machine does not contain any materials that are
hazardous to health or the environment, because it is
manufactured from materials that are either completely
recyclable or can be disposed in a normal way.
For disposal, you should use specialist companies or qual-
ified personnel, who know the possible risks and have read
these operating instructions and follow them precisely.
If the machine falls into disuse, follow these steps under
observance of all applicable accident prevention meas-
ures:
• Disconnect the energy supply (electrical or PTO),
• Remove all electrical wires and hand over to a special-
ised collecting point, while observing national regula-
tions.
• Drain the oil tank and deliver the oil in a closed con-
tainer to a collecting point, while observing national
regulations.
• Deliver all other machine parts to a scrap collection
point, while observing national regulations.
Make sure every part of the machine is disposed of in ac-
cordance with all applicable national regulations.
EC Declaration of Compliance
Herewith, we, Scheppach Fabrikation von Holzbearbeitungs-
maschinen GmbH, Günzburger Str. 69, D-89335 Ichenhausen,
Germany, declare that the machinery identified below based on
its design and type and in the version delivered by us conforms to
the relevant provisions of the EC directives mentioned below.
Any modification of the machinery will invalidate this declaration.
Designation of the machinery:
Hydraulic log splitter
Machine type:
OX 3–1000
Order number:
1604 0938
Relevant EC directives:
EC machine directive 2006/42/EG,
EC Low voltage directive 2006/95/EWG,
EC-EMV directive 2004/108/EWG.
Applied harmonised European standards:
EN 12100:2004, EN 13857, EN 574:1997, EN 609-1:1999, EN 982:1996,
EN 60204-1:1998
Notified body as per annex VII:
Spitzenverband der landwirtschaftlichen Sozialversicherungen,
34114 Kassel, Germany
Place, date:
Ichenhausen, 20.07.2009
Signature:
p.p. Werner Hartmann (product manager)
OX 3-1000 2011.indd 13 07.11.11 12:03
13

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Scheppach OX 3-1000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Scheppach OX 3-1000 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Deens als bijlage per email.

De handleiding is 8.61 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info