781486
15
Verklein
Vergroot
Pagina terug
1/86
Pagina verder
www.scheppach.com service@scheppach.com +(49)-08223-4002-99 +(49)-08223-4002-58
15 І 86
When the sawblade and key are not in use, they can
be stored as in g 23.
Store the operating manual with the electrical tool.
14. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer‘s mains connection as well as the
extension cable used must also comply with these
regulations.
The product meets the requirements of
EN 61000-3-11 and is subject to special connec-
tion conditions. This means that use of the product
at any freely selectable connection point is not al-
lowed.
Given unfavorable conditions in the power supply the
product can cause the voltage to uctuate temporarily.
The product is exclusively intended for use at con-
nection points that have a continuous current-carry-
ing capacity of at least 100 Amper phase.
As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to ope-
rate the product meets the specied requirements.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been improp-
erly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Make sure that the connection cable does not hang
on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F“.
The printing of the type designation on the connection
cable is mandatory.
AC motor
The mains voltage must be 230 V~
Extension cables up to 25 m long must have a
cross-section of 1.5 mm2.
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event of
any enquiries:
Type of current for the motor
Machine data - type plate
Machine data - type plate
10.2 Making cross cuts (Fig. 22)
- Slide the cross stop (7) into one of the grooves
(31a/b) in the table and adjust to the required angle.
(see 9.5). If you also want to tilt the blade (3), use the
groove (31a) which prevents your hand and the cross
stop from making contact with the blade guard.
- Use the stop rail.
- Press the workpiece rmly against the cross stop (7).
- Switch on the saw.
- Push the cross stop (7) and the workpiece toward the
blade in order to make the cut.
- Important:
Always hold the guided part of the workpiece.
Never hold the part which is to be cut off.
- Push the cross stop (7) forward until the workpiece is
cut all the way through.
- Switch off the saw again. Do not remove the offcut
until the blade has stopped rotating.
10.3 Cutting particle boards
To prevent the cutting edges from cracking when work-
ing with particle boards, you should not set the saw
blade (3) more than 5mm greater than the thickness of
the workpiece (also see 9.2).
11. Transport
1. Turn off the power tool before any transport and
disconnect it from the power supply.
2. Apply the power tool at least with two people, do
not touch the table extensions.
3. Protect the power tool from knocks, bumps and
strong vibrations, such as during transport in vehi-
cles.
4. Secure the power tool against overturning and slid-
ing.
5. Never use the safety devices for handling or trans-
porting purposes.
12. Maintenance
m Warning! Prior to any adjustment, maintenance or
service work disconnect the mains power plug!
12.1 General maintenance measures
Keep all safety devices, air vents and the motor hous-
ing free of dirt and dust as far as possible. Wipe the
equipment with a clean cloth or blow it down with com-
pressed air at low pressure.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
In order to extend the service life of the tool, oil the
rotary parts once monthly. Do not oil the motor.
12.2 Brush inspection
In case of excessive sparking, have the carbon brushes
checked only by a qualied electrician. Important. The
carbon brushes should not be replaced by anyone but a
qualied electrician.
13. Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
www.scheppach.com service@scheppach.com +(49)-08223-4002-99 +(49)-08223-4002-58
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Scheppach HS100S bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Scheppach HS100S in de taal/talen: Duits, Engels, Pools als bijlage per email.

De handleiding is 5.78 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info