www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
20 І GB
Old devices must not be disposed of with house-
hold waste!
This symbol indicates that this product must
not be disposed of together with domestic
waste in compliance with the Directive
(2012/19/EU) pertaining to waste electrical
and electronic equipment (WEEE). This product must
be disposed of at a designated collection point. This
can occur, for example, by handing it in at an author-
ised collecting point for the recycling of waste elec-
trical and electronic equipment. Improper handling
of waste equipment may have negative consequenc-
es for the environment and human health due to po-
tentially hazardous substances that are often con-
tained in electrical and electronic equipment. By
properly disposing of this product, you are also con-
tributing to the effective use of natural resources.
You can obtain information on collection points for
waste equipment from your municipal administration,
public waste disposal authority, an authorised body
for the disposal of waste electrical and electronic
equipment or your waste disposal company.
* Not necessarily included in the scope of delivery!
Cleaning the nozzle (Fig. 1)
Use the supplied wire (11) to clean clogged nozzles.
Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip-
ment and its accessories are made of various types
of material, such as metal and plastic. Never place
defective equipment in your household refuse. The
equipment should be taken to a suitable collection
center for proper disposal. If you do not know the
whereabouts of such a collection point, you should
ask in your local council ofces.
Possible causes of failure
Troubleshooting Cause Remedy
Device does not work
No electrical voltage at the device.
Check the fuse, power cable and
power plug and have them replaced
by qualied personnel if necessary.
Cross section of the extension cable
not large enough and/or the exten-
sion cable is too long.
Use extension cables with larger
cross sections and/or use shorter
extension cables.
The mains voltage is lower than that
specied.
Contact the power supply company if
necessary.
The pump is frozen. Check and thaw if necessary.
The motor starts but there is no build
up of pressure
Air intake in the water inlet. Check the supply hose and hose
connection and replace if necessary.
Discharge nozzle is too large. Check and replace if necessary.
Irregular operating pressure Air intake in the water inlet. Check the supply hose and hose
connection and replace if necessary.