evenly using both hands with the ngers together.
Hold the workpiece with your hands on a safe
area.
• Use a pattern for repeated arced or irregular cuts.
Insure that the workpiece does not roll when
cutting round pieces.
Use the traverse cutting gauge special acces-
sory for safety when making traverse cuts.
To safely cut round plates, use the circular cut-
ting unit special accessory.
Electrical Connection
The installed electric motor is connected
and is ready to work.
The connection complies with the relevant VDE
and DIN regulations.
The customer-side mains supply and the used
extension line must meet these regulations.
Installations, repair, and maintenance work
relating to the electric installation may only be
performed by specialists.
Important Notes
The electric motor has been designed for the S 1
operating mode.
In case of an overload of the motor, it turns off
automatically. After a cooling period (duration
varies), you can turn on the motor again.
Defective Electric
Connection Lines
Often, insulation damages occur on electrical
connection lines.
Causes are:
1. Drag marks if connection lines are led through
window or door clearances.
2. Kinks due to improper attachment or routing of
the connection line.
3. Cuts caused by running over the connection
line.
4. Insulation damages caused by pulling the con-
nection line out of the wall socket.
5. Fissures caused by the ageing of the insulation.
Such defective electric connection lines must
not be used and are hazardous due to the
insulation damages.
Regularly check the electrical connection lines for
damages. Please make sure that the connection
lines are disconnected from the mains supply
during the check.
Electrical connection lines must comply with the
relevant VDE and DIN regulations. Only use con-
nection lines labelled with H 07 RN. The labelling
of the connection cable with the type specication
is required.
AC motor
1. The supply voltage must be 230 V / 50 Hz.
2. Extension lines up to a length of 25 m must
have a cross section of 1.5 square millimetres.
Extension lines with a length of more than 25
m must have a minimum cross section of 2.5
square millimetres.
3. The mains connection is protected with a delay-
action fuse of 16 A.
Rotary current motor
1. The supply voltage must be 400 V / 50 Hz.
2. Mains supply and extension line must be ve-
wire = 3 P + N + SL.
3. Extension lines must have a minimum cross
section of 1.5 square millimetres.
4. The mains connection is protected with a maxi-
mum of 16 A.
5. In case of mains supply or change of location,
the direction of rotation must be checked. If
required, the polarity must be reversed.
If you have further questions, please specify
the following:
1. Motor manufacturer
2. Kind of current of the motor
3. Data from the machine type plate
4. Data from the switch type plate
If you return the motor, always return the com-
plete drive unit with the switch.
Maintenance
Carry out retting, setting measurement and
cleaning work only when the motor is switched
off. Pull the plug and wait for the sawband to
come to a full stop.
An experience worker can carry out minor-
repairs on the machine himself.
Repair and maintenance work on the electrical
system may only be carried out by a qualied
electrician.
All protective and safety devices must be re-
attached immediately after completed repair
and maintenance work.
GB
GB
29

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Scheppach Basa 5.0 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Scheppach Basa 5.0 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 4.84 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info