PARTS OF THE TOOL
1 - Identification plate
2 - ON/OFF switch
3 - Speed control
4 - Tool body
5 - Suction tube connection int. Ø 29 mm
6 - Suction control
7 - Suction cowling
8 - Velcro faced abrasive disc backing pad Ø 200 mm (TA562AN)
9 - Velcro faced abrasive disc backing pad Ø 150 mm (TA531A -
TA551A)
10 - Compressed air connection with 1/4” thread
11 - Disc pad locking/release button
STARTING UP
Before starting-up the tool, ensure that:
- the packaging is complete and does not show signs of having
been damaged during storage or transport;
- the tool is complete; check that the number and type of components
comply with that reported in this instruction booklet;
- the available compressed air production and distribution plant is
capable of satisfying the requirements reported on the tool’s
identification plate reproduced and explained on page 11.
ASSEMBLING THE TOOL
Assemble the compressed air connection (not supplied) by
screwing it into its seating (10).
COMPRESSED AIR CONNECTION
The tool is supplied without the compressed air connection; the
user can use either a quick release coupling or hose type
connection according to his needs, purke they have an hole of air
passing mm. 8. In the latter case the air line must be fixed to the
nozzle by a hose clip.
MOUNTING THE BACKING PAD (TA531A - TA551A)
1.Press the lock button (11);
2.screw the backing pad on by hand while keeping the release
button pressed (9);
3.reverse the procedure when removing the backing pad.
REMOVING AND MOUNTING THE DISC PAD (TA562AN)
- Unscrew the screws on the disc pad;
- reverse the procedure when fitting the disc pad.
FITTING ABRASIVE PAPER DISCS
Press the abrasive disc into the pad ensuring that the holes in the
paper coincide with extraction holes in the disc pad.
BEFORE STARTING THE TOOL
Ensure that:
- the compressed air feed line and connection are in perfect
working order;
- the start switch (2) is working properly. This must be done with
the air supply switched off;
- all the components of the tool are mounted correctly and do not
show any signs of damage.
STARTING AND STOPPING
- Starting
: rotate knob (2) in the direction indicated by the arrow.
- Stopping
: release the knob.
TEST RUN
Start the tool and check that there are no unusual vibration, no di-
smatching of the abrasive paper disc.
Otherwise switch-off the tool immediately and eliminate the
cause.
9