Nozzle Performance
(Standard) (Metric)
Precipitation rates calculated at 50% diameter “head to head” spacing, half circle operation.
Tasa de precipitación en base a un diámetro de alcance de 50%, con el aspersor operando en círculo parcial.
Pluviometria baseada em 50% do diâmetro de alcance, com o aspersor operando em meio-círculo.
Pluviometria calcolata con interdistanza pari al 50% della gittata e una rotazione di 180°.
Pluviomètrie horaire calculée pour des arroseurs fonctionnant en demi-cercle et écartés de 50% du diamètre arrosé.
Die Beregnungsdichte bezieht sich auf 180° bei einem Regnerabstand von 50% des beregneten Durchmessers.
Neerslagintensiteiten berekend voor afstand tussen sproeiers van 50% van diameter, met sectorinstelling 180 graden.
Presipitasyon oranları, rotorlar arası mesafenin, çaplarının %50’si oldugu düsünülerek ve yarım tur çalıstıkları
varsayılarak hesaplanmıstır.
H ™ntash thq broxøptvshq ypologºzetai sto 50% thq diam™troy se diåtazh \apø ektozeyt¸ra se
ektozeyt¸ra|, leitoyrgºaq miso¥ k¥kloy.
English Installation Instructions
Installing and Removing Nozzles:
1. Insert tool into pull-up slot, turn 90 degrees, and lift up stem. (A)
2. Insert the desired nozzle into the nozzle socket, and turn the radius
adjustment screw clockwise to secure the nozzle in place. (B)
3. Insert the selected nozzle’s identification plug into the opening on
the top of the rotor.
4. To remove the nozzle, back out the radius adjustment screw,
place the blade of the screwdriver under the nozzle removal tab
and press the handle down. (C)
Setting the Arc
:
The arc is adjustable from 40 –360 degrees (PC units only). The rotor
is factory set to 180 degrees.
Align Fixed LEFT Edge:
1. Pull up turret and turn to the left trip point (counterclockwise).
CAUTION: If the rotor does not turn easily to the left, first turn it
right (clockwise) to the right trip point.
2. Rotate entire case to the desired fixed left position, OR unscrew
cap and pull out assembly. Rotate internals to re-align left trip
point to the desired point and re-install.
To increase or decrease the arc: (D)
1. While holding the nozzle turret at the fixed LEFT stop, insert tool
or screwdriver into the adjustment socket.
2a. Turn the screwdriver clockwise, (+) to INCREASE arc.
2b. Turn the screwdriver counterclockwise, (-) to DECREASE arc.
3. Each full clockwise turn of the screwdriver will add or remove 90
degrees of arc.
4. When the maximum arc of 360 degrees or minimum arc of 40
degrees has been set, you will hear a ratcheting noise. Do not
adjust the rotor beyond the maximum or minimum arc.
Radius Adjustment: (Radius can be reduced up to 25%) (E)
1. Insert screwdriver into the radius adjustment socket.
2. Turn the screwdriver clockwise to reduce radius, and
counterclockwise to increase radius.
T
urning Flow On or Off (F)
1. Insert screwdriver into Flow Shut-off Slot.
2. Turn screwdriver clockwise 180 degrees to stop the flow of water.
3. Turn screwdriver counterclockwise 180 degrees to start the flow
of water.
A
B
C
D
E
F