815520
2
Verklein
Vergroot
Pagina terug
1/28
Pagina verder
27094-803D 12/23
A.Échantillondenumérodesérie/étiquettedesécurité
EMPLACEMENT : SOUS LE REBORD À CENDRES, TIRER POUR VOIR
REMARQUE : Les espaces de dégagement ne peuvent être réduits que par des moyens approuvés
par l'autorité réglementaire.
and Welcome to the Quadra-Fire Family!
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation, venting and operating
instructions.
CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA
Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling.
WARNING - For Mobile Homes: Do not
install in a sleeping room. An outside combustion air inlet must be provided and
unrestricted while unit is in use. The structural integrity of the mobile home floor, ceiling
and walls must be maintained. The insert must be properly grounded to the frame of the
mobile home. A complete relining of the chimney system with a 6 inch (152mm) diameter
listed stainless liner is required. Must be equipped with a spark arrestor cap. Outside Air
comes standard on the insert and must be installed before operating insert.
When used as a masonry insert stove, install only in a masonry fireplace built to national
and/or local codes. Do not remove brick or mortar to accommodate insert. Installation
requires a 5 foot minimum length of a starter pipe into existing chimney with airtight face
seal. A full reline with listed liner strongly reccomended.
Install only on a non-combustible hearth.
Approved for installation and use in factory built zero-clearance fireplaces conforming to
minimum fire chamber specifications. A complete relining of the chimney system with a 6
inch (152mm) diameter listed stainless liner is required.
In Canada a full length 6 inch (152mm) S635 flue liner is required as per ULC S628-93.
WARNING - Inspect and clean chimney frequently. Under certain conditions of use, creosote
buildup may occur rapidly.
Do not connect this unit to a chimney serving another appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route
power cord away from unit. Do not route cord under or in front of appliance. Electrical
Rating: 115 VAC 1.4 AMPS 60 Hz
Do not use grate or elevate fire. Build wood fire directly on hearth (firebrick).
Do not
overfire. If heater or chimney connector glows, you are overfiring.
Operate only with doors
closed. Open only to add fuel to the fire. Replace glass only with 5mm ceramic available
from your dealer.
DO NOT REMOVE THIS LABEL
HOT WHILE IN
OPERATION DO NOT
TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE
NAMEPLATE AND INSTRUCTIONS.
CAUTION:
Factory-Built Floor
Protection under Hearth
Extension
Thermal & Ember Protection
Floor height 0 to 4.5 inches below
Insert Base: Materials with R value of
2.9 required.
Ember Protection Only
Greater than 4.5 inches below Insert
Base.
LISTED ROOM HEATER, SOLID FUEL TYPE
"For Use with Solid Wood Fuel Only."
Also for use in Mobile Home.
Made in U.S.A. of US and
imported parts.
7094-800A
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 crib wood particulate emission standards at 1.9 g/hr for single burn rate heaters.
This single burn rate wood heater is not approved for use with a flue damper.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s manual for further
information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner’s manual.
Mfg by:
352 Mountain House Road
Halifax, PA 17032
www.quadrafire.com
R
Serial No. / N° de série
HF
BARCODE LABEL
EXPEDITION I
CONFORMS TO UL STD 1482 AND CERTIFIED TO ULC STD S628
21-670
21-661
Side Wall
FF
Fuel Door
Insert
BB
Fascia
or Trim
Maximum Mantel Depth - 12 inch (305mm)
Mantel
Hearth Extension
AA
C
C
D
D
E
E
Minimum Clearances To Combustible Material
Masonry, Heat Circulating & Factory-Built
Refer to Clearances on other label for Canada
A Sidewall to Center of Appliance 24.5 in.
B Mantel to Bottom of unit 44.75 in.
C Top Trim to Bottom of unit 42.5 in.
D Side Trim to Center of Appliance 23.75 in.
E Hearth Extension from Glass 16 in.
F H
earth Extenson from Fuel Loading Door
8 in.
USA ONLY
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
2022 2023 2024
ÉCHANTILLON
Nº du test de
laboratoireet
du rapport
Datedefabrication
Numéro de série
Nom du modèle
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Quadra-Fire Expedition I bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Quadra-Fire Expedition I in de taal/talen: Frans als bijlage per email.

De handleiding is 5.76 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Quadra-Fire Expedition I

Quadra-Fire Expedition I Gebruiksaanwijzing - English - 28 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info