709188
9
Verklein
Vergroot
Pagina terug
1/90
Pagina verder
GB
The instructions for installation, operating and maintenance must be kept in a safe place as long as the door is in use!
- 1 -
Installation instructions for sectional doors type
iso9-2 / iso20-2 with extension spring,
disassembled version
The door manufacturer accepts no liability for incorrect
mounting.
- Mounting should only be carried out by qualified fitters
Please read carefully before mounting
Scope of delivery:
Section package, frame package, panel package
The following items are required for mounting
the following tools (place inside the garage before
mounting the door if there is no other entrance to the
garage)
folding rule/tape measure, water level, water pump pliers,
reversible ratchet handle with extension and wrench socket
inserts size 7, 10 and 13 ( fork or wrench socket also
possible) fork or open spanner from size 13 for tightening
springs (cf. Item 29), cross-tip screwdrivers size 2 and 3,
slot screwdriver, hammer drill with drill bits, 10mm
(drilling depth of at least 65mm), at least 2 screw clamps,
possibly square timber, hammer, metalsaw, small nippers,
chisel and
Mounting material suitable for the building situation. Note:
Check that the wood screws S8 supplied and the plugs
S9 are suitable for the building situation before use.
Important :
The door may only be mounted in a finished opening
and on a finished floor!
As a precautionary measure, compare the garage
dimensions with the coordinating size of the door before
mounting.
minimum inside width of garage
= coordinating size –width + 180mm
minimum garage ceiling height
=coordinating size –height + 120mm (also suffices for
door operators)
minimum side room right and left = 55mm
Letter/numeral combinations, e. g. S8
, refer to the
respective mounting and installation materials in the
illustrated section, a successive subscript L or R, e.
g. 1
L
, indicates a part for the left or right side (observe
markings on parts). The omission of a subscript L or R
indicates a part that can be used either left or right.
Figures in brackets, e. g. [
1.10
], refer to the respective
illustration in the illustrated section.
Mounting of door frame
( 1 ) Lay the angular frames 1
R
+ 1
L
on to wood or something
similar (to protect them from scratches) and screw together
the angular frame 1
R
+ frame panel 3 + angular frame 1
L
(tapping screws have already been pre-mounted) [
1.10a
].
( 2 ) Screw the leading plate 4 with S13
on top on the angular
frames 1
R
+ 1
L
[
1.10b
].
( 3 ) Loosely screw the wall anchor 7 to the angular frames
1
R/L
right and left with S6 + M12 according to the side
room.
( 3a ) Side room 55 - 120mm: Set the wall anchor 7 to the
inside
[
1.10ca
]
.
( 3b ) Side room more than 120mm: set the wall anchor 7
to the side
[
1.10cb
]
.
If other mounting materials are used, make sure they
have at least the same load-carrying capacity as the
supplied wall anchor 7.
( 4 ) Set up the door frame behind the opening, secure it so it
cannot fall over, and use the water level to align exactly
parallel and at a right-angle [
1.15
] (also ensure that the
frame panel 3 is level). Centre and clip panel retainers 13
to the upper frame part [
1.15d
]. Finally fasten with S8 + S9
[
1.15a,c,d,e
]. Put the srew S8 in the plastic bush 81 and fix
the foot of the frame
[
1.15b
]
. Note: do not twist or bend the
angular frames 1
R/L
; it might be necessary to fill the
space between frame and masonry with suitable
material before tightening the screws!!!
( 5 ) Screw each of the right 14
R
and left 14
L
pair of horizontal
tracks to end piece 16
R/L
[
1.20a
] + upper rope fixation 5
[
1.20a
] + spring channel bracket 8 each front & back
[
1.20b,c
]+ end connection bracket 10
R/L
[
1.20d
] with S6 +
S12.
( 6 ) Stick on foamed rubber 9 on spring channel bracket 8
[
1.20b
], mount spring channel 12 with S6 + S12 and put on
the edge protection 24 on the front [
1.20e,f
].
( 7 ) Mounting of anchor tracks
( 7a ) If the distance between the wall and the pair of
horizontal tracks 14
R/L
is smaller than 500mm
(internal width of the garage max. coordinating size+
1030mm if door is fitted in the middle) push an
anchor track 27 with connecting brackets 28 right
and left into the track connector 6 and screw the
clamping plate 29 to S6
+ S12 in such a way that the
anchor tracks can still be pulled out
[
1.20a,b
]
.
( 7b ) If the distance between the wall and the pair of
horizontal tracks is more than 500mm the track
connector 6 can be later fixed to the ceiling (Cf .
Point. 14).
( 8 ) Screw the horizontal pair of tracks 14
R/L
to the end pieces
16
R/L
with the header bracket S5 + S12 so that later the
door remains raised when lifted up [
1.25c
]. If the distance to
the wall to small than use the hammer head screw S7
[
1.25c
]
.
( 9 ) Screw the track connector 6 each with S6 + S12 to the end
connection brackets 10
R/L
[
1.25d
].
( 10 ) Premount springs [
1.30
].
Place both triple extension spring assemblies 11 with the
plastic sliding elements downwards on the floor of the
garage (with the spring tightening strap pointing to the back
wall of the garage). Screw a deflection pulley cable
assembly 12 with the black side showing upwards to one
of the triple extension spring assemblies 11 with S5
+ S12.
This is the right spring assembly. Both cable ends are
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Novoferm iso 9-2 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Novoferm iso 9-2 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 2,67 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Novoferm iso 9-2

Novoferm iso 9-2 Aanvulling / aanpassing - Alle talen - 18 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info