Installation Instructions
Please read these instructions carefully prior to
installation!
Installation should only be carried out by persons
qualified to do so!
Incorrect installation can put the safety of persons at
risk!
In case of improper installation, the manufacturers
guarantee becomes void.
Preparing for installation
1. To connect to the mains, a power point must be
installed on site - the included mains lead is
approx. 1 m long.
2. Check the stability of the door, retighten the
screws and nuts on the door.
3. Check that the door is running smoothly and is
in good working order, lubricate the shafts and
bearings. Check the pretension of the springs
and, if necessary, re-adjust.
4. Dismantle the existing door latches (bolt plate
and catches).
5. For garages without a second entrance, an
emergency release is required (accessory).
6. If a wicket door is included, fit the wicket door
contact.
7. Check the supplied screws and wall plugs to
ensure that these are suitable for the structural
conditions on site.
Required tools
- Drilling machine with 6 mm masonry drill
- Sturdy side cutter
- Wrench, sizes 13, 15 and 17 mm
- Slotted screwdriver, 3 mm wide
- Phillips screwdriver, size 2 x 100 mm
Choosing the installation side
Choose the installation side in accordance with the
structural conditions on site. The standard
installation side is on the right (as viewed from the
inside). For special installation situations
see 23.
Spray the track with silicone to achieve optimum
running qualities.
Fitting the toothed belt
The top door track is used for installing the drive unit.
Place the toothed belt with prefitted end clamp in the
track. Place the toothed belt in the track (back of the
toothed belt in position up)
2a Fix the end of the toothed belt in the vertical form
end piece und save it with the screw.
2b To disengage the drive wheel, actuate the lever.
Feed the toothed belt through the drive wheels of the
motor head as shown.
2c Insert drive unit with the drive wheels into the top
track.
2d Inserting the limit stop.
Position the limit stop at a distance ordering height +
50 cm from the frame under the toothed belt.
The limit stop should stop the operator approx. 5 cm
above the desired open position.
Finally, push end of toothed belt through the opening
in the end assembly angle.
Fitting the rear toothed belt fastening
3a Feed the toothed belt through the end assembly
angle and keep it taut. Slot sleeve halves, as shown
in , onto the toothed belt. Attach knurled nuts3b/3c
3d 3eand turn to tension the toothed belt by hand.
Make sure that you do not twist the toothed belt in the
process. If the toothed belt overhangs, it can be3f
shortened.
Inserting the top track roller
4a 4b+ Remove the track roller's extension ring
4c Insert the track roller into the track, adjust and
0
1
2
3
4
screw in place in accordance with the figure shown.
Fastening the door bracket
Place the door bracket on the designated drill holes
of the top door leaf section and screw down with 3
self-tapping screws 6.3 x 16.
Inserting the lifting arm
6a Slot the lifting arm onto the bolt of the motor head
and secure with clip.
6b Hold the other side of the lifting arm between the
door bracket and select hole setting (VL setting for
construction years prior to 2006).
6c Push the bolt all the way through and secure with
clip. Connect door to operator.
Sliding block
Slot the sliding block onto the track profile, push into
the rear opening on the motor head and screw down
with screw 4.2 x 13.
Mains lead cable
The back of the control unit includes a chamber ,8a
where, if required, the excess mains lead can be
stowed .8b
Connecting the coiled cable
9a At the back of the control unit there is a cable
terminal for the two individual wires.
9b Insert red wire on left (1) and green wire on
right (2) into the terminal.
Insert plug (3) into designated socket and allow9c
to engage.
Afterwards, feed the cable through labyrinth.9d
Fastening the control unit
10a Install the control unit onto the side wall. At a
distance of approx. 1m from the door and 1.50m from
the floor, mark the spot for the first plug hole, drill the
hole, insert the plug but do not screw in fully. Place
the control unit with key hole onto the screw head.
Align the unit and mark the remaining fixing10b
holes, drill holes, plug and fasten with screws
4.2 x 32.
Wall clamp
Hold up the coiled cable in a vertical position. The
maximum extension of the horizontally routed cable
may not exceed three times the original length.
Attach the wall clamp at the bend. Hold the clamp
against the wall, mark the spot, drill, plug and screw
to the wall using screw 4.2 x 45.
Connecting plan / aligning the aerial
!
: Do not connect anyInstructions
current-carrying cables, only connect volt-
free push buttons and volt-free relay
outputs.
Where door systems are used by the
public or are impulse-operated out of sight
of the door, a photocell must be installed.
E. Connection for aerial
Route the aerial on the housing exit upwards.
When using an external aerial, the shielding
must be assigned to the adjacent terminal (F, on
right) .12b
F. Connection for external impulse generator 12b
(accessories, e.g. key switch or digital coder)
G. Input STOP A
Connection for safety devices
(accessories, e.g. wicket door contact).
An interruption at this input end causes the door
to stop during the opening or closing phase or
prevents the operator from starting up in either
direction. Connection for safety devices 12c
(accessories).
5
6
7
8
9
10
11
12
H. Input STOP B
An interruption at this input end causes the
operator to automatically change direction
during the closing phase only.
Connection for 2 wire light barrier EXTRA 626
(accessories).12d
Connection for an optical closing edge
protection OSE .12e
I. Voltage supply 24 V ~
Connection can take a max. load of 100 mA
(do not exceed!).
Connection for 24V signal lamp12f
(accessories). Connection for an external
receiver (accessories).12g
J. Plug-in base for radio receiver
K. Connection for an external light, protected light
or signal lamp (protection classification II, max.
500W) (accessories).12h
P Connection for Mobility modul
Warning sticker
Place the sticker clearly visible on the inner surface
of the door.
Terminal cover and lamp shade
13a Install the terminal cover under the control
module guides.
13b Put on and latch the lamp shade from above.
Control elements
14a/b The control elements for programming the
door operator are located behind the white cover.
The cover can be opened with a screwdriver.
Once the operator has been programmed, the cover
is reclosed and serves as an interior push-button .23
A. The numerical display serves to indicate the
menu stage, the respectively set value and the
error/fault diagnosis.
a. The incremental display, lights up to indicate
readiness for operation and flashes on
acknowledgement of learned hand transmitter
codes.
B. During the setting / adjustment phase button
serves as an "UP" button and outside the menu
as a START button.
C.During the setting / adjustment phase button
serves as a "DOWN" button.
D.Button serves to call up the settings /
adjustment menu, to change the menu stages
and store the settings.
Programming the control unit is menu-driven.
Pressing button , calls up menu prompting. The
numbers displayed indicate the menu stage. After
approx. 2 seconds, the display flashes and the
setting can be altered via buttons and . The
selected setting is stored via button and the
programme automatically jumps to the next menu
stage. By repeatedly pressing the button , menu
stages can be skipped. To quit the menu, repeatedly
press button until "0" is displayed again. Outside
the menu, button can be used to generate a start
impulse.
Menu stage 1: Programming the start
function for the hand transmitter
Briefly press button . 1 is displayed. As soon as
the display flashes, press and keep pressed for
approx. 1 second the button of the hand transmitter,
with which you later wish to start the operator. As
soon as the code has been read, the red point
display (a) flashes five times before quitting. Figure 0
will be displayed. Menu finished.
13
14
15
Retain these installation, operating and maintenance instructions for the full duration of the operators service life!
GB
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Novoferm NovoPort 2016 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Novoferm NovoPort 2016 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 9,94 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info