5.1 CHARGE
It is recommended to use LiFePo4 lithium battery chargers. However, you can use a mains
battery charger for AGM/GEL batteries, checking that the maximum voltage supplied by it
does not exceed 14.5V. The charger must NOT perform any desulfation action. The use of
battery chargers for flooded lead acid batteries , although they can completely charge 3lion
batteries, they can reduce their life. If you have a configurable charger, set the CC/CV
(constant current/constant voltage) option, by setting the current value equal to or less than
0.5C, or 50A for the 3L-100, 3L-100B, 3L-100-P models, and 75A for the 3L-150-P model,
and the end--of-charge voltage value to 14.4V.
When the battery is fully charged (the display shows 100%), it is recommended that you
disconnect or turn off the charger. In the case of alternator charge, this is automatically
managed by the 3Link. In fact, 3lion batteries do not need maintenance like lead-acid
batteries.
.52 DISCHARGE
Only for models: 3L-100, 3L-100B
Do not connect equipment with power consumption greater than 100A . However,
this limit may be exceeded, provided that the following limits are met:
Discharge at constant current of 100A: 55minutes maximum *;
Discharge at constant current of 120A: 30 minutes maximum*;
Discharge at constant current of 130A: 15 minutes maximum*;
Discharge at constant current of 150A: 10 minutes maximum*;
Discharge at constant current of 175A: 1 minute maximum*;
Discharge at constant current of 200A: 10 seconds maximum*;
Only for models: 3L-100-P, 3L-150-P
Do not connect equipment with power consumption greater than 150A . However,
this limit may be exceeded, provided that the following limits are met:
Discharge at constant current of 120A: 50 minutes maximum*;
Discharge at constant current of 140A: 20 minutes maximum*;
Discharge at constant current of 160A: 15 minutes maximum*;
Discharge at constant current of 180A: 2 minutes maximum*;
Discharge at constant current of 200A: 20 seconds maximum*;
* Measurements performed at an ambient temperature of 20 °C, and starting temperature of
the lithium battery of 20 °C.