18
7. PROGRAMMING WHEN USING OWN SIM CARD
If your own SIM card is used, programming proceeds via SMS commands.
For this purpose the communication module requires network connection.
7.1 PROGRAM MODE
The battery-operated Mobeye Outdoor Alarm switches to the program
mode after re-inserting/reconnecting all batteries or holding the tag against
the reader for 5 seconds. While searching for the network connection the
outside LED flashes green and red. This process normally takes 10-30
seconds. When the network has been established the LED will first blink
green rapidly and next stay green (or flashes 1 sec. on/1 sec. off in case the
unit has not been configured yet).
In this program mode the device is ready to receive commands and settings.
A time-out occurs if no correct command is received for 3 minutes, after
which the communication module switches off in order to save the batteries.
In this low power mode the LED flashes once per 3 seconds to indicate it is
armed.
7.2 PROGRAMMING THE SETTINGS BY SMS
When using your own SIM card, the settings are programmed in by SMS
text messages:
1. Make sure the Outdoor Alarm is in program mode (please refer to 7.1).
2. Send an SMS text message with the (security) code and the command.
3. The green LED blinks 3 times to indicate the successful configuration. In
case of an incorrect command, the red LED flashes 5 times.
SMS messages have the following content: CODE COMMAND:OPTION
Example: 1111 TEL1:0044772345678
- CODE stands for the security code, factory setting is 1111.
- Do not forget the space character between (security) code and
command.
- The commands are case insensitive.