14
5. POSSIBLE SETTINGS
The Mobeye Outdoor Alarm has many setting options that influence the
behaviour of the module. If connected on the Mobeye Internet Portal, the
settings are prepared in the portal (see chapter 4). If your own SIM card is
used, programming is done via SMS commands (see chapter 6).
5.1 ALARM PHONE NUMBERS
When using Mobeye Internet Portal: an unlimited number of contacts can
receive the alarm messages. These are set in the portal.
When using your own SIM card: the Mobeye Outdoor Alarm can inform 5
telephone numbers in the event of an alarm. It is mandatory to set at least
one number (TEL1). The numbers set are used for the telephone calls and/or
SMS messages from the unit.
5.2 TEST MESSAGE
When using the Mobeye Internet Portal: The Mobeye Outdoor Alarm can
send regular test messages (keep alive) to the Mobeye Internet Portal, to
ensure the proper functioning of the unit. The test message will also be sent
if the unit is disarmed. The Mobeye Internet Portal expects the test message
and checks the timely receipt. The monitoring of the test messages follows
the ‘management by exception’ rule: only if the message was not received,
the ‘service’ contacts will receive a notification.
The timing of the test message can be programmed. Since new settings
(options) will be synchronised after the test message, setting a specific time
of the test message may help the process of remote programming. Example:
if you force a daily test message at 17.30 hrs, you can prepare new settings
and be sure they are loaded into the device before the evening.
The interval between the test messages can be set between 0 days (no test
message) and 30 days. The default test interval is set to "7" (weekly).
When using your own SIM card: The Mobeye Outdoor Alarm can send
regular test SMS messages (keep alive) to the first phone number (TEL1), to
ensure the proper functioning of the unit. The test message function is only
active if the unit is armed. The timing of the test message is determined by
the time of programming. The test time can also be set. The interval