10
can switch permanently, or just switch for a pulse time after which the
output automatically switches back (see 5.18).
The maximum load of the output O1 is 200mA. To switch devices, a relay
can be placed behind the output with an input voltage of 12VDC. The
required switching voltage of the relay depends on the device connected.
NOTE: The output does not work if the CML4275 is battery-operated.
3.7 NETWORK CONNECTION AND PROGRAM MODE
After placing the batteries (and external power) the Mobeye CML4275 will
search for the network. The outside LED flashes green and red. This process
normally takes 10-30 seconds, in a new device this can take some minutes.
When the network has been established the LED will first blink green rapidly
and next stay green (or flashes 1 sec. on/1 sec. off in case the unit has not
been configured yet).
In a battery-operated unit a time-out occurs after 3 minutes, after which the
communication module switches off in order to save the batteries. In this
low power mode the LED flashes once per 3 seconds. It will search for
network connection once it needs to send notifications. It can also been
forced to establish a network connection by re-inserting the batteries or
pressing the button for 5 seconds.
If the CML4275 is connected to an external power supply, it has continuous
network connection and is permanently in program mode.