EN 8 millnorway.com
Information requirment for the electric local space heaters
Model identifier(s): HT500
Item Symbol Value Unit Item Unit
Heat output Type of heat input, for electric storage
local space heaters only (select one)
Nominal heat output Pnom 0,5 kW manual heat charge control, with
integrated thermostat No
Minimum heat output
(indicative) Pmin 0,0 kW
manual heat charge control with
room and/or outdoor temperature
feedback
No
Maximum continuous
heat output Pmax,c 0,5 kW
electronic heat charge control
with room and/or outdoor tempe-
rature feedback
No
Auxiliary electricity
consumption fan assisted heat output No
At nominal heat out-
put elmax N/A kW Type of heat output/room temperature
control (select one)
At minimum heat out-
put elmin N/A kW single stage heat output and no
room temperature control No
In standby mode elSB 0,00038 kW Two or more manual stages, no
room temperature control No
with mechanic thermostat room
temperature control No
Seasonal space hea-
ting energy efficiency ηs 37 % with electronic room temperature
control Yes
electronic room temperature con-
trol plus day timer No
electronic room temperature con-
trol plus week timer No
Other control options (multiple se-
lections possible)
room temperature control, with
presence detection No
room temperature control, with
open window detection No
with distance control option No
with adaptive start control No
with working time limitation Yes
with black bulb sensor No
Contact details Mill International AS
Grini Næringspark 10, 1361 Østerås, Norway