Gas installation must be made in accordance with AS5601;
Also refer to rangehood manufacturers recommendation.
Check gas presure, note the correct setting from the data
plate sealed inside the front appliance drawer *.
Stability bracket
WARNING: In order to prevent accidental tipping of the
appliance, for example a child climbing onto the open oven
door, the stabilising means must be installed.
Note: If the wall plug provided is not suitable for the wall
material please use an appropriate device to ensure secure
holding of the "screw" to the wall.
Installing the gas cooker:
(Flexible connection are NOT supplied with this appliance)
- An inlet manifold extension pipe must be fitted to the
appliance. Part supplied in the drawer of the appliance.
- Ensure that the pipe is connetted using the washer
provided and that the braket is screwed to the appliance
as shown in the diagram below.
- Fit the supplied pressure regulator (for Natural gas) using
the NG test piont adaptor and washer to the inlet manifold.
Ensure the arrow is pointing towards the appliance and
that pressure testpoint is accessible from the final
position.
- Push the cooker back and install the stabilizing chains.
- Connect the appliance inlet manifold to the consumer
piping outlet using only fixed piping. This final connection
is made when the product is pushed back into position by
access under the cooker.
The hose assembly
- must comply with AS/NZS 1869 Class B or D,
- be of appropriate internal diameter and be kept as short as
possible (less than 1,2 mm)
Fig. B Fig. C
GAS CONNECTION
- It must not be kinked
- It must not be in contact with hot surfaces.
IT IS RECOMMENDED THAT A SERVICE TAP AND UNION BE
FITTED ADJACENT TO THE APPLIANCE INLET TO
FACILITATE FUTURE SERVICING.
5 burner models: set the burner pressure to 1kPa for Natural
Gas and 2.75kPa for U-LPG with the wok burner operating a
full rate'. For commissioning of the appliance with the
regulator for Natural Gas, the test point pressure should be
1.00kPa with all burners operating on HIGH.
Apply a manometer to the test nipple and reset the regulator
if necessary. Do not forget to replace the test nipple screw
and to leave the instructions book with the user.
VERY IMPORTANT FOR THE INSTALLER
Do not attempt to turn or stress threaded elbow of the
manifold: you risk damage to this part of the gas appliance
which may void the manufacturers warranty.
Before Leaving – Check all connections for gas leaks.
DO NOT use a naked flame for detecting leaks. Ignite all
burners to ensure correct operation of gas valves, burners
and ignition. Turn gas taps to low flame position and
observe stability of the flame.
When satisfied with the cooker, please instruct the user on
the correct method of operation.
In case the appliance fails to operate correctly after all
checks have been carried out, refer to the authorised
service provider in your area.
GAS CONVERSION AND ADJUSTMENT
When used with natural gas all burners have been preset at
our factory and further adjustment should not be
necessary. Conversion kits to other gases are available
from the place of purchase. Do not attempt to fit the
conversion kit yourself. Conversion to U-LPG gas should
only be carried out by an authorized technician.
GAS ADJUSTEMENTS
- change the injectors
- adjust the minimum flow
‘When conver ting from Natural Gas to U-LPG ensure that
the NG regulator is removed and replaced with the Test
Point Assembly. A gas regulator suitable for a supply
pressure of 2.75kPa should be part of the gas tank supply
and should be adjusted with the wok burner operating at
maximum.
REPLACEMENT OF THE INJECTORS
When required to operate on other gas replace the
injectors in accordance with information referred to in chart
below.
A test point fitting must be
installed between the piping and
the appliance for the pressure to
be checked to ensure it is
operating for ULPG at 2.75 kPa.
Be aware that the appliance has
two gas inlets (L/R). Before
performing the leakage test
select which side will be the
connection point and cap and
pressure test the side that will not
be used.
A test point fitting must be
installed between the piping and
the appliance for the pressure to
be checked to ensure it is
operating for NATURAL GAS at 1
kPa.
Be aware that the appliance has
two gas inlets (L/R). Before
performing the leakage test select
which side will be the connection
point and cap and pressure test
the side that will not be used.
Pressure regulator for natural
gas
Pressure tst point for ULPG
Wall Fixing
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Midea 36SME5GFQ00P48 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Midea 36SME5GFQ00P48 in de taal/talen: Engels als bijlage per email.

De handleiding is 8,05 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info