11 [EN]
Sleep
1. This mode can only be activated when the portable air conditioner is in Cool or Heat mode.
2. The portable air conditioner will run on Low Fan Speed only to reduce the noise level.
3. In Cool Mode: After 1 hour the pre-set temperature is increased by 1°C, after another hour the
pre-set temperature will increase by another 1°C. The temperature is kept constant for 10
hours.
4. The LED display will dim.
Heat (only available on CH models)
1. Press the Mode Button until the LED light next to Heat on the display appears.
2. Press the Up and Down arrows to adjust the temperature displayed. The temperature can be
set between 16°C and 32°C. The portable air conditioner will run until the desired temperature
is reached. If the temperature in the environment drops below the target temperature, the
portable air conditioner will automatically come back on.
Please Note: The compressor will stop working straight away however the fan may continue to
run if the coil pipe temperature is detected to be above 34°C. The fan will stop running once
the coil pipe temperature reaches 34°C or below.
3. Press the Fan Speed Button to change the fan speed between High, Middle and Low. An LED
light will appear on the display indicating the chosen fan speed.
4. To control the direction of air flow horizontally, adjust the inner louver from left to right manually.
5. The drainage hose should be attached for continuous operation (see pages 13 and 14).
6. The supply air fan will run continuously, blowing hot air out the front of the portable air
conditioner. The exhaust air fan, blowing hot air out the back of the portable air conditioner, will
turn on periodically as required. In certain conditions, depending on the temperature and
humidity level, the exhaust air fan will run continuously. Both situations are normal operation.
Other Functions
---------------------------------------------------------------------------------------------------------------------------------------
Timer
The timer has two modes of operation and can be set anywhere between 1-24 hours: Off Timer and On
Timer.
• To set the Off Timer, when the portable air conditioner is turned on, press the Timer Button.
Use the Up and Down arrows to set the number of hours in which you want the portable air
conditioner to turn off.
• To set the On Timer, when the portable air conditioner is turned off on the display (but there is
power to the machine), press the Timer Button. Use the Up and Down arrows to set the number
of hours in which you want the portable air conditioner to turn on.
• To remove any set timers, press the Up or Down arrow until the display shows ‘00’. When the
power is turned off, all set timers will be lost.