785594
7
Verklein
Vergroot
Pagina terug
1/8
Pagina verder
USER’S MANUAL
MasterBus FireCAN
Interface
Interface from MasterBus to FireCAN
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Fax.: +31-20-6971006
www.Mastervolt.com Copyright © 2016 Mastervolt
10000011042/04
ENGLISH: PAGE 1
2
April 2016 / MasterBus – FireCAN Interface / EN
1 GENERAL INFORMATION
1.1 USE OF THIS MANUAL
Copyright © 2016 Mastervolt. All rights reserved.
Reproduction, transfer, distribution or storage of part
or all of the contents in this document in any form
without the prior written permission of Mastervolt is
prohibited.
This manual serves as a guideline for the safe and
effective operation of the MasterBus FireCAN
Interface, to be called FireCAN Interface further in
this manual.
Keep this manual at a secure place!
1.2 GUARANTEE SPECIFICATIONS
Mastervolt guarantees that this product was built
according to the legally applicable standards and
stipulations. If you fail to act in accordance with the
regulations, instructions and stipulations in this
user’s manual, damage can occur and/or the product
will not fulfil the specifications. This may mean that
the guarantee will become null and void.
1.3 LIABILITY
Mastervolt can accept no liability for:
consequential damage due to use of the FireCAN
Interface;
possible errors in the manuals and the results
thereof;
Use that is inconsistent with the purpose of the
product.
CAUTION!
Never remove the identification label.
1.4 CORRECT DISPOSAL OF THIS PRODUCT
(Waste Electrical & Electronic Equipment)
This product is designed and manufactured with high
quality materials and components, which can be
recycled and reused. When this crossed-out
wheeled bin symbol is attached to a product, it
means the product is covered by the European
Directive 2012/19/EU.
Please be informed about the local separate
collection system for electrical and electronic
products.
Please act according to your local rules and do not
dispose of your old products with your normal
household waste. The correct disposal of your old
product will help prevent potential negative
consequences to the environment and human
health.
2 HOW IT WORKS
2.1 COMMUNICATION
The FireCAN Interface forwards MasterBus
information to the FireCAN network.
The information of one battery charging device will
be shared on the FireCAN network. The battery
charging device can be a battery charger or a
charger/inverter combination(Combi).
If your MasterBus network has only one charging
device and the interface is in “Auto” mode, the
FireCAN interface will automatically start
communicating the data of this device and not
require any configuration.
By default the value “Auto” mode is on.
EN / MasterBus – FireCAN Interface / April 2016 3
3 CONFIGURATION
This interface can be configured via MasterBus on the Configuration page. Configuration is done on a MasterView
display or via MasterAdjust PC software.
3.1 LANGUAGE & DEVICE NAME
The language and the device name can be configured in the General group.
The table 1 shows the general MasterBus configuration.
Configuration page Default
GENERAL
Language Set the FireCAN Interface menu language English See specifications
Name Any name with 12 characters max INT FireCAN 12 characters max
Table 1: Setup of Device configuration
Figure 1: General configuration in MasterAdjust
4
April 2016 / MasterBus – FireCAN Interface / EN
3.2 FIRECAN
In the FireCAN group on the configuration page you
can configure the FireCAN settings. When the “Auto”
checkbox (see figure 2 (a)) is activated the
configuration is done automatically. Otherwise the
configuration has to be done manually.
Use Auto configuration when you have a MasterBus
network with only one charging device
If you have more than one charger and want to
transmit information of all chargers you will need to
use one FireCAN interface for each charging device.
3.2.1 Auto configuration
In Auto configuration the FireCAN will find a
charging device on the MasterBus and set the
configuration parameters accordingly. Table 2.
shows all the possible charging devices.
Charging devices Article number
Mass Combi Ultra 12/3000 38013000
Mass Combi Ultra 24/3500 38023500
Mass Combi Ultra 48/3500 38043500
Mass Charger 24/15-2 40020156
Mass Charger 24/25-2 40020256
Mass Charger 24/25-2 DNV 40720266
Mass Charger 24/50-2 40020506
Mass Charger 24/75 40020756
Mass Charger 24/100 40021006
Mass Charger 24/50-3ph 40031010
Mass Charger 24/100-3ph 40031006
Mass Charger 48/25 40040256
Mass Charger 48/50 40040506
Serial interface with
Mass Combi 77030450
Combi interface with
Mass Combi 77030475
ChargeMaster 12/25-3 44010250
ChargeMaster 12/35-3 44010350
ChargeMaster 12/50-3 44010500
ChargeMaster 12/70-3 44010700
ChargeMaster 12/100-3 44011000
ChargeMaster 24/12-3 44020120
ChargeMaster 24/20-3 44020200
ChargeMaster 24/30-3 44020300
ChargeMaster 24/40-3 44020400
ChargeMaster 24/60-3 44020600
ChargeMaster 24/80-3 44020800
ChargeMaster 24/100-3 44021000
Table 2: Overview of charging devices recognized in
Auto mode
The configuration parameters can be viewed but not
changed in Auto mode. The automatic configuration
will always choose the default Node ID of 16 for the
FireCAN network. If you have more than one
charger and want to transmit information of all
chargers you will need to use a sequence of Node
ID’s on the FireCAN network..
A new charging device will be selected when the
selected device is not responding.
3.2.2 Manual configuration
In Manual configuration (“Auto” not activated) you
have to make all the configurations yourself.
The easiest way is to use MasterAdjust,
see Figure 2 for more details. Some data fields
require you to enter an index. See paragraph 3.5 on
getting this information from MasterAdjust.
A quick way of only configuraring 1 charger
in a Masterbus network with multiple
charging devices is;
1. Connect only one Charging device, by
removing the other devices from the
MasterBus.
2. Select Auto, and wait until the
configuration is automatically made
for the Charging Device.
3. Uncheck the Auto mode, which
prevents the FireCAN interface from
switching to another Charging Device.
4. Reconnect the other Charging
Devices.
EN / MasterBus – FireCAN Interface / April 2016 5
a
c
b
d
f
e
Figure 2: FireCAN Interface configuration example and explanation
FireCAN Configuration
a. If Auto is selected all other settings in this group are set automatically.
b. Select the Node ID on the FireCAN network.
c. Select the Charging device of which the data will be shared on the FireCAN
network
d. The FireCAN interface will read the battery voltage from this index on the
monitoring page of the charging device
e. The FireCAN interface will read information about the Grid availability from
this index on the monitoring page of the charging device.
f. The Grid will show “On” whenever the following expression is true:
Information from (e.) combined with selected logic (f.) and threshold (g.)
g. Select the threshold to be used in the expression evaluation of (e & f.). For
example: if grid index points to a field which shows a value of 230V input
voltage shown on the charger, and “Grid on if” is set to “larger than” you can
select a threshold of 115V. If the Grid voltage is larger than 115 the Grid will
be shown on the FireCan as Available.
h. If the expression as described in (f.) is NOT true, the grid will show state as
selected here.
i. Choose if the FireCAN interface will read and transmit information about the
charging current of the charging device
j. The FireCAN will read the charging current output of the charging device
from this index. This is the index on the monitoring page
k. Choose if the FireCAN interface will read the alarm status for “Battery
Voltage High”
l. The FireCAN will read the status of “Battery Voltage High” from this index.
This is the index on the Alarm page.
m. Choose if the FireCAN interface will read the alarm status for “Battery
Vlt L
g
h
i
j
k
l
m
n
6 April 2016 / MasterBus – FireCAN Interface / EN
3.3 INFORMATION TRANSMITTED ON
FIRECAN
The following information is transmitted on the
FireCAN network:
Grid availability: Information about grid availability
is shared on the FireCAN network. This information
is determined by applying some logic. See Figure 1.
E/F/G/H for more information.
Charging status. The charging status will output
ON if:
“Read charging current” is selected and the
charging current is larger than 0.05A.
Charging will output OFF if:
“Read charging current” is selected and the
charging current is lower than 0.05A or
If “Read charging current” is not selected and
there is no “Grid available”
Charging will output Unavailable when none of the
above criteria are met.
Charging complete will always output Unavailable;
as this information can never be guaranteed. For
example a loose battery connection or a blown fuse
can give the impression of a battery not accepting
current and indicating a complete charge.
Battery voltage read from the charging device.
High voltage alarm.
High voltage alarm will output ON if
the “Read high alarm” is selected and the alarm
at high alarm index is ON (or 1) or if
“Read high alarm” is not selected and the
“Battery voltage” is between 15 and 18V or is
above 30V.
The High alarm status will output OFF if:
the “Read high alarm” is selected and the alarm
at high alarm index is OFF(or 0)
High alarm will output Unavailable in all other cases.
Low voltage alarm works in the same manner as
the High voltage alarm. The voltage window is below
10V and between 18 and 20V.
3.4 FAULT CODES
The last 10 fault codes are saved in the FireCAN
interface. These codes can be reviewed via
MasterBus and via the FireCAN network.
Every new fault is stored in location 1, the codes
move one position up. When there are more than 10
faults location 10 is lost.
Possible Fault codes:
501: Indicates a low voltage of the battery. This
fault is logged when the charging device shows a
low voltage alarm.
502: Indicates an over voltage on the battery.
Also indicated by an alarm of the charging
device.
All 10 fault code locations can be reset via the
FireCAN network.
3.5 EXAMPLE OF FINDING INDEX OF FIELD
A Index number can be found by hoovering your
mouse pointer over a data field in the monitoring
page or alarm page.
In figure 3 an example is shown on how to find the
index of a specific data field
Figure 3:
MasterAdjust reveals the Index number of a
valiable when hoovering over it.
EN / MasterBus – FireCAN Interface / April 2016 7
4 INSTALLATION
See figure 4 for the FireCAN Interface connections.
5 SPECIFICATIONS
Model: MasterBus – FireCAN interface
Article number: 77032400
Delivery also includes: FireCAN cable (length: 100mm), MasterBus Terminating device, User’s manual
Function of instrument: Interface between MasterBus and FireCAN
Languages available: English, Nederlands, Deutsch and Français
Current consumption: <40 mA
MasterBus Powering: No
Din rail mounting: Yes, Din rail 30 mm [1.2 inch]
Protection degree: IP 21
Dimensions: 66 x 78 x 32 mm [2.6 x 3.1 x 1.3 inch]; see drawing below
Weight: Approx. 70 gr [0.15 lb] excluding cable
Maximum units 5 (Maximum number of MasterBus to FireCAN interface in one FireCAN network )
Figure 5: Dimensions in mm [inch]
1. CAN_High
2. CAN_Low
3. CAN_Ground
4. Communication LED
for MasterBus and
FireCAN
MasterBus
4
1 2 3
MasterBus network MasterBus network
Figure 4:
Overview of the
FireCAN Interface
FireCAN network cable
Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands
Tel : + 31-20-3422100
Fax : + 31-20-6971006
Email : info@mastervolt.com
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Mastervolt MasterBus FireCAN Interface bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Mastervolt MasterBus FireCAN Interface in de taal/talen: Engels als bijlage per email.

De handleiding is 0.19 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info